Product
Static Grounding Protection for Process Plant & Equipment
Earth-Rite PLUS
-
Precision and reliability is what the Earth-Rite PLUS provides to HAZMAT professionals and engineers who are tasked with protecting personnel and plant assets from the ignition hazards of static electricity during tank car, LACT & skid unit and tote loading/unloading operations.
-
Product
Below Ground Insulator Tester
CE-IT
-
The CE-IT gives fast and accurate testing of below ground insulators and road crossing casings. This fully automatic unit tests the insulator without any adjustment by the operator needed.
-
Product
Ground Fault Finder
FST-JD200 DC
-
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
Product
5mA High Accuracy Ground Fault Detector
HA-GFD
-
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Product
Earth Ground Clamp Meter
T2000
-
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
Product
Grounding Series
-
Weshine Electric Manufacturing Co., Ltd
It is widely used in measuring ground resistance of electric power, telecommunication, meteorology, construction, lightning protection and industrial electrical equipment.
-
Product
Generator Neutral Grounding & Leads Cubicles
-
Generator Neutral Grounding Cubicles are designed to minimize fault damage incurred by generators, maintain sufficient fault detection and improve power system reliability. Generator Neutral Grounding and Lead Cubicles are manufactured as for IEEE or IEC standards.
-
Product
Ground Testing
-
Weshine Electric Manufacturing Co., Ltd
1.Soil resistivity tester supports 2, 3 and 4wire grounding resistance measurement. 2. 4digit large LCD display with white screen backlight, suitable for use in dimly lit places. 3. IP65 protection grade, good waterproof, compact and portable, supports multiple functional tests.
-
Product
Earth Ground Test Lead Kit
TL-796
-
*Earth Resistance Test Lead Kit*For use with IDEAL 61-796 3-Pole Ground Resistance Tester
-
Product
Ohm-Stat Ground/Circuit Tester to Test ESD Ground
-
Tests ground for all 110v electrical circuitsWill determine the status of all electrical groundsEasy to use LED lightsWarranteeProduct conforms to the ESD S.20.20 spec standardsIdentify electrical problemsUsed with the Ohm-Stat RT-1000 resistivity meter
-
Product
Guardian Ground Bond Tester
19572
-
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
Product
Long Spring Ground for ZD Differential Probe Qty 2
PACC-ZD003
-
Long spring ground for ZD differential probe Qty 2
-
Product
Resistance Grounded Systems (HRG/LRG)
-
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
Product
Ground-Fault Products for Solidly Grounded Systems
-
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
Product
12-bit, 4 Analog Current Outputs With Separate Grounds, Optically Isolated 500 V
APCI-3504-C
-
4 analog current output channels with 500V optical isolation, 12-bit resolution, each output has its own ground line.
-
Product
Earth Ground Tester
-
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
Product
Probe Tip Ground Lead with 0.8 mm Socket
PK007-024
-
Probe Tip Ground Lead with 0.8 mm Socket.
-
Product
Service Ground Test Set
900
-
TESCO’s Service Ground Test Set has been designed to check the condition of the ground connection on a secondary service. If for any reason the ground connection has a resistance, this can be immediately detected by the Test Set. The Service Ground Test Set consists of a voltmeter which can be shunted by a resistance of 60 ohms. The voltmeter is of the suppressed zero type with a double range, from 65 to 130 or from 130 to 260, and can be used for checking service voltage independently of the ground test.
-
Product
Easy Pole Clamp-On Ground Resistance Tester w/ Super Slim Jaw
FT6380
-
The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
-
Product
Aeronautical Ground Earth Station Emulator
GES
-
Square Peg Communications Inc.
Ground Earth Station (GES) emulator provides a simple and flexible means of testing the operation of Aeronautical Earth Stations (AESs) and end-to-end applications for the Inmarsat Classic Aero service, without the expense of airtime charges. It can be used to test basic AES functionality, including Aero I/H+ and Aero H voice calls, and data transfer applications such as ACARS.
-
Product
Shoes and Wrist Strap Tester
WST100
-
Tester designed for checking the conformity of operators wrist strap and/or shoes to the ESD protection standard. It is also designed to be permanent wall mounted in a production facility for daily testing of employee’s wrist straps and footwear.
-
Product
Electrical Ground Support Equipment:
EGSE
-
Keysight provides a variety of configurable test systems for satellites and satellite flight hardware; including Solar Array Simulators, Battery Simulation and Conditioning, RF signal simulation and analysis as well as fully custom solutions.
-
Product
Stator Ground Protection Relay
SEL-2664S
-
Schweitzer Engineering Laboratories, Inc.
Protect high-impedance grounded generators from ground faults at standstill, during startup, and while running with the multisine frequency injection and neutral overvoltage-based protection in the SEL-2664S.