Time Reference
An absolute measure of time.
See Also: Time, Timers, Time Interval, GPS Time, Time Code, Time Domain, Time Standards, Timing, Frequency Synthesizers, Time & Frequency, Clocks
-
Product
Time Domain Analysis
S97010B
-
The S97010B time domain analysis capability allows you to measure the time domain response of a device. The analyzer can transform frequency domain data to the time domain or time domain data to the frequency domain.
-
Product
Time Frequency Analysis Function
OS-0527
-
This function can evaluate transient phenomena that were difficult to capture by FFT analysis, and display clearly time change of the frequency component while maintaining its frequency resolution . The OS-0527 is equipped with STFT (Short Time Fourier Transform) and Wavelet transform.
-
Product
Time Interval/Frequency Counter
SR620
-
Stanford Research Systems, Inc.
The SR620 measures time interval, frequency, pulse-width, rise and fall time, period, phase and events. Time intervals are measured with 25 ps rms resolution, making the SR620 one of the highest resolution counters available.
-
Product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
Product
Real Time Digital Filters
-
Real Time Digital Filters can be used to filter a measured signal in real time. Filter characteristics can be defined by the user to meet the requirements of a specific application. Real-time digital filters are applied in the data conditioning phase. The filters are designed with a graphic design tool and then uploaded to the front-end for real-time calculation. The graphic design tool defines the filter performance vertical axis with a dB scale. The horizontal axis is defined as relative frequency.
-
Product
NTP Time Servers
-
The Masterclock NTP100 family of NTP time servers provide accurate timing to networks and conform to NTPv2 (RFC 1119), NTPv3 (RFC 1306) and NTPv4 (RFC 5905). Each NTP100 device can operate on a local area network (LAN) or act as an enterprise-wide source for legally-traceable time and date distribution, depending upon your network configuration requirements. Masterclock NTP time servers are compatible with IPv4/IPv6 networks and offer AES256 SSH encryption, as well as MD5 authentication, for secure communications.
-
Product
Shaper Of The Reference Frequency
MFC
-
The mezzanine module (mezzanine) of the MFC is designed to reproduce on six output lines high-precision frequency values obtained by dividing the frequency from the built-in reference frequency generator.
-
Product
Rubidium Reference Oscillator
VCH-210
-
The rubidium reference generator VCH-210 is designed to generate a highly stable reference and clock signal.
-
Product
Reference Thermometers
-
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
Product
PCIe Digital Waveform Acquisition with Programmable Threshold - 250 MBit/s Internal Sampling Rate Timing, 250 MBit/S External State Clock
M4I.7720-X8
Digital Waveform
The M4i.77xx-x8 series digital waveform acquisition (logic-analyzer) cards include versions with 32 synchronous channels, either single-ended with programmable threshold levels or differential. The large onboard memory can be segmented to record different waveform sequences. While the M4i.77xx cards have been designed using the latest technology they are still software compatible with the drivers from earlier Spectrum digital acquisition cards. Therefore existing customers can use the same software they developed for a 10 year old 60 MS/s digital input card also for an M4i.77xx series 720 MS/s logic analyzer.
-
Product
Advanced PC/104 Timing Board
PC104-Plus SyncClock32
-
The PC/104Plus SG from Brandywine Communications provides precision time with zero latency to the host computer over the PCI bus. An on-board microprocessor automatically synchronizes the clock to reference signal inputs. The reference signal inputs can be 1 PPS, IRIG or NASA time codes and optionally, GPS or HaveQuick.
-
Product
Timing and Frequency Solutions
-
Arbiter Systems®, Inc. delivers world class GPS based precision timing and frequency solutions for a variety of evolving markets. Engineered and manufactured in the USA, Arbiter precision time clocks and supporting products surpass industry standards in terms of accuracy, flexibility, reliability, connectivity and value, and are as at home in the substation as they are in the laboratory.
-
Product
CPCI timing plug-in
CPCI-SyncClock32
-
The CPCI-SyncClock32 from Brandywine Communications provides precision time with zero latency to the host computer over the CPCI bus in the 3u form factor. An on-board microprocessor automatically synchronizes the clock to reference signal inputs. The reference signal inputs can be 1 PPS, IRIG or NASA time codes and optionally, GPS or Have Quick.
-
Product
Functional/Protocol Debug and Analysis Reference Solution
DDR4
-
Highest confidence in measurement accuracy! Industry’s fastest triggering and data capture for DDR4 analysis, test, and debug.
-
Product
Solution Standard Reference Materials
-
NCS Testing Technology Co., Ltd.
Solution Standard Reference Materials by NCS
-
Product
Multi-wavelength Measurement Optical Time Domain Reflectometer
MT-7300 Plus
-
Guangzhou Wanglu Communications Co., Ltd.
● 32/30dB high dynamic range● ≤2m extra-short event dead zone● 0.05m high distance resolution,128k sampling points● Fast auto measurement, one-button operating● Test up to four wavelengths with a single unit ● Communication light check automatically● Remote function via Ethernet● USB interfaces, supporting USB stick and printer and direct cable download to PC via ActiveSync● Supporting Bellcore GR196 file format in writing or reading● Built-in lithium battery with high capacity for over 8 hours of operating life● Integrated Visible fault locating (VFL)
-
Product
OLED Life Time Test System
-
A system for measuring measurement items (brightness and so forth through Voltage, Current, and Photodiode) and their lifetime in intervals of set time, while supplying power to multiple (32 Channel) OLED panel stably.
-
Product
Laureate Time Interval Meter
Model FRI
-
Configured to time periodic events which produce start and stop pulses from 1 s to 199.99 s over a programmed gate time up to 199.99 s. Timing resolution to 0.2 s. Optional data I/O and relays for alarm or control. Six 0.56" (14.2 mm) high digits, 1/8 DIN case.
-
Product
Reference Magnets And Zero Chambers
-
Reference Magnets with different magnetic field strenghts and dimensions. Available field strenghts ranging from 10mT to 1,4T. We deliver the Reference Magnets with a Factory Certificate. Zero Chambers are required to set zero of gaussmeters. We deliver two different types of Zero Chambers.
-
Product
Military Timing Solutions
-
Brandywine is AS9100C certified and supports the environmental testing and specific interface standards needed for simple integration within military hardware. Brandywine offers many standard options for our military timing products including cesium frequency standards for international applications as well as the option to customize each product to fit your specific timing needs.
-
Product
Reference Transmitter
81492A
Transmitter
Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
Product
Dynamic Digital I/O With Per Channel Timing, Programmable Logic Levels And PMU PXI Card
GX5296
Digital I/O
The GX5296 offers advanced dynamic digital I/O performance and capabilities in a single slot, 3U PXI format. The 32-channel, GX5296 features timing per pin, multiple time sets, data formatting, and an advanced sequencer – providing users with the capability to emulate and test complex digital busses for system, board or device test applications. Offering sub-nanosecond edge placement resolution per pin and a PMU per pin, the GX5296 has the ability to perform both DC and AC parametric testing. Each digital channel can be individually programmed for a drive hi, drive lo, sense hi, sense lo, and load value (with commutation voltage level). In addition, each channel offers a parametric measurement unit (PMU) providing users with the capability to perform parallel DC measurements on the DUT (device under test).
-
Product
Time Domain Reflectometers and S-Parameter Analyzers
Analyzer
The Teledyne LeCroy WavePulser 40iX and the Teledyne Test Tools T3SP15D are a perfect combination of complimentary products to serve the requirements on testing, validating and troubleshooting cables, backplanes, connectors, transmission lines on boards and interconnect.
-
Product
Reference Electrodes
-
PotentioLab reference electrodes provide stable potential control for three-electrode electrochemical testing. Options include Ag/AgCl reference electrodes and laboratory designs for aqueous systems, salt bridge use and compatible custom electrochemical cells.
-
Product
5G Channel Sounding, Reference Solution
-
The 5G Channel Sounding, Reference Solution is a combination of hardware, software, and measurement expertise providing the essential components to accelerate 5G sounding research. This reference solution enables researchers and design engineers to use, enhance, or modify the test platform as required to meet specific test application needs including scalable channel count, flexibility to transmit and measure in mmWave frequencies, wide transmit and analysis bandwidths, and real-time data processing.
-
Product
Enhanced Time Domain Analysis With TDR
S96011B
-
Use S96011B to perform enhanced time domain analysis for high-speed data applications. Includes all functionality of the S96010B (TDR/TDT mode). In addition, the S96011B enables more detailed measurements and evaluations, such as eye diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S96011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, use mechanical calibration kits or ECal with DC option (i.e. N469xD or N4433D with Option 0DC).
-
Product
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe
T3HVD1500-200
-
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe.
-
Product
20 Bit Dual-Channel Reference Source
DRS20
-
The DRS20 is a dual-channel reference source offering ultra high precision and stability and provides a +/-10 V output. The output current can be up to 10 mA and the 4 wire connection provides a 1 µV/mA load regulation. The high precision and stability is achieved by using a temperature controlled voltage reference.
-
Product
Reference Thermapen®
-
Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.