  • Multiport Electromechanical Coaxial Switch, DC to 40 GHz, SP4T

    87104D - Keysight Technologies

    The Keysight 87104D multiport switch improves signal accuracy in RF and microwave signal routing and testing applications. This high performance electromechanical switch provides unmatched isolation and a 0.03 dB insertion loss repeatability, which is warranted for the 5-million life cycle of the switch. The 87104D’s low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy. The repeatability and reliability of this switch guarantee measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications.

  • Multiport Coaxial Switch, DC to 4 GHz, SP4T

    87104A - Keysight Technologies

    The Keysight 87104A multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87104A terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.

  • Multiport Coaxial Switch, DC to 26.5 GHz, SP4T

    87104C - Keysight Technologies

    The Keysight 87104C multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87104C terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.

  • Multiport Coaxial Switch, DC to 4 GHz, SP6T

    87106A - Keysight Technologies

    The Keysight 87106A multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87106A terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.

  • Multiport Electromechanical Coaxial Switch, DC to 40 GHz, SP6T

    87106D - Keysight Technologies

    The Keysight 87106D multiport switch improves signal accuracy in RF and microwave signal routing and testing applications. This high performance electromechanical switch provides unmatched isolation and a 0.03 dB insertion loss repeatability, which is warranted for the 5-million life cycle of the switch. The 87106D’s low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy. The repeatability and reliability of this switch guarantee measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications.

  • Multiport Coaxial Switch, DC to 20 GHz, SP6T

    87106B - Keysight Technologies

    The Keysight 87106B multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87106B terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.

  • Multiport Coaxial Switch, DC to 20 GHz, SP4T

    87104B - Keysight Technologies

    The Keysight 87104B multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87104B terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.

  • 78 Pin D-type Connector & Cable Accessories

    Pickering Interfaces Ltd.

    The Standard Voltage 78 Pin D-Type connector is used on PXI and LXI switching products to provide a medium density user connector solution. If you would like to develop your own cabling solutions, we offer mating connectors and connector hoods that allow you to create either your own cable based solutions, or a PCB header solution. Connector Blocks directly terminate the module connector and convert the connection to arrays of screw terminal blocks, or you can select to use a remote DIN rail mounted breakout to terminate the cables at the end of a cable assembly. You can also try our Cable Design Tool to graphically design a customized cable assembly.

  • PXI 18 Bank, 3 Channel, 1 Pole Multiplexer

    40-617-021 - Pickering Interfaces Ltd.

    The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. Inter-bank linking relays allow multiplexer size to be increased in multiples of 3 by joining the common terminals of adjacent banks. Closing one linking switch produces a 6 channel multiplexer, closing all linking switches produces an 54 channel multiplexer.

  • RF Amplifier

    SA1012 - Hangzhou Softel Optic Co., Ltd.

    *Forward path use import low noise push pull amplify module or GaAs push pull module,2 Power-Double module or GaAs amplify module are used as output stage, Output level is stable and nonlinear index is good, import high index amplify module are used on return path, It's distortion is little and SNR is high.*It is more convenient to debug because of plug-in(or adjustable) duplex filters, plug -in fixed(or adjustable)equalizers, plug-in output splitters and scientific and rational on-line detection ports.*The equipment can work steadily outdoor under bad environmental condition because of waterproof aluminum case, high reliability switching power supply and lightning protection system.

  • RF Amplifier

    SA1022 - Hangzhou Softel Optic Co., Ltd.

    *1000MHz Broadband RF signal amplifier, Line extender, RF amplifier GaAs MMIC used on the forward path, Power-Double module amplify module are used as output stage, Output level is stable and nonlinear index is good, import high index amplify module are used on return path, its distortion is little and SNR is high.*It is more convenient to debug because of plug-in (or adjustable) duplex filters, plug -in fixed (or adjustable) equalizers, plug-in output splitters and scientific and rational on-line detection ports.*The equipment can work steadily outdoor under bad environmental condition because of waterproof aluminum case, high reliability switching power supply and lightning protection system.

  • AC Power Sources

    BPS Series - AMETEK Programmable Power, Inc.

    The BPS Series consists of multiple high power AC power systems that provide controlled AC output for ATE and product test applications. This high power AC test system covers a wide spectrum of AC power applications at an affordable cost. Using state-of-the-art PWM switching techniques, the BPS Series combines compactness, robustness and functionality in a compact floor-standing chassis, no larger than a typical office copying machine. This higher power density has been accomplished without the need to resort to elaborate cooling schemes or additional installation wiring. Simply roll the unit to its designated location (using included casters), plug it in, and the BPS Series is ready to work for you.

  • 2-Slot BRIC, 256x4, 1Pole, PXI Matrix (2 Sub-cards)

    40-559-201-256x4 - Pickering Interfaces Ltd.

    This range of BRIC ultra-high-density large PXI matrices are available in 2, 4 or 8-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays. With their high level of switching density, these PXI matrices allow a complete Functional ATE system to be housed in a single 3U PXI chassis and allow the use of much lower cost 8 or 14-slot chassis. The 40-559 matrices can be used in many industries; typical applications include automotive ECU and semiconductor package testing. Dual analog busing for the narrower matrix options, enable completely separate matrices within a single module for parallel testing.

  • 0 Hz/DC to 14 GHz, Single-Pole, Four-Throw MEMS Switch With Integrated Driver

    ADGM1304 - Analog Devices Inc.

    The ADGM1304 is a wideband, single-pole, four-throw (SP4T) switch, fabricated using Analog Devices, Inc., microelectro-mechanical system (MEMS) switch technology. This technology enables a small, wide bandwidth, highly linear, low insertion loss switch that is operational down to 0 Hz/dc, making it an ideal switching solution for a wide range of RF applications. An integrated control chip generates the high voltage necessary to electrostatically actuate the switch via a complementary metal-oxide semiconductor (CMOS)-/low voltage transistor-transistor logic (LVTTL)-compatible parallel interface. All four switches are independently controllable. The ADGM1304 is packaged in a 24-lead, 5 mm × 4 mm × 0.95 mm lead frame chip-scale package (LFCSP).

  • Digital mammography system

    AMULET - FujiFilm Corp.

    The new format FPD has a proprietary panel structure with a double layer of amorphous selenium that has high X-ray absorption properties, and was developed by combining Fujifilm''s "Device Development Technology" and "Vacuum Deposition Technology." The first layer efficiently converts X-rays into electrical signals, while the second layer employs the unique "Direct Optical Switching Technology," that captures higher resolution and lower noise image electrical signals rather than using electrical switches such as conventional TFTs. By achieving both "50µm fine pixel size (higher resolution) and low noise," the AMULET system can show microcalcifications and tumors in greater detail, both significant indicators for early diagnosis of breast cancer.