Ground Strap
-
product
Automated Digital Ground Continuity Tester
Educated Design & Development, Inc.
1 Button Testing - No setup required, just plug right in!Digital LED display reads out in OhmsAlso performs the Low Current Ground Continuity test, at the same time!Auto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchCustom universal receptacle accepts both 120V and 240V plugs.Zero feature allows you to "zero-out" the test lead impedance.Meets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements.
-
product
6U VPX 4 Slot Power & Ground
101VPX604P-1X40R
Power for 3.3V, 5V and 12V are included, rear connectors areall fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Leakage Current Tester and Clamp-On Earth / Ground Resistance Tester
10µA Ultra High ResolutionLarge Conductor Diameter (30mm)AC Current in 5 Ranges (40mA, 400mA, 4A, 40A, 60A)Wide Frequency Response (40Hz-1KHz)ACA, ACV, Ω and ContinuityLarge 3¾ Digit LCD (4000 Count)40 Segment Fast Bargraph Display (20 times/sec.)Data Hold and Max / Min HoldRelative Measurement600 Vrms Overload Protection in Resistance Range
-
product
5mA High Accuracy Ground Fault Detector
HA-GFD
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
product
Earth Ground Clamp Meter
T2000
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
product
6U VPX 1 Slot Power & Ground 10G Pass Through
101VPX601P-9X12R
Power for 3.3V, 5V and 12V are included, rear connectors areall fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
Service Ground Test Set
900
TESCO’s Service Ground Test Set has been designed to check the condition of the ground connection on a secondary service. If for any reason the ground connection has a resistance, this can be immediately detected by the Test Set. The Service Ground Test Set consists of a voltmeter which can be shunted by a resistance of 60 ohms. The voltmeter is of the suppressed zero type with a double range, from 65 to 130 or from 130 to 260, and can be used for checking service voltage independently of the ground test.
-
product
Ground Set Tester
Self-contained, portable convenienceThis tester provides an easy way for an electric utility to check the resistance in protective grounding sets used by line personnel.
-
product
Personal Grounding Tester
PGT120
Electronic test apparatus for checking personnel grounding systems such as electrostatic wrist straps and conductive footwear. The unit is equipped with two separate measuring circuits and is therefore capable of checking wrist straps and footwear separately or in parallel. The test result is signaled visually, acoustically (only if error is detected) and via contacts.
-
product
AIR SURVEILLANCE AND GROUND BASED AIR DEFENCE
GIRAFFE AMB
The system monitors the air volume 360 degrees for air targets and simultaneously locates and warns against incoming rocket, artillery and mortar rounds, and at the same time able to provide coastal surveillance.
-
product
7U VPX 4 Slot Power & Ground 10G Pass Through
101VPX704P-9X12R
Power for 3.3V, 5V and 12V are included, rear connectors areall fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
ATEX / FM Approved Grounding Clamps, Cables and Reels
Cen-Stat Static Grounding Clamps
Static grounding systems like the Earth-Rite range combine interlock control and visual indication to verified ground connection points and offer the highest levels of protection over electrostatic ignition risks. However, equipment specifiers may select passive grounding devices, like single pole clamps, to ground and bond plant equipment.
-
product
3U OpenVPX 2-Slot Backplane With 1 VPX Power And Ground Plus 1 VITA 62 Power Supply Slot
101VPX302P-2X13R
This 3U Open VPX backplane offers one VITA 46 Power and Ground slot and one VITA 62 power supply slot to support the development and deployment of systems requiring a VITA 62 power supply. The rear power studs can be used to connect to an adjacent backplane to feed it power.
-
product
3U VPX 3 Slot Power & Ground, 2 x VITA 67
1900002601-9001R
The only assigned pins on these backplanes are for 3.3V, 5V and 12V power, and both ground and utility planes are defined. The remaining pins are all user-defined. The rear connectors are all fully populated.
-
product
Common Point Ground Connector
Q007-T
The Prostat Q007B Qube™ replaces ordinary electrical grounding devices with a convenient, cost effective means to connect several ESD controls to a single grounded electrical outlet. Use the Q007B Qube™ to ground workstations, mats, wrist strap & testers, instruments, and other ESD control products to a pre-tested facility electrical ground. It consists of a robust multi receptacle frame encased in fire retardant ABS with a solid brass grounding pin.
-
product
3U VPX 1 Slot Power & Ground 25G Pass Through
101VPX301P-9X13
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
3U VPX 5 Slot Power & Ground 10G Pass Through
101VPX305P-9X21R
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
product
Ground Network Earth Resistance Tester
HTDW-5A / 736
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for the test of grounding resistance of large power grid in power departments, substations and other institutions.
-
product
Earth Ground Resistance Meter
1623-2
The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps.
-
product
3U OpenVPX 2-Slot Backplane With 1 VPX Power And Ground Plus 1 VITA 62 Power Supply Slot
101VPX302-xxxx
This 3U Open VPX backplane offers one VITA 46 Power and Ground slot and one VITA 62 power supply slot to support the development and deployment of systems requiring a VITA 62 power supply. The rear power studs can be used to connect to an adjacent backplane to feed it power.
-
product
Ground Testing
Weshine Electric Manufacturing Co., Ltd
1.Soil resistivity tester supports 2, 3 and 4wire grounding resistance measurement. 2. 4digit large LCD display with white screen backlight, suitable for use in dimly lit places. 3. IP65 protection grade, good waterproof, compact and portable, supports multiple functional tests.
-
product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
product
3U VPX 1 -Slot Power & Ground With VITA 67.1 Connector Installed J2
101V301P03-9002R
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.