Showing results: 2986 - 3000 of 4341 items found.
-
42-876A-102 -
Pickering Interfaces Ltd.
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-876A-102 -
Pickering Interfaces Ltd.
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-002 -
Pickering Interfaces Ltd.
The 40-876A-002 (PXI) and 42-876A-002 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-004 -
Pickering Interfaces Ltd.
The 40-876A-004 (PXI) and 42-876A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-104 -
Pickering Interfaces Ltd.
The 40-876A-104 (PXI) and 42-876A-104 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-158-003 -
Pickering Interfaces Ltd.
The 40/42-158-003 is a PXI/PXIe high density power relay module with 16xSPDT switches rated at 5A. User connection is via a 50-pin SGMC male connector. The 40/42-158 range is available in 8, 16, 24 or 32 SPST configurations with or without hardware interlock. Electro-mechanical power relays are used which are suitable for switching loads up to 5A at 250VAC.
-
Pickering Interfaces Ltd.
Pickering's high-density PXI large matrix BRICs offer current handling up to 1 Amp and select models are supported by our Diagnostic Test Tools, Built-In-Relay-Self-Test (BIRST) and eBIRST Switching System Test Tools, these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.
-
780587-44 -
NI
PXIe, 6.6 GHz, 50 Ω, Solid-State, 8x1 PXI RF Multiplexer Switch Module—The PXIe‑2544 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
777754-01 -
NI
16-Channel, 7 A, SPST PXI Relay Module—The PXI‑2565 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. It delivers high-current switching of DC power supplies, AC line power, and AC/DC current sources. The PXI‑2565 is fully software programmable and supports multiple instrument synchronization.
-
ATE Systems
ATE Systems has developed a wide variety of custom test systems that integrate commercial test instruments and custom hardware, tied together with a test executive. Examples of the types of tests that have been incorporated include: S-parameters (gain, return loss, VSWR, etc), Noise figure, Power, Spectral response, Linearity, Voltage, Current, Switching speed and so on
-
Power Diagnostix Systems GmbH
Partial discharge testing – well established for high voltage equipment – becomes increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized solutions for automated and semi-automated testing.
-
34921A -
Keysight Technologies
The Keysight 34921A module for the 34980A Multifunction Switch/Measure Unit is the most versatile multiplexer for general purpose scanning. It has low thermal offset characteristics and a built-in thermocouple reference on the terminal block, making it ideal for temperature measurements directly to the internal DMM. The dense, multi-function switching with 100 channel/second scan rates addresses a broad spectrum of data acquisition applications.
-
TOELLNER-wavecontrol -
Toellner Electronic Instrumente GmbH
The Software TOELLNER-WaveControl provides waveforms and controls the TOELLNER system components at the test station, which can be individually tailored to your requirements. Using a DAQ-Card, any signal waveform can be provided with Arbitrary Power Supplies or 4-Quadrant Amplifiers with outputs from 160 W to 5200 W. For fast interruptions, TOELLNER offers electronic switches with switching times below 500 ns.
-
778572-43 -
NI
6.6 GHz, 50 Ω, Solid-State, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2543 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
778572-44 -
NI
6.6 GHz, 50 Ω, Solid-State, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2544 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.