Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
KVZG -
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
Rishabh Instruments Pvt. Ltd.,
Rish Nano CT is a very reliable, efficient and robust current transformer for measurement of AC current. It provides 100 mA AC output. It can be used in Circuit breakers. Earth Leakage Protection.
-
MCL-1100D -
MULTI MEASURING INSTRUMENTS Co., Ltd.
This handy type clamp tester has the biggest CT window in the world (108mmx128mm) and can measure AC load current and leakage current (0.1mA-3000A) just by clamping the conductor without disconnecting the circuit.
-
KM 1520 -
Kusam Electrical Industries Limited
*Capable of measuring earth voltage(Vac).* 2 mA measuring current permits earth resistance to test without tripping earth leakage current circuit breakers in the circuit.* Battery operated.
-
SCAR 10 -
Altanova Group
This MOV- Metal Oxide Varistor test system is the perfect device to perform analysis and diagnostics on metal oxide arrestors. It is supplied with a special current clip-on transformer designed for the measurement of current leakage.
-
ComSonics, Inc
ComSonics' QAM Shadow is targeted for in-building leakage detection and ingress mitigation when portability and ease-of-use is most important.contractor work verificationevaluate new property wiringingress detection and mitigationextremely easy to use with one-button operationDOCSIS 3.1 ready to future proof your investmentbuilt-in near-field antenna eliminates the need for external antennas
-
CM3286 Series -
HIOKI E.E. Corp
Measure power ranging from 5 W at a low current of 60 mA to 360 kW. In addition to current, voltage, and power, measure simple integral power consumption and phase sequence. Discover manipulation of electric meters by comparing meter and integral power consumption measurements. Discover theft by measuring leakage current.
-
DCA55 -
Peak Electronic Design Ltd.
Intelligent and flexible semiconductor analyser. Connect any way round! The DCA55 then displays the following on its backlit alphanumeric display:- Component type (such as NPN transistor, P-Ch MOSFET, LED, diode etc)- Pinout information (such as Base, Emitter, Collector etc)- Parameter measurement (hFE, Vbe, Vf, leakage current etc)
-
KT-5000Pi -
Kast Eng Co. LTD.
This is a Hipot(Puncture) Tester combined with Insulation Tester in a set.It tests 2 kinds of test continuously in sequence, and any of both hipot or insulation test can be set to test first in other by the selection switch.Hipot Tester has the leakage current meter, so the operator can check the leakage value while testing. And the preset procedure of the Insulation Tester is very easy. Both tester judge the product to be good or bad automatically in a short time.This tester has many I/O ports to connect extra test system. Price : 2,550 (USD)
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed TESTING SET UP FOR SINGLE PHASE / THREE PHASE MOTOR for carrying out Performance Test, Earth Contact Resistance Test, High Voltage Test, Megger Test and Leakage Current Test. It consists of Voltmeters, Ammeters and Wattmeters for observing the values of different parameters. OK / NOT OK lamps are also provided to display the results of Earth Contact Resistance Test, HV test, Megger Test, Leakage Current Test. All tests are provided with tripping cut off concept.
-
UI9600 -
Lisun Electronics Inc.
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
PULSOR -
LEMSYS
Portable maintenance testers Pulsor 2kV, Pulsor 4kV, Pulsor 7kV To measure Leakage current ID, IR in given voltage range of power components: IGBTs, MOSFETs, Diodes, Thyristors, Varistors…
-
AMIC-5010 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits
-
AMIC-10k1 -
Amperis sl
Insulation resistance measurement - 40TΩ: * 50 - 1000 V, in 25 V steps, * 1000 - 10000 V, in 50 V steps ; Memory, bluetooth keyboard option, heating location ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits.