Resistance
that which keeps current from flowing freely.
See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire
-
product
Electrical Tomography
POLARES32
By exploiting an innovative technology based on the use of Alternating Current (AC), the POLARES32 Electrical Tomography can measure and display all the survey parameters at the same time: ground resistivity values, current, voltage, spontaneous potential, induced polarization and indication the quality of the measurement.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Pipe & Duct Inspection Cameras
Pipe & Duct Inspection Camera are video inspection cameras with a probe long enough (roughly 70 ft.) to locate and identify an obstruction in a water or sewer line or HVAC duct by taking close-up video clips and photos of it. The P16PIP probe (also available separately) that comes with the DPS16 Pipe & Duct Inspection Camera has better camera lighting and optics and slightly better resistance to water than the P610-20PR probe that attaches to a recording or non-recording wet/dry inspection camera console.
-
product
PXI 5W Programmable Resistor Module, 2-Channel, 1.5Ω to 3.55kΩ
40-252-023
The 40-252-023 is a programmable resistor module with 2 channels which can be set between 1.5Ω and 3.55kΩ with 1Ω resolution The 40-252 range provides a simple solution for applications requiring up to 5W of power handling per channel. The 40-252 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
product
Piezo-resistive Accelerometer
A Piezo-resistive Accelerometer has a stable structure composed on a silicon chip created by the micromachining and semiconductor production technology. A mass and a beam on which a set of the Piezo-resisters are created on the silicon chip. A set of electrical bridged is formed by such Piezo-resistive resisters to generate signals proportional to the applied acceleration.
-
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
product
IEC60558 Insulation Material Layer Abrasion Resistant Test Device
CX-J16
Shenzhen Chuangxin Instruments Co., Ltd.
This test is conforms to IEC60558-1 Fig6 and IEC60065 Fig14--16.The test shall be performed by fixing the specimens of thin sheets on a mandrel made of nickel plated steel or brass with smooth surface finish.
-
product
PXI/PXIe High Density Precision Resistor Module
42-297A-040
The 40-297A-040 (PXI) and the 42-297A-040 (PXIe) are 6-channel programmable resistors with a range of 2.5 Ω to 102 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
Alternate 2.14 (61.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-72T1-6
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Process Indicators & Field Devices
Field devices from the Field Analog series record and convert signals from resistance temperature detectors, thermocouples, resistance-type sensors, and voltage sensors directly on site.
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2TB-4
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1B-7-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Digital Earth Resistance Tester
Wuhan Fanke Transformer Manufacture Co., LTD
Digital Earth Resistance Tester
-
product
Lightning Current Generator
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
product
Chroma Milliohm Meters
Chroma Systems Solutions, Inc.
The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25T36-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1J-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Gasoline Engine Tachometer
SE-1620
The SE-1620 is an engine tachometer that performs measurement of the number of revolutions of a gasoline engine by connecting an engine revolution sensor such as an ignition pulse detector. A 100-mm wide-angle meter is used for the display, and both analog output and pulse output functions are provided as standard.Simply attach an ignition pulse detector or one of our other compatible detectors to the engine to enable measurement of the number of revolutions of a gasoline engine. The inputs, outputs and input power supply are all isolated to ensure the output of analog and pulse signals with superior noise resistance and stability characteristics.
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1P-8-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
AstroAI Digital Multimeter
TRMS 6000
WIDE RANGE of tests for Voltage, Current, Resistance, Continuity, Capacitance, Frequency; Tests Diodes Transistors, TemperaturePROFESSIONAL LEVEL features include Auto-Ranging capability, and True RMS for measuring both AC Current and Voltage
-
product
Motor Starting & Control Resistors
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Accessories for Earth Resistivity (VES)
Electrodes
Earth resistivity / Accessories for earth resistivity (VES)
-
product
Light 0.75 (21.00) - 2.00 (57.00) Bead Probe
BTP-25HF-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
PXI 2.5W Programmable Resistor Module, 1-Channel, 3Ω to 11.4MΩ
40-251-153
The 40-251-153 is a programmable resistor module with 1 channel which can be set between 3Ω and 11.4MΩ with 1Ω resolution The 40-251 range provides a simple solution for applications requiring up to 2.5W of power handling per channel. The 40-251 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
product
EBIRST 104-pin D-type Test Tool
93-022-001
The 93-022-001 eBIRST 104-pin D-type test tool is part of a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
product
Cable Sheath Testing and Fault Location System
Shirla
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR shirla. Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.* Cable and cable sheath testing up to 10 kVC* Resistance measurement* Cable and cable sheath fault pre-location with precision measuring bridge* Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
-
product
Citric Acid Monitor
HE-960CA