Response
-
product
Sensitivity Testing
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
product
Fine Wire Versatile Thermocouples ANSI
An exposed junction thermocouple is the simplest form of thermocouple. It consists of two pieces of thermocouple wire joined together with a welded bead. Since they can be made very small, an exposed junction thermocouple can provide a very fast response time.
-
product
Linear Polarization Resistance (LPR) Monitoring
The electrochemical technique, commonly referred to as Linear Polarization Resistance, is the only corrosion monitoring method that allows corrosion rates to be measured directly, in real time. Although limited to electrolytically conducting liquids, the response time and data quality of this technique make it clearly superior, where applicable, to all other forms of corrosion monitoring.
-
product
Solid State GaN (Gallium Nitride) Amplifiers
Fairview Microwave’s solid state GaN (Gallium Nitride) power amplifiers (also called SSPAs) feature broad frequency bands ranging from 30 MHz to 7.5 GHz and very high gain levels from 43 to 60 dB. These GaN SSPAs also show impressive harmonic response (-15 to -20 dBc) under worst case conditions. Saturated output power levels range from 10W to 100W with 20% to 35% Power Added Efficiency (PAE). All of our high power solid state GaN amplifiers from Fairview have internally regulated single voltage supplies. Our GaN SSPAs are designed to withstand environmental conditions such as humidity, altitude, shock and vibration with an operating temperature ranges from -40°C to +85°C. Some models are also equipped with integrated heat sinks and cooling fans. Most designs are EAR99.
-
product
Electrochemical Workstations
Besides a potentiostat / galvanostat all our electrochemical workstations include also a frequency response analyzer unit (FRA) in their basic configuration. This makes each of our electrochemical workstations a highly versatile basis equipment for a multitude of electrochemical investigation methods on batteries, accumulators and fuel cells as well as on high impedance objects such as coatings and laminates. Due to their hardware extensions slots our instruments can be extended to multi purpose data acquisition and control test stands.
-
product
Pressure Switches
Our Pressure Switches are; lightweight, miniature in size and low in cost compared to competitive products. At a rated loadyou can expect the pressure switches we supply to provide a fast, repeatable response for millions of cycles.
-
product
GMDSS Radio
NAVTEX System
The NAVTEX system provides the automatic dissemination of local Maritime Safety Information (MSI) by Narrow Band Direct Printing (NBDP) operating in the Forward Error Correction (FEC) broadcast mode (see Section 0 for more details on FEC operation). Depending on the geographical features of its area of responsibility (in main, the length of coastline), the NAVTEX system may be chosen by Administrations as an alternative to providing such information by the Inmarsat-C EGC service.
-
product
Spectral Response (Spectral Sensitivity) Measurement
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
product
Microwave Wideband Externally Modulated Transmitters (without RF Amp)
MT80 (30KHz~40GHz)
Hangzhou Huatai Optic Tech. Co., Ltd.
MT80 series microwave optical transmitter, adopts external modulation technique, are able to transmit 40GHz microwave RF signal with long distance, wide bandwidth, and flat responsibility. They provide an outstanding linearity fiber optical communication for analogue and digital wideband microwave application. Due to avoidance of using expensive coaxial cable or wave guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless; timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 40Gb/s high speed communication system. MT80 adopts low noise, narrow linewidth CW DFB laser as light source; LiNbO3 external modulator as signal modulation, no laser chirp, low dispersion distortion, high extinction ratio, Full-transparency operation mode. It can be applied in long distance and extra-long distance transmission after EDFA.
-
product
PCI Programmable Resistor Card 2-Channel 3 Ohm To 131k Ohm
50-294-034
The 50-294 series of PCI Programmable Resistor cards are available with two channels of 16-bit, two channels of 12-bit or four channels of 8-bit resistor chains in a single card. These cards are ideal for simulating sensors for control and management systems under test, allowing the user to verify system response in design verification or manufacturing test applications.
-
product
Quick Response Time Combustible Gas Leak Detector w/ Alarm
CD200
UEi Test & Measurement Instruments
The CD200 has a long, slim gooseneck probe and a bright LED tip light to find combustible gas leaks in tight areas. Its adjustable alarm, easy one-hand operation and impact resistant storage case add up to value and convenience.
-
product
Multiple-Use Pre-clinical Pressure Catheter
FISO’s catheters offer significant advantages over traditional solid-state catheters, while maintaining an excellent performance in signal integrity and frequency response. The other major benefits of FISO’s catheters include: (i) no side-facing sensor measurement artifacts, which are pretty common near vessel walls, and (ii) the ability to function within an MRI machine, or high EMI/RF environments.
-
product
PIM Testing
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Passive Intermodulation (PIM) is a non-linear response of two or more signals of different frequencies mixing together in a passive device, e.g., antenna, cable, con- nector or splitter. Today, PIM has become a very serious, and challenging issue for mobile operators, equipment vendors, and component manufacturers due to frequency planning in modern communication networks, the usage of high-power transmitters and the usage of more sensitive receivers in base stations. If a PIM with sufficient magnitude generated from a transmitter falls within an adjacent receiver channel, it causes serious interfe- rences to the base station receiver and will significantly degrade the network quality of service.
-
product
Solid State Broadband High Power Amplifier 1900 - 6000 MHz / 200 Watts
2215
The 2215 is suitable for octave bandwidth high power CW, modulated and pulse applications. This amplifier utilizes high power GaN devices that provide wide frequency response, high gain, high peak power capability and low distortions. Exceptional performance, long-term reliability and high efficiency are achieved by employing advanced broadband RF matching networks and combining techniques, EMI/RFI filters, and all qualified components. for EMC, RF Product Test, Communications and Electronic Warfare applications.
-
product
Mobile Comm DC Source w/ Battery Emulation, DVM
66321D
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66321D mobile communications dc source provides fast transient response, exceptional sourcing, output resistance programming, and precision measurement. This product is specially designed for testing next generation digital wireless communications products. The 66321D mobile communications dc source offers a new capability that simulates the internal resistance of a battery or battery pack. Additionally, these high performance models offer improved transient response and stable output operation with either short or long load leads. The 66321D dc source provides all of the capabilities of the 66321B with the addition of a built-in digital voltmeter.
-
product
Vibration Meters
Simple to operate and are ideal for obtaining spot measurements. Features accurate, piezo-electric accelerometer sensor, LCD read-out in acceleration, velocity and displacement and true RMS velocity response.
-
product
Product Range
Solus
Introducing Protea's new range of laser gas analysers - Solus. The Solus platform represents an extension of Protea's spectroscopic gas analysis equipment into laser based technology, allowing for highly selective, quick response and low range measurements of 1 or 2 gases in a cost-effective, re-configurable package. Solus utilises the latest in Tunable Laser Diode Absorption Spectroscopy (TDLAS), together with the best in micromachining technology, to deliver a precisely controlled narrow wavelength that can be tuned over a small range. The narrow linewidth allows for selection of precise spectral absorbance in the NIR region, free from cross-interferences of other absorbing gases. For some tuning ranges, a number of gases can be measured by tuning a single laser diode e.g. NH3 and H2O.
-
product
Force Balanced Accelerometer
PA-23, PA-23BH, S-230
The Geotech Model S-230 is a high resolution, 1-component, force balanced accelerometer capable of meeting the noise and stability requirements of the most demanding seismic studies. It features a very wide frequency response (DC to 90 Hz) and an internal calibration coil. Three S-230 accelerometers are packaged as a borehole 3-component unit (Model PA-23BH) and as a surface 3-component unit (Model PA-23). PA-23BH can be submerged up to 100 m depth.
-
product
Finite Element Analysis (FEA) Solution
Femap
Siemens Digital Industries Software
Femap is an advanced engineering simulation software program that creates finite element analysis models of complex engineering products and systems, and displays solution results. Femap can virtually model components, assemblies or systems and determine the behavioral response for a given operating environment.
-
product
Hardware Enabled SaaS Solution Quantifying Methane Emissions
MethaneTrack™
NevadaNano’s MethaneTrack™ is a low cost network of rugged monitoring points to measure methane emissions and report leak location and size to the operator. Utilizing an Industrial IoT (IIoT) network to detect methane in the air, MethaneTrack™ detects fugitive and operational emissions from a site and immediately alerts the operator of the location and volume of the emissions, facilitating rapid response and repair. Autonomous, continuous monitoring enables up to 99% reduction in emissions while reducing operational costs and boosting profits.
-
product
LXI 24-Channel 1GHz Video Multiplexer
60-721A-001
This High Performance Video MUX is designed for the switching of RF signals in 75Ω systems at frequencies up to 1GHz. It is ideal for 75Ω monitoring applications that require a multiplexer to select one channel to be routed to measuring equipment. The automatic connection of unused channels into 75Ω terminations helps maintain signal integrity and minimizes the possibility of introducing unwanted responses. The common connection is also automatically terminated into 75 Ohm when unused. Front panel LED indicators adjacent to each multiplexer input connector provide an easy visual identification of the active channel.
-
product
Temperature Measurement IR Sensors & Detectors
ST60 High Temperature
A single-channel silicon-based thermopile that will withstand operating temperatures of 225C, with a small active area of 0.61mm x 0.61mm in a TO-5 package. The reduced height package functions as an internal aperture. Two thermistor options provide ambient package temperature measurement. Currently only available with 8-14um silicon window. Time constant of 18ms with Nitrogen encapsulation gas delivers a very low Temperature Coefficient of Responsivity of -0.4%C. This detector has a very short thermal shock response to ambient temperature change.
-
product
S2 Penta Sensors
ULP-S2 PCI/V
Optomistic Products’ best-selling Sensor, the ULP S2 Penta Sensor, is relied upon for its versatility in accommodating most LED color and intensity test applications. Implemented in a unique and customizable 2-Part solution, the S2 Penta Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption:Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsOutput Loads: ‘Int.’& ‘Color’- 2Kohms min., 100pF max.Output Pins: 4 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longTypical response times: Typical response time: <10mS capture time; <100mS overall responsetime for color and intensity simultaneouslyFiber-Optic Probes: Can be paired with any Universal LightProbe Fiber-Optic Probe
-
product
Bio-Mechanical Instruments
It could induce Protective Stepping Responses of Patients with Hemiplegia in responding to Slow or Fast Multidirectional Pulling Perturbations.
-
product
DH Series High-Temperature Solder-In Tip, 16 GHz BW, 3.5 Vpp Range
DH-HITEMP
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
product
43.5W to 66W - Single Output
iBF Series
*DOSA Compatible Footprint*2.4-5.5 Vdc, 4.5-14 Vdc Inputs*0.6-3.63 Vdc, 0.7-5.5 Vdc Outputs*Non-Isolated*Excellent Transient Response*LGA or EPC format*No external loop tuning components needed
-
product
Radar Simulation Software
Pulse Sequencer
R&S®Pulse Sequencer software together with a vector signal generator from Rohde & Schwarz or just as software provides a compelling radar signal generation solution to engineers and technicians responsible for testing radar receivers. The solution is in line with the trend of testing more in the lab rather than expensive field testing. Co-engineered with the industry, the solution supports all relevant modern radar scenario test cases and can account for real-world environments. It uses commercially available R&S®Pulse Sequencer PC software and off-the-shelf Rohde & Schwarz vector signal generators.
-
product
Solar Array Simulator DC Power Supply
62000H-S
Chroma Systems Solutions, Inc.
Solar Array Simulator DC Power Supplies by Chroma provide programmable simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000S-H series provides an industry leading power density in a small 3U high package. The Solar Array Simulator is highly stable and has a fast transient response design, which are both advantages to MPPT performance evaluation on PV inverter devices.
-
product
Atomic Force Microscope
NX-Hivac
Park NX-Hivac allows failure analysis engineers to improve the sensitivity of their measurements through high vacuum Scanning Spreading Resistance Microscopy (SSRM). Because high vacuum scanning offers greater accuracy, better repeatability, and less tip and sample damage than ambient or dry N2 conditions, users can measure a wide range of dope concentration and signal response in failure analysis applications.
-
product
15-CH Isolated Digital Output Module
ND-6056
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.





























