Showing results: 1006 - 1020 of 1233 items found.
-
Botron Inc.
Botron's Digital/Analog Audit Kit insulation and continuity tester is designed for electrical testing. The wide range of test voltages makes the Audit Kit ideal for users involved with ESD testing. The kit gives greater functionality with simplified operation and an ergonomically designed case.
-
Power Diagnostix Systems GmbH
Partial discharge monitoring systems can be used for permanent surveillance of insulation systems on GIS, transformers, rotating machines, motors, cables, or other high voltage equipment. These instruments are designed for long term data recording, alarm handling, event recognition, and system integration.
-
TM800 -
T&M Tools Limited Co
TM800 Cable Fault Locator is a portable field instrument working on TDR and bridge methods, adopting advanced micro-electronics technology. It is designed to locate accurate fault points in such cables as telecommunication leadsheathed cable, plastic cable or user’s lead covered wire, while the faults include break, mix, earthing, defective insulation, or poor connecting. It is and ideal function-stable instrument for the field operator to improve work efficiency, in addition, it can also be used for circuitry project checking electric property testing of the cable.
-
PCT 1 -
Shanghai Powoo Industry Develop Group Limited
- completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the secondary lead wire is pin format, which can be directly welded on a PCB; - the primary lead wire could be pin, soft wire as well as tin-plated copper-core wire; - linear output current, high precision; - small volume, light weight, easy for installation; - encapsulated with epoxy resin to ensure strong insulation ability; - ABS anti-combustion plastic casing.
-
92-965-200-M -
Pickering Interfaces Ltd.
Suitable for use on the front of PXI modules this connector block provides a simple method of connecting to high density 200-Pin LFH connectors. The screw terminals use a rising cage screw clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximize copper cross sectional area and insulation properties. Users should make their own cable strain relief arrangements and ensure that appropriate electrical safety precautions are observed.
-
Hilkar
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
DE-5030 -
DER EE Electrical Instrument
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
Eltel Industries
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
HVTS-70/50 -
Kharkovenergopribor Ltd.
Portable system HVTS-70/50 is designed for carrying out high-voltage withstand testing of cable insulation and other solid dielectrics with DC (rectified) voltage up to 70 kV and AC voltage up to 50 kV RMS at industrial frequency (f = 50 Hz).
-
HVT-70/50 -
Kharkovenergopribor Ltd.
Portable system HVT-70/50 is designed for carrying out high-voltage withstand testing of cable insulation and other solid dielectrics with DC (rectified) voltage up to 70 kV and AC voltage up to 50 kV RMS at industrial frequency (f = 50 Hz).
-
CTT -
ndb Technologies Inc.
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
KV Hipot Power Test Equipment Co.,Ltd
High Voltage testing is usually performed to qualify the device to operate safely during rated electrical conditions, a way to check the effectiveness of its insulation. The objective sought during the high voltage testing will determine the type and amount of voltage applied and the acceptable current flow.
-
TD-1 -
AJIT Electronics Co.
By measuring the electrical properties such as capacitance and Tan-Delta regularly on periodical basis, it is possible to ensure the operational unexpected breakdown. Dissipation factor (Tan Delta) is one of the most powerful off-line nondestructive diagnostic tool to monitor the condition of solid insulation of various high voltage equipment.
-
PAT-815 -
Sonel S.A.
TECHNICAL SPECIFICATIONFILESPAT-815 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters.
-
Weshine Electric Manufacturing Co., Ltd
This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.