Showing results: 3316 - 3330 of 4319 items found.
-
40-411-001 -
Pickering Interfaces Ltd.
The 40-411 is the perfect solution for driving external relays from a PXI system or from Pickering Interfaces LXI modular chassis. Each module provides 64 channels of low side switching for external relays. Users need to simply connect a positive voltage source to one side of the relay coil and the other side to the 40-411 output. Each output is capable of sinking up to 1 Amp of continuous current.
-
CSTN -
RARA Electronics Corporation
*Thin film process*High power rating up to 3 watts in 2512 size*Resistance values from 50m to 1ohm*High purity alumina substrate for high power dissipation*Power management applications*Switching power supply*Over current protection in audio applications*Voltage regulation module (VRM)*DC-DC converter, battery pack, charger, adaptor,*Automatic engine control*Disk drive
-
40-516-002 -
Pickering Interfaces Ltd.
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
Aero Nav Laboratories, Inc.
The dielectric withstanding voltage test (also called high-potential, over-potential voltage-breakdown, or dielectric-strength test) consists of the application of a voltage significantly higher than rated voltage for a specific time, between mutually insulated portions of a component part or between insulated portions and ground. This is used to prove that the component part can operate safely at its rated voltage and withstand momentary over-potentials due to switching, surges, and other similar phenomena.
-
CP500 -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP150 -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP150-6M -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP031 -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP030 -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP030-3M -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP031A -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP030A -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Hilkar
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
WGMD-60 2D -
Langeo Co., Ltd.
WGMD-60 geo-electrical 2D electrical tomography device is the new developed two-dimention electrical resistivity imaging (ERT) system, which integrated electrode switching and 200v transmitting high power in the mainframe. It support max 60 electrode switching.The whole system features light weight and high stability. It widly applys for different resistivity mapping or geopysical surveys as landslide survey, groundwater investigation, enginnering exploration and so on.
-
Model T400 -
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.