Showing results: 286 - 300 of 1079 items found.
-
Dotcom-Monitor
Establish response time baselines under specific user load numbersIdentify performance bottlenecks as the number of simultaneous users increasesFind upper limits of current systems to plan for future capacity (Capacity Planning)Stress your production environment to see how and when things fail
-
DS Instruments
Using a Spectrum Analyzer (SA) in combination with a Tracking Generator (TG) enables swept scalar frequency response measurements of active and passive networks.
-
Columbia Research Laboratories
The force balance accelerometer has a classical critically-damped, second-order frequency response. There is no peaking in the response but simply a smooth roll-off above the natural frequency. This property along with the excellent characteristics of the "HP" torquer design makes Columbia accelerometers the best choice for demanding applications where precise DC and near-DC measurements are needed in demanding shock and wide band vibration environments. Columbia force balance accelerometers are available to cover virtually all applications. Low noise, high output units can be used for seismic structure motion studies while miniature, high range versions are optimum for measuring more violent high G environments encountered in many industrial, aircraft and missile applications.
-
ARO-PR -
JFE Advantech Co., Ltd.
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
786888-01 -
NI
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Renesas Electronics Corp.
Renesas' MIL-STD-883-compliant monolithic, quad, precision comparator is qualified to QML Class Q military standards and offers fast response time, low offset voltage, low offset current and virtually no channel-to-channel crosstalk for applications requiring accurate, high-speed, signal level detection.
-
M6 -
Seismic Source Co.
*Built-in damping and overrange stops*Safe overrange limits*Force up to 2000 G without damage to sensor*Temperature compensated for accurate response over entire temperature range*High slew rate operational amplifiers (1.2 V/usec)*Internal RF shielding on each pin
-
Analog Devices Inc.
Analog Devices envelope/peak detector products provide a versatile solution with state-of-the-art accuracy for communications, space, military, and other markets. Members of this portfolio offer high rms accuracy and fast envelope response, while operating in multiple temperature ranges to suit commercial and industrial needs.
-
Analog Devices Inc.
Analog Devices high speed comparators feature <100 ns propagation delay and are a versatile and easy to use solution for a range of applications. Owing to our proprietary CB and XFCB fabrication processes, our comparators such as the AD790 possess a fast response time with outstanding input voltage resolution.
-
TS-2800 -
Ono Sokki
The TS-2800 is a torque meter for phase difference type torque detectors. Can be used with our long-selling torque detectors SS/DD series and high accuracy, high response type TH series. Since all signals are digitally processed, torque measurement can be performed with great stability, reproducibility and linearity.
-
FX2 -
Panasonic Industrial Devices Sales Company of America
The FX2 Series Fiber Sensor has multiple amplifiers. The FX-A3R has a 15us high speed response time and is suitable for detecting small objects or objects traveling at high speed. The FX2-A3R-LED is an LED sensing type amplifier, which can detect weak lighting from LEDs.
-
G5.BAS -
Regatron AG
The G5.BAS series is bidirectional regenerative. It was developed specifically for the simulation of energy storage devices and batteries and is suitable for use in laboratories and on test benches. The modular and finely graded G5.BAS series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3.
-
MultiDimension Technology Co.,Ltd.
Are adaptive to installation height and tape width with excellent protection against magnetic material interference. Incorporating tunneling magnetoresistance (TMR) technique, the AGV-TMR15X series are designed to provide excellent temperature characteristics, good consistency, fast frequency response, high sensitivity and low power consumption performance.
-
D4000AERB -
Keysight Technologies
MIL-STD 1553 and ARINC 429 trigger and decode for the InfiniiVision 4000 X-Series oscilloscopes, along with mask testing, frequency response analysis, and video analysis
-
ST150 Quad -
Dexter Research Center, Inc.
A four-channel silicon-based thermopile detector in a TO-8 package. Each active area size is 1.5mm x 1.5mm. Affordable four-channel design with strong output and a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.