Breaker
-
product
Coil Analyzers
Sat40a II Series
The Coil Analyzer SAT40A II series is a powerful tool for testing circuit breakers where a substation battery is not available. It is unique device in the market due to its dual purpose: - It can be used as a stable power supply for coils and spring-charging motors (both DC and AC power supply voltage) during commissioning and maintenance testing. - It is powerful analysis tool for assessing conditions of circuit breaker auxiliary circuit and coils. The Coil Analyzer SAT40A II series has separate DC and AC coil outputs for power supply of opening and closing coils. The output voltage is selectable in the ranges from 10 V to 300 V DC or from 10 V to 250 V AC. The Coils outputs can withstand up to 15 A current. The DC and AC motor outputs can generate from 10 V to 300 V DC and 250 V AC voltage. The motor outputs can withstand starting (inrush) currents up to 40 A. These outputs can also be used as continuous power supply outputs.
-
product
Circuit Breaker Test Equipment
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
product
SF6 Optical Gas Imaging Camera
FLIR GF306
The FLIR GF306 optical gas imaging camera visualizes sulfur hexafluoride (SF6) and other gas emissions without the need to shut down operations. SF6 is used in the electric power industry as an insulator and quenching medium for gas-insulated substations and circuit breakers. The portable, non-contact GF306 allows you to quickly scan substations for leaks while maintaining a safe distance from high-voltage equipment. By catching leaks early, the GF306 reduces lost revenue to breakdowns and repairs.
-
product
Short Circuit Loop Impedance Meter
AMZC-305
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
product
HV High Performance Circuit Breaker Analyzer
CBV-19
We conceived the CBV-19 to provide the best range of testing for electrical facilities such as circuit breakers (using gaz, oil, air, vacuum…) or synchronous condensers all the way up to 800kV and more. It combines Timing, Motion, Dynamic Resistance Measurements, and Vibration, all in a single test.
-
product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
product
Environmental Chamber
REXMED REC-280
MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
Ground-Fault Location Products for Ungrounded Systems
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
product
Electrical Measurement Equipment
Portable equipment designed for maintenance and commissioning of substations and power plants. Low resistance micro ohmmeters, digital timers, windings resistance, contact resistance, circuit breaker timing and motion, phase angle and frequency measurements.
-
product
Environmental Chamber
REXMED REC-200
MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
product
Circuit Breaker Test System
TDR900
It operates and records a circuit breaker’s contact timing, motion, velocity, main contact engagement & synchronization, trip and close coil initiation and currents.
-
product
Low Resistance Ohm Meters
DMO-100D
For fast and accurate measurements of low resistanceon Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds. • 100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A
-
product
Protective Bonding Testers
RMO-E Series
The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E
-
product
AC Electronic Load
AC&DC Electronic Loads are design for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors.
-
product
Adjustable Test Stab Set
The ETI adjustable test stab set may be used with your high-current circuit breaker testers to maximize efficiency and convenience for testing multiple breakers. Our stab system allows your technicians to test breakers in-place and avoid jacking breakers up or down for testing. By combining mobility and flexibility into one simple system, this stab set is a proven improvement over conventional designs. The components in the adjustable stab set are made of 120 pounds of 110 copper.
-
product
AC and DC 20-Amp Power Supply
ACDC-20
The ETI Model ACDC-20 is a rugged and portable 20-amp AC and DC power supply. Its applications include resetting circuit breaker charging motors and other general purposes. It will provide DC voltage in three nominal ranges from 0-120V, 240V, and 480V at 1.92 kVA, as well as AC voltage in three nominal ranges from 0-140V, 280V, and 560V at 2.8 kVA. The ACDC-20 is housed in a rugged plastic enclosure approximately 21.5” x 18.5” x 11.5” and weighs approximately 115 lbs.
-
product
Corona Discharge Checker
MK-720
MK-720 enables finding of insulation deterioration on insulators, disconnectors, and circuit breakers, at hot-line condition!
-
product
Circuit Breaker Monitoring
Circuit Breaker monitoring for all parameters required to accurately monitor the overall health and performance of circuit breakers
-
product
SF6 Leakage Detector
GDWG-IV
GDWG-IV SF6 Gas Leak Detector is infrared type leak detector. It is color LCD display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It's a good device suitable for power supply department, installation and overhaul unit, power test institute.
-
product
Circuit Mapper System
CMT24S/CMT42S
The Circuit Mapper is the first device of its kind that maps branch circuits of wiring systems concurrently with a single transmitter and receiver. Traditional methods of identifying circuit breakers and wiring are inefficient and expensive, often requiring two people to perform. With sensitive electronic equipment, simply turning breakers off and on is no longer a viable option.
-
product
HV Switch Operating Power
HTDY-H / 393
Wuhan Huatian Electric Power Automation Co., Ltd.
Dedicated power supply designed for inspection and maintenance of high voltage circuit breakers and their operating mechanisms.
-
product
3 Wire (Analogue) Earth Resistance Tester
2705 ER
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
product
Primary Current Injection Test Sets
Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.
-
product
Resistance Measurement
PROMET
High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.
-
product
Powerful AC/DC Power Supply For Testing Circuit Breakers
POB35AD
POB35AD is a power supply unit employing the latest power electronics technology. POB35AD generates ripple free DC-voltage and it is developed for regular maintenance tests of power circuit breakers. It eliminates use of stationary batteries during testing. Output voltage is selectable from 10 to 250V AC/300VDC. The test set is a powerful and versatile unit with possibility to generate up to 30A.
-
product
Contact Resistance Meter
CRM 200B+
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
product
Socket Outlet Tester
Using the new Testavit Schuki 1 LCD and 3 LCD, specialists easily check to see if sockets, cable drums or connecting cables are correctly connected in 230 V installations. Due to three LEDs, the connection status can be quickly and clearly determined. In addition, through the finger contact, it can be tested to see whether an impermissible, high contact voltage is applied at the protective earth connection. In addition, using the Testavit Schuki 1 LCD, a 30 mA FI circuit breaker (RCD) can be triggered via a pushbutton.
-
product
Current Differential and Overcurrent Relay
SEL-387
Schweitzer Engineering Laboratories, Inc.
Protect and control any two-, three-, or four-winding power transformer with the SEL-387, which provides thermal and through-fault monitoring, and with SELogic Control Equations, can detect breaker failure.
-
product
RCD Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.