Filter Results:
Products
Manufacturers
Applications
Breaker
-
product
Primary Injection Test Systems
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
product
Handheld Micro-Ohmmeters
RMO-H Series
The RMO-H is battery operated and handheld micro-ohmmeter. It is designed for a variety of applications for contact resistance measurement of non-inductive test objects. Typical applications are accurate testing of:medium and high-voltage circuit breakers,disconnecting switches,high-current bus bar joints,cable splices,and different high-current links.Even more, it accurately measures in high-induction filed environments and substations, as well as in factory testing.RMO-H Series contains six models in total, divided in 2 sub-series depending on the test leads length requirement and the battery type:RMO-H1, RMO-H2 and RMO-H3 models are intended for use with short cables (e.g. 1,3 m / 3 m / 5 m). The 1-cell Li-Po battery with 8200 mAh capacity provides output voltage up to 4,1 V DC.RMO-H21, RMO-H22 and RMO-H23 models are ideal for applications where test leads with lengths > 5 m are required. The high output voltage (up to 8,3 V DC) is provided by 2-cells 4100 mAh Li-Po battery.The test current is regulated and can be selected in a range of 1 A to maximum 300 A, depending on the maximum test current rating:RMO-H1, RMO-H21 models – up to 100 A DCRMO-H2, RMO-H22 models – up to 220 A DCRMO-H3, RMO-H23 models – up to 300 A DC.Unlike many other handheld micro-ohmmeters available on the market, our instruments have regulated and user-selectable test currents. Therefore, RMO-H instruments generate an automatically regulated test ramp with stable and ripple-free current during measurement. These revolutionary characteristics in a handheld micro-ohmmeters technology are possible by using sophisticated Li-Po batteries. Consequently, modern battery technology enables you to do multiple measurements, and a full day of testing without recharging the battery.With all RMO-H models, it is possible to make tests on Both Sides Grounded testing objects, in an increased safety environment. Finally, these features in combination with a user-friendly interface (1-click to measure) significantly speed-up testing procedure and make it safer.These instruments store up to 1000 measurements on the internal micro SD card.Our free DV Win software communicates with the RMO-H micro-ohmmeters via a wireless Bluetooth interface. Furthermore, it allows you to download test results, analysis and generate fully configurable test reports.
-
product
Serial AC Power Sequencer
90-200-001
Each power outlet can be programmed to switched on in sequence with a specific timing delay. The delay can be staggered to ensure that order dependent systems - like PXI - can be switched on and off in an orderly way with just one operation. A staggered start up also limits the inrush current associated with the powering up of equipment, including earth current inrush, placing less stress on cabling and leakage breakers. Power on or off instructions can be initiated from either the front panel switch or via the serial interface.
-
product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
product
Primary Current Injection Testers
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
product
VARIABLE TRANSFORMER DC POWER
208163V
Motorized Variable Transformer Controlled Power Supply, P/N 208163VInput power: 208 VAC, 6 Amps, 3 PH, 60 HzOutput: 0 to 120 VDC, 16 Amps max.Ripple: 5%Manual control with variable transformerCircuit breaker / ON OFF on the 208 VAC, 3 PH input lineProtection fuse provided on the outputPOWER ON lightIndoor enclosure: 24H x 20W x 9DVoltmeter and ammeter are installed to monitor the output.All input/output connections are available inside the enclosureSystem includes main unit and remote assembly.
-
product
MICRO OHM-METER
UONT100A
International Biological Laboratories
This Test Set is capable to measure low resistance like switch contacts, breaker contacts, busbar splices, joints, fuses, low inductive windings etc. by circulating high value of D.C. through the contact/junction and measuring D.C voltage drop (4 terminal method) which, sent to instrument amplifiers , thereby being displayed on resistance meter.
-
product
Lock Out Kit
LOKKIT1
The Martindale universal lock out kit is compatible with most circuit breakers. It is supplied with a padlock that has its own unique key, and a safety hasp that enables multiple users to lock off with space for up to 6 padlocks.
The full 16 piece kit includes: 1 x Padlock with unique key, 1 x Steel safety hasp with space for up to 6 padlocks, 1 x Green mini MCB lock, 1 x Yellow mini MCB lock, 1 x Blue medium MCB lock, 1 x Large red MCB lock, 1 x Small red MCB lock, 1 x Red fuse lockout breaker, 1 x Yellow fuse lockout breaker, 5 x Danger tags which can be overwritten, 1 x Black marker for writing on Danger tags, 1 x TC55 soft carry case
-
product
First Trip Testing of Circuit Breakers
Significance of Circuit Breaker "First Trip Time"A circuit breaker may not be called upon to operate and clear a fault for years, but when a fault occurs, it is expected to operate within it's published time-current characteristics. Unfortunately, frequently this does not happen... environmental contaminants, hardened grease, vibration and other factors can adversely affect the operating time of the circuit breaker.
-
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT MXP+
SCOT MXP+ measures, displays and prints CLOSE, OPEN and CLOSE-OPEN time of 2 Main + 2 PIR contacts per pole, 3 poles simultaneously, ensuring measurement of 6 Main + 6 PIR contacts simultaneously. Ideally suitable for CBs having PIR contacts & multiple breaks per pole
-
product
Circuit Breakers
As the premier supplier of power system components, Interpower has what you need to complete your projects, including circuit breakers. Interpower has no minimum order requirements, plus same day shipping is available on in-stock Interpower products.
-
product
Surge Arrester Testing
Weshine Electric Manufacturing Co., Ltd
This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.
-
product
Switchgear Testing Solutions
IES Systems is a world leader in the design and manufacturing of power switchgear test systems.*GFCI/AFCI Circuit Breaker Test Solutions*Medium Voltage Breaker Test Solutions*Residential Circuit Breaker Test Solutions*Molded Case Circuit Breaker Test Solutions*AIR Circuit Breaker Test Solutions*Vacuum Bottle Test Solutions
-
product
ELM Electronic Load Module
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
product
24 V DC Power Supplies
*Space-saving design*High power reserves*Low heating of the control cabinet*Low inrush current*Safe switch-off by circuit breakers in case of short circuit
-
product
Circuit Breaker Finder
6504
Peaceful Thriving Enterprise Co Ltd
Circuit Breaker Finder is a multi-function circuit tracer/ identifier. Circuit Breaker Finder identifies circuit breakers without interrupting service.This device is formed by 1x Transmitter and 1x Receiver. There are 3 functions: (1) Socket Tester (Wire Mapping)(2) Circuit Tracing / Identifying(3) Non-Contact Voltage Detecting
-
product
Power Supplies
AC and DC power supplies are used for providing the power required for energising the trip and close coils of the breaker and for running the spring charging motor. The appropriate AC or DC configuration of the power supplies can be selected, depending on the DUT specifications of the manufacturer. Dual-mode AC/DC power supplies capable of providing AC and DC outputs from the same power supply are also available, if required by the user.
-
product
Measuring Display Unit Breakers
Mitsubishi Electric Automation, Inc
Measuring display units (MDU) are integrated with molded-case circuit breakers and earth leakage circuit breakers for measuring, displaying, and transmitting information on cable ways. This display unit closely monitors energy consumption by measuring current, voltage, power, electric energy, harmonic current, leakage current and power factor.
-
product
Coil Analyzers & Power Supplies
Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.
-
product
Primary Injection Test System
HAOMAI Electric Test Equipment Co., Ltd.
Primary injection testing is suitable for testing over-current trip relays attached to a circuit breaker.
-
product
Circuit Breaker Endurance Test System
Endurance testing involves operating – closing and opening – the circuit breaker repeatedly for a set number of cycles. This test is necessary to stabilize the circuit breaker mechanism and to identify “Early Infant Mortality” failures in the switchgear assembly.
-
product
Panel Meter Calibrator
1040C/CU
Calibrate panel meters, transducers, circuit breakers and relay units with Model 1040C, a portable, field-ready unit featuring eight key calibration functions.
-
product
Trip Indicator Relays
TIR
The TIR relays are designed for event recording circuit applications, where high speed event monitoring is required. The TIR relay contacts are used to record breaker functions, relay, communication and control system operations. The TIR contacts are also used to activate alarm and/or annunciator contacts.
-
product
Contact Resistance Tester
JYL-200B/100B
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
product
AC Relays
The E-MAX ATR and ACV Relays are the AC equivalents of the industry standard E-MAX TIR Trip Indication Relays and AVR Auxiliary Voltage Relays. While the TIR and AVR Relays are designed for use in DC trip circuits, the ATR and ACV are designed for use in AC trip circuits. The relay outputs may be used to record breaker, relay, communication and control system operations, and to activate alarm and/or annunciator contacts. Relays do not require standby power to operate; they are powered by their inputs.
-
product
Circuit Breaker Testing
The DRM-1A™ is a lightweight and portable micro-ohmmeter designed to measure very low resistances from 1 μΩ to 200 Ω. It is the most accurate in its category.
-
product
Circuit Breaker Test Systems
Crest has over a decade of experience of designing and manufacturing test systems for testing all the different kinds of switchgear and controlgear.
-
product
Circuit Breaker Identifiers
188 FFF
Standard Electric Works Co., Ltd
● The 188FFF doesn't have the function of the sensitivity adjustment. If the customers need the sensitivity adjustment function, plase refer to other models.● The 188FFF is a Fuse and Fault Finder which comprises of two parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered by the mains and requires no batteries.● The 10kHz signal current generated by the Transmitter is then searched(sniffed) by the Receiver to detect the Fuse, Circuit Breaker or the faulty circuit.● The Receiver is a tuned circuit which has it's center frequency tuned to about 10kHz. The sensor is located in the tip of the Receiver.● The amplitude of the received signal is shown on a bar-graph type Leds.● The more Leds ON, the stronger the signal.
-
product
Breaker Testing Software
BTS11
To test circuit breakers in general, is to operate the breaker and check the contact timing. However in factory testing and during field service/maintenance some other tests are necessary. For field testing these other tests can also be very useful in diagnostics purpose.





























