Standard Agreement
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-2W1S
-
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Super MUTT Deluxe Standard Edition
#9008-SE
-
Innovative Products of America
The Super MUTT places a load on the trailer's electrical circuits to identify wiring problems while providing remote control operation over both air brakes and lights. Built to facilitate a one-man testing operation, the Super MUTT reduces guesswork and inspection time to prevent failures that lead to expensive road calls and citations. The remote control allows for repetitive air brake actuation at each axle to reveal developing problems often missed by normal testing procedures.
-
Product
FlexVNX+ Test And Development Platform Aligned To SOSA And VITA 90 Standards
39S08VPX98Y2VAN
-
Elma’s all-new FlexVNX+ Test and Development chassis is the next generation portable test platform designed to accelerate development and test of VNX+ plug-in cards (PICs) aligned to The Open Group® SOSA™ Technical Standard and VITA 90.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Xytronic Three-Phase Site Analyzing Standard
RADIAN RX-3X-A
-
The RX-3X-A Xytronic Three-Phase Site Analyzing Standard brings precision measurements, normally associated with laboratories, to the meter site at a surprisingly affordable price. How is this possible? Radian has always designed state of the art precision measurement equipment with extreme high and low operating temperatures in mind – all site analyzers are tested at -20C to +70C. Couple precision measurement with ruggedness, throw PCSuite software automation into the mix, you have the premier RX Site Analyzing solution to meet the most demanding site measurement challenges
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1C-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1F-4.5
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Viscosity Standards
-
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
Product
Standard Weather Radar Test Panel
TA-3
-
Universal weather radar test panel with integral gyro simulator and monitor jacks. Discrete test jacks for common signals, altitude select switches and a dedicated connector for the RDS series radars. Click on picture for larger view.