Standard Agreement
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) Battery Probe
BIP-2
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 365Overall Length (mm): 9.27
-
Product
Low Voltage EMC Standards Tester
LVTGO-VBS
-
LVTGO-VBS is a range of low voltage battery simulation units for robustness and EMC standards testing. It helps engineers to meet standards stipulated by a range of manufacturers, such as JLR, Ford, VW, BMW and Mercedes-Benz.
-
Product
Standard Amplifiers
-
Teledyne RF & Microwave, a Business Unit of Teledyne Microwave Solutions (TMS), supplies catalog and custom RF and microwave amplifier designs for aerospace, defense, and industrial applications. These standard amplifiers, originally designed by Teledyne Cougar, provide both excellent stability and cascadability.
-
Product
Standard 1.00 (28.30) - 5.40 (153.00) Battery Probe
BIP-10
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
Product
Standard & High Speed Amplifiers
-
Advanced Energy's Trek high voltage power amplifiers employ unique and proprietary circuitry. Benefit from closed-loop amplifier systems that feature exceptional DC stability and excellent wideband performance characteristics. And thanks to all-solid-state designs, our amplifiers are protected from output short circuits and overvoltages.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4S
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF400
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of powerfactor in low voltage instalations
-
Product
Standard Bare Fiber Spools
-
*Custom lengths to 30km of optical fiber*Designed to fit spools in the most efficient manner*Portable for easy handling and protection*Organizes fiber while ensuring performance
-
Product
Standard Digital Multimeter - Auto Ranging
MM39
-
The MM39 is an auto-ranging multimeter with a large rotary switch for easy selection of the required test, even when wearing gloves. There are two test buttons, one to lock the range and the other to hold the results which are displayed on a 3½ digit LCD screen.
The main test functions are AC voltage and DC voltage and current and resistance. The MM39 measures both AC and DC voltage between 0.1mV to 600V and AC and DC current between 10mA to 10A. There is a diode test and an audible continuity test which sounds at less than 25Ω.
-
Product
Nanolattice Standards for Analytical Instruments
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
Product
The Gold Standard for Breast Screening & Biopsy Training
Mammography QA Solutions
-
When the USA mandated Mammography QA requirements via the Mammography Quality Standards Act (MQSA), medical physicists, the ACR and the FDA worked with Gammex to complete the phantom design known today as the 156 Phantom.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HF-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2TB-6
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Rubidium Standard with Optional DDS Signal Generator
1450B
-
The 1450B outputs can be configured as sine waves or square waves and can provide frequencies of 10MHz, 1MHz, 100kHz, 1pps or optional signal generator outputs. The signal generator outputs use direct digital synthesizer (DDS) technology and are confirurable from 100Hz to 171MHz. The 1450B also includes a 1pps input that can be used to discipline and automatically calibrate the 1450B. The 1pps input signal is typically obtained from an external device like a GPS frequency receiver/antenna. The Novatech GPS1 Smart Antenna with 1pps output is available as an accessory to provide a complete turnkey solution.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Standard Test Systems
WaveCore™ Products
Test System
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.
-
Product
Standard 1.27 (36.00) - 2.94 (83.35) Battery Probe
CCA-003
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 670Overall Length (mm): 17.02
-
Product
I/Q Signal Generation for Digital Radio Standards
WinIQSIM2
-
R&S®WinIQSIM2™ was especially developed to easily generate digitally modulated signals on a PC. The graphical user interface allows intuitive operation by offering a convenient way to create standard-conforming waveforms for many configurable digital standards and to generate multicarrier signals and multisegment waveforms. With these capabilities, R&S®WinIQSIM2™ covers a wide range of applications.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2250-9
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
Product
Standardize Production Test Software For PCBAs And Electronic Devices
test
The vast majority of test project man-hours are spent on software development, so the choices that teams make in software tools and architecture have significant impact on deployment schedules. Standardizing software across a team or organization increases both efficiency and proficiency, lowering the risk of missed deadlines and improving test quality and reliability. Test software must:
-
Product
Standard Products
-
DLM’s standard product range is designed by experienced in-house design engineers and manufactured at our workshop in the UK by qualified technicians.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-FK180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
Standard - 6.00 (170.00) - 14.00 (397.00) Feed Through Probe
P2447-1W
-
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 225Test Center (mm): 5.72Full Travel (mil): 300Full Travel (mm): 7.62Recommended Travel (mil): 200Recommended Travel (mm): 5.08Overall Length (mil): 1,145Overall Length (mm): 29.08
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5E
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07