Discharge
-
Product
Lightning discharge counters
CDR-401
-
CDR-401 is the new counter which complies with the latest applicable Lightning Protection related Standards.
-
Product
Portable GIS Partial Discharge Detector
JHPD-10
-
Xiamen Jiahua Electrical Technology Co.,Ltd
JHPD-10 quickly and accurately detects various kinds of partial discharge signals that occur with insulation defects in GIS. Attached on the surface of GIS the detector collects the inside discharge signal of impure gas, suspension potential and solid insulation material. The diagnostic software analyzes the fault character and locates the fault to avoid electricity accident. The device is for daily patrol inspection with high efficiency and easy operation features. Designed with two UHF signal channels, one detects the partial discharge signal; another excludes the disturbance signal like corona discharge in the air and mobile phone communication.
-
Product
Capacitive Discharge Testers
-
For IEC Testing of residual voltage after plug disconnect. The CDT-240 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results. Scope output for viewing decay waveform. Presets for EN 61010, EN 60065, EN 60950, EN 60601-1 and EN60335. Recommendations for Pluggable Type B equipment. NIST calibration supplied; A2LA calibration available. 16A option for testing large equipment.
-
Product
Partial Discharge Testing Equipment
3i
-
The portable multipurpose 3i device (Intellectual Insulation Indicator) is for eff ective high-voltage equipment insulation monitoring on-line. The 3i device measures and analyses partial discharges (PD). For eff ective PD measurement and noise rejection, there are two types of sensors used in the device: the acoustic sensor and the TEV sensor. Both the sensors are built into the device case, and so do not need any connection cables. The device is supplied in a strong metal case; at the faceplate there are the colored screen and two buttons: power button and function button.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
Discharge Units
-
ENTES Discharge Units are used in capacitor banks and provide quick discharge over short periods of time.
-
Product
Electrostatic Discharge Simulator
ESD61000-2
-
ESD simulator (Electrostatic Discharge Generator or Electrostatic Gun) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performance. ESD61000-2/ESD61000-2A has LCD display in both English and Chinese, they equipped with an infrared remote control which can allow you do the test in some special place.
-
Product
Partial Discharge Tester
GTPD-4C
-
GTPD-4C partial discharge comprehensive tester is the new generation of digital PD measurement and analysis instrument. The instrument has a strong ability of comprehensive analysis of partial discharge and detection of partial discharge in small signal and strong interference environment. With different accessories, it can measure and locate the partial discharge in any high voltage electrical equipment. It can realize testing the transformer partial discharge by applying the voltage on the three phases simultaneously.
-
Product
Partial Discharge Measurement System
DAC-6021
-
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
Product
BOD (Biochemical Oxygen Demand)
-
The role of Biochemical Oxygen Demand (BOD) is to measure the amount of oxygen needed to remove organic waste from the water of bacteria.Important to know, the larger the Biochemical Oxygen Demand, the more rapidly oxygen is depleted in the stream. This means there will be less oxygen in the water.biological oxygen demand is essential By providing information to assess the effect discharged wastewater will have on the receiving environment.The BOD value is commonly expressed in milligrams of oxygen consumed per liter of sample during 5 days of incubation at 20°C.The goal is maintaining the aquatic life and aesthetic quality of streams and lakes.
-
Product
Riverboat SP
-
Teledyne Marine RD Instruments
The Riverboat SP is the top choice for deployment of the Teledyne RDI StreamPro acoustic Doppler current profiler. Upgrade from the standard StreamPro float to the more stable, rugged and fully corrosion-resistant tethered boat. The Riverboat SP makes safe, easy measurements of discharge in relatively slow and fast flowing waters. Made of unbreakable polyethylene, the Riverboat SP is strong and can handle tough deployment conditions. The standard boat configuration fits a TRDI StreamPro ADCP, and the latest instrument clamp is suitable for the StreamPro with or without an internal compass upgrade.
-
Product
Condenser for General Applications
PECA2
-
Lifasa - International Capacitors, SA
These capacitors are designed for use in circuits where they are subjected to non-sinusoidal voltages and pulsed currents, such as switching and damping circuits. They can also be used as discharge and filtering capacitors, as well as for any DC application. This capacitor is especially suitable for applications where a high life expectancy and a high RMS current are required.
-
Product
High Voltage Op Amplifiers ≥12V
-
High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.
-
Product
Battery Charger/Discharger
BCD-3933T
-
Kongter Test & Measurement Co., Limited
Specially designed for single cell of 6V and 12V ONLY with max current of 50A. Three functions in one: charger, discharger and activator, which will facilitate your maintenance for batteries.
-
Product
HDDH-3932 Single Cell Battery Activator
-
HD Power Test Equipment Co.ltd
HDDH-3932 Cell Activator is used to discharge and charge and activate for disable single cell battery, which is simple, safe and accurate test device.The instrument is with perfect protection function, sound and light alarm and clear interface tips.
-
Product
Charge Meter
NK-1001A/NK-1002A
-
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
Product
Ultrasonic Leak Detector
ULD-420
-
When equipment begins to fail due to an air or gas leak or vibration, or electrical discharge, the leakage point emits an ultrasonic sound wave that is above the natural range of human hearing. The ULD-420 Ultrasonic Leak Detector converts this ultrasonic sound into a signal that can be used to pinpoint the exact location of the equipment failure. When working in unpressurized systems or the pressure is not sufficient enough to detect or verify a leak with the Receiver alone use the Transmitter.
-
Product
Tan Delta Measurement
TD Series
-
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
Product
Lithium Battery Discharge-Charge Unit
FGCD
-
Fuzhou Fuguang Electronics Co., Ltd.
FGCD series tester adopts advanced charging and discharging technology with a variety of built-in test and maintenance modes, which are suitable for the discharge, charging and discharge-charge cycle tests of various lithium battery packs on the market.
-
Product
Water Quality Monitoring System
WQMS
-
Water Quality Monitoring System (WQMS) is a facility to measure pollutants such as Chemical Oxygen Demand (COD), Total Phosphates (TP), Total Nitrogen (TN) etc. The required parameters are customized according to the type of factory and discharge regulations.
-
Product
Component Testers
-
Unlike other handheld instruments such as LCR meters that make measurements using an AC signal with a specific test frequency, the 830C measures capacitance by applying a constant current that briefly charges, then discharges the connected capacitor.
-
Product
Scienlab Battery Test System - Cell Level
SL1007A
Test System
The SL1007A Scienlab Battery Test System – Cell Level enables you to accurately and productively test battery cells for automotive and industrial applications. The bidirectional power supply charges and discharges your cells under test with very high efficiency.
-
Product
IMPULSE SURGE WINDING TESTER
VE2882A-5U
-
Impulse Tester can detect turn & layer short ,the differences in the number of turns and the material of the core. If high impulse voltage is applied, the poor insulation will appear as a corona or layer discharge.
-
Product
Handheld ESD Simulator
-
Battery operated handheld ElectroStatic Discharge (ESD) generator up to 30kV.Discharge networks according to IEC 61000-4-2, ISO 10605, MIL-STD-461 CS118, DO-160 section 25 and many more standards.
-
Product
Discharging Bars
-
VARIO discharge products consist of a separate AC power supply for connecting one or more Eltex discharging components. In SINGLE discharging, the voltage generation (power supply ) is integrated in the bar.
-
Product
IT Battery Test System
-
Shenzhen Sinexcel RE Equipment CO., Ltd
IT battery test system support for multiple charging mode (such as CC, CV, CP, pulse, etc.) and discharge mode, to ensure that the battery performance and safety in the practical application. IT battery test system is designed to be modular, easy to maintain, and with anti-reverse connection, data loss and other protection functions
-
Product
RS232 / RS485 / RS422 / Ethernet Surge Protectors
-
Our passive, rugged, industrial-grade RS232 / RS485 / RS422 / Ethernet surge protectors are designed for direct industrial DIN-rail mounting and they come with two (2) or three (3) stages of surge protection — Gas Discharge Tube (GDT), protection resistors, and Transient Voltage Suppressor (TVS) - for maximum protection. From 2-wire RS485, 4-wire RS422 / RS485, to 10 / 100 / 1000M Ethernet, CommFront's surge protectors safeguard your data lines and provide you with a peace of mind.
-
Product
Cable Partial Discharge (PD) Spot Testing And Locating
PrecisePD
-
PrecisePD is an on-line PD Spot Testing and PD location system for Cables and Switchgear with advanced signal processing, used for the detection of PD in high noise environments.
-
Product
DC System Tester
VAFDT220
-
Substation DC System Tester is applied to test battery charger(voltage stabilizing accuracy, current stabilizing accuracy, ripple factor etc.), battery bank discharge, and monitor the charging process of battery bank.
-
Product
Dual Surge Current Generator
MIG0624T-K12
-
Designed for testing telecom surge protection devices according to ITU-T K12. The generator has two indepedent impulse outputs which allow testing of two and three terminal protection devices such as gas discharge tubes (GDT). The generator can be configured for two terminal devices or with the outputs in parallel to increase the current impulse for two terminal devices.