Bulk Current Injection
-
Product
8 SE Or 4 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-8-4C
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
Current Logger Sensor
NUL-202
-
This sensor can be used to measure the current in parallel or series branches of low voltage AC and DC circuits and also to investigate the dependence of the current flow through components on the voltage across them.
-
Product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
43-752A-911
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
AC/DC Current Probe, 100 MHz, 15A
N2893A
Oscilloscope Probe
The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.
-
Product
3KVA Leakage Current Tester
2675C3
-
Shenzhen Chuangxin Instruments Co., Ltd.
3KVA Leakage Current Tester
-
Product
Split type AC Current Sensor
CTF-100A
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
* Suitable for current measurements of feeder. * Wire stopper is equipped for the slipping protection. * The special connector is not necessary as the output terminals are provided. * Open circuit protection and nonflammable plastic material.
-
Product
12-Ch SPST 5A-250VAC High Current Power Switching
YAV90CIN
Switch Module
12 Independent SPST relaysSwitching up to 5A 250Vac12 current measurement channelsGeneral inhibit inputCAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
AC Current Sensor
LFR
-
The LFR ac current probe has been designed to have market leading low frequency performance, meaning low phase shift and low noise. This compact, low cost, clip-around probe is both flexible and dual-range, and is optimized to give minimal phase measurement error at frequencies from 45Hz to 20kHz and have a very low noise floor.
-
Product
Clamp type AC Current Sensor/for Power Monitor
ZCT-33S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra compact size*AC 0.1A~150A*Current measurements of feeder
-
Product
150A, 12 MHz CURRENT PROBE, BNC, AC/DC, 150A rms, 300A Peak Pulse
T3CP150-12
-
150A, 12 MHz CURRENT PROBE, BNC, AC/DC, 150A rms, 300A Peak Pulse.
-
Product
High Current Switches
-
Marvin Test Solutions’ switch card portfolio includes matrix, multiplexer, and RF multiplexer configurations. 3U and 6U PXI switch cards feature easy to use, reliable, and integration-friendly D-sub style interface connectors – a feature unique to Marvin Test Solutions PXI switch cards. GENASYS switch cards are compatible with MTS’s family of GENASYS Switching and Switching/Digital Subsystems, featuring integrated MAC Panel SCOUT receivers.
-
Product
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)
ZCT-80
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Leakage current measurements of main cable*BIG CT WINDOW*AC 1mA~500A
-
Product
DC Current Shunts
-
DC current shunts / standards are true 4-terminal devices that precisely measure DC currents from 10 A to 10,000 A. They use special alloys in the resistive elements which are supported on an insulating base for mechanical stability. The 9230A includes special features to reduce the effects of power dissipation and associated self heating errors. These shunts are designed to operate in air at full rated current. These are the best performing, and most widely used, DC metrology shunts in the world.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 24-Channel, 1-Pole
42-514-108
Multiplexer Module
The 40-514-107 (PXI) and 42-514-107 (PXIe) are low density multiplexers in dual 12-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Split type Pulse Current Sensor
OKM-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For pulse current detection.
-
Product
Current Sensing
-
A current sense amplifier is a differential amplifier providing an analog output voltage proportional to the current flowing into a load connected on its input.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
4-20mA Current Loop USB Data Logger
EL-USB-4
-
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
Product
Current Transformers And Shunts
-
Current transformers allow the different measuring devices to provide reliable and traceable data on the trends involving consumption and production processes in electrical installations. Especially designed to be installed quickly, easily and securely, meeting the most demanding expectations of today's market, covering a wide range of primary currents as well as multiple secondary outputs, both for AC and DC measurement.
-
Product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
Product
High Voltage Surge Current Monitors
HVSCM
-
Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.
-
Product
Epoxy Injecting Machine - EIM-280
-
Shanghai Fibretool Technology Co.,Ltd.
1, Injecting Epoxy Adhesive into ceramic ferrules for fiber optic connectors.2, High Accuracy to control epoxy dosage.3, Easy to adjust output pressure and injecting time.4, With hand touch switch and foot switch.5, Compact for production line.
-
Product
PXI/PXIe Wide Current Range Matrix Module, 6x4, 2-Pole, X & Y Loop-thru
42-514-002
Matrix Switch Module
The 40-514-002 (PXI) and 42-514-002 (PXIe) are low density matrices in 6x4 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
42-514-105
Multiplexer Module
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Split type Pulse Current Sensor
CTF-05T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For detecting current pulse with open collector output (for power pulse)
-
Product
High Current Discharge Testing System
DTV
-
Cold Crank Testing to industry standards: IEC, SAE, BCIDischarge capacity performance testing to thousands of amperes
-
Product
Eddy Current Dynamometer
EC Series
-
Specifically designed for small displacement diesel engines, the Eddy Current (EC-Series) engine dynamometer features in-line eddy current absorption units in a robust, compact frame. The air-cooled eddy current absorbers eliminate the need for an expensive water recirculation system and most engines being tested can be cooled with a standard closed-circuit radiator system. This compact air-cooled design results in a minimal environmental impact and the ability to be easily relocated with no need for a permanent installation. When combined with PowerNet LT, our fully automated dynamometer control system, all of your testing needs can be performed at the touch of a button.
-
Product
High Current DC Transformerd
-
High Current DC Transformer provides very accurate DC current measurements up to 3000 A with output current that varies directly with the input current in three ranges. This direct current transformer is designed with an open window to pass a single cable, set of cables, or buss bar that carry the direct current to be measured.
-
Product
Software for Current & Water Quality Monitoring Data Analysis
DataStudio 3D
-
Aanderaa, a Xylem brand, is a technology provider of oceanographic sensors, instruments and systems which are able to measure environmental parameters such as wave, current andwater quality (Dissolved Oxygen, Salinity, Temperature, Depth and Turbidity) over long deployments, several years.Data analysis is an important stage in all environmental monitoring campaigns. In many situations, users have to download and filter through large data quantities for analyses. DataStudio3D is a free data analysis software available to Aanderaa SeaGuard and SmartGuard users.To aid in data analysis, Aanderaa has developed their own propriety software, DataStudio3D which allows users to download field data and plot them on different graphical plots. This mode of data analysis can be carried out within minutes to help user to compare parameters, view trends, anomalies, and to control the data quality.





























