Wind Tunnels
deliver specific air-stream to characterize air-flow's affect.
See Also: Wind, Tunnel, Anemometers, Wind Turbine, Wind Speed
-
Product
TRANSFORMER WINDING RESISTANCE METER
-
International Biological Laboratories
This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Product
Dual Mode Wind Turbine Performance Lidar
ZephIR DM
-
ZephIR DM is a Dual Mode variation of the successful 300 system. ZephIR DM measures wind characteristics in front of or behind a turbine from just 10 metres (33 feet) out to 300 metres (984 feet) situated inside the spinner or on top of the nacelle, during the operation of wind farms onshore and offshore (this is limited to 200m (656 feet) when in ground based vertical mode).
-
Product
Wind Direction Sensor
ENVIROMUX-EWDS
-
Balanced wind direction vane with a near-zero friction bearing and a high accuracy magnetic angle sensor to provide precision wind direction. Sensor range: full 360 degrees , zero deadband. Accuracy: ±1.8 degrees. Resolution: 12 bit or 0.025 degrees. Directional Vane approximately 8 inches (203 millimeters). 3 wire flying leads, 25-feet (7.6-meter). Supply voltage: 4.5 to 5.5 VDC. Current: 15 mA typical. Output: 5 to 95% of input voltage (0.25 to 4.75VDC). Requires the ENVIROMUX-S5VDC-5V to operate with ENVIROMUX-2D/5D/16D. Maximum cable length: 1000 ft (305m)
-
Product
Transformer Winding Resistance Testers / TRT ? 2
TRT-2
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 0.02A to 2A DC, Digital display of resistance and test current.
-
Product
Solid-State Wind & Meteorological Measurement System
AGIMET
-
Aeronautical & General Instruments Ltd.
AGIMET uses the latest proven solid-state meteorological sensor technology specially designed for the marine environment to provide accurate measurement of wind speed and direction, temperature, pressure, humidity and other local environmental parameters.
-
Product
Winding Resistance Meter 50Amps, 3 Channels Rack
WR50-13R
-
Raytech Digital Winding Resistance meter WR50-13R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Wind Power Solution
NXA GAMESA
-
The NXA GAMESA is custom-made with firmware and fixtures designed specifically for Gamesa turbines: G80x, G90x, G114, G126, G132, G145. These precisely designed fixtures make generator-to-gearbox alignment easy inside any nacelle – safeguarding reliability and optimizing the energy efficiency of the wind turbine.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Winding Resistance Tester
JYR20S/10S
-
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Tunnel Demagnetizing Unit
DM-T
-
Tunnel units are particularly suited to demagnetising parts with large surface areas and thin walls, for example, tubes, rods, etc.
-
Product
Wind Power Solution
NXA SIEMENS
-
The NXA SIEMENS is custom-made with firmware and fixtures designed specifically for Siemens 2.3, 2.4, 2.6, 3.6, and 4.0. These precisely designed fixtures make generator-to-gearbox alignment easy inside any nacelle – safeguarding reliability and optimizing the energy efficiency of the wind turbine.
-
Product
Bobbin Winding Coil Turns Tester
SS108A series
-
Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.
-
Product
Winding Resistance Test
20A DC booster
-
The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
-
Product
Winding Resistance Meter
TRM 50+
-
SCOPE introduces 50 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 50 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Winding Resistance Meter 50Amps, 2 Channels
WR50-12
-
Raytech Digital Winding Resistance meter WR50-12 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
High-Current 4-Wire Winding Resistance Meter
TWO-1100S
-
Shenzhen Feso Automation Technology Co., Ltd.
High-current 4-wire winding resistance meter with DC test current up to 100 A — measures 30 µΩ–4 Ω with ±0.2 % reading accuracy for transformer and rotating-machine windings.
-
Product
Scanning Tunneling Microscope for Ultra High Vacuum
STM
-
A.P.E. Research instrument is a versatile Scanning Tunneling Microscope, STM, capable of scanning samples of almost any size. It can operate in UHV and in air. The systems have been designed to evaporate (e.g. metals, organic molecules) in UHV directly onthe sample mounted on the STM head.
-
Product
Remote Sensing Wind Measurement Device
WINDCUBE
-
WINDCUBE is a remote sensing wind measurement device that uses pulsed Doppler Lidar technology to provide high quality data on par with an IEC calibrated met mast. Introduced to the market by LEOSPHERE, WINDCUBE has quickly become recognized as the market standard for superior performance for both wind resource assessment and wind farm performance monitoring. Lenders have readily adopted data provided by WINDCUBE and consider this device to be “best-in-class.” WINDCUBE is categorized as being in Stage 3 of DNV GL’s rigorous standards related to remote sensor acceptance for formal energy assessment purposes.
-
Product
Wind Speed Sensor/Anemometer
ENVIROMUX-WSS
-
Rugged anemometer. 3-cup rotor pressed on a stainless steel shaft. Reed switch and magnet providing one pulse per rotation. Rotor diameter: 5 inches. Speed range: ~ 3 mph to 125+ mph (~5 kph to over 200 kph). Rugged Delrin body with bronze and Rulon bushings. Flat aluminum mounting bracket with 2 holes. esigned to be mounted on top of a pole or bracket. 100 feet of exterior grade wire. Maximum cable length: 1000 ft (305m).
-
Product
High-precision Surface Inspection for Wind Turbine Blades
waveCHECK™
-
8tree's waveCHECK is a handheld-portable 3D-inspection tool for inspecting wind turbine blades in manufacturing and operation. Its efficient detection of surface defects and instant visual feedback revolutionize surface inspection.It can detect wrinkles, steps, gaps, rain erosion and any other surface damage.
-
Product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
-
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.
-
Product
Winding Resistance Meter 50Amps, 3 Channels
WR50-13
-
Raytech Digital Winding Resistance meter WR50-13 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
WINDING COIL TURNS TESTER
VE201R
-
Winding Turns Tester for Counting Measuring Number of Turns for Air Core Coils, Bobbin Coils or Solenoid Coils. Can Measure : Turns along with Winding Polarity and DC Resistance.Turns Measurement : 1 Turns to 80,000 Turns
-
Product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
-
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
Product
Tap Changer Analyzers & Winding Ohmmeters
-
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
Product
Transformer Winding Resistance Testers / TRT ? 27
TRT-27 series
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 2.5A to 20A, Digital display of resistance and test current.