Showing results: 46 - 60 of 440 items found.
-
Mitsubishi Electric Automation, Inc
Like molded case circuit breakers, these circuit breakers are utilized to open/close low-voltage circuits and protect wiring by automatically closing circuits when they''re overloaded or if a short-circuit occurs. We offer a comprehensive range of circuit breakers that provide superior performance in electrical protection, isolation and power distribution applications. Our circuit breaker products comply with various standards such as JIS, IEC, EN, GB and UL/CSA, and with easy to install accesories, the Mitsubishi Electric circuit breakers are "user-friendly" and ensure the best solution for virtually every application.
-
Nanjing ELIKE Meter Co, Ltd.
Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery
-
M-1141 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency(fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
SK-7820/SK-7825 -
Kaise Corporation
Wide range from 40mA to 100A AC,Conductor dia. : φ24mm max (SK-7820), φ40mm max (SK-7825)AC voltage measurement.Vibration alert comparator.(The function to show the comparator result by buzzer and vibration which is convenient innoisy surroundings.)
-
DU2316/2317 -
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
CLT200 -
Matco Tools
Quickly locates internal engine problems such as bad rings, valves and leaking head gaskets. Dual 2-1/2" heavy duty gauges with protective outer boots. Scales read 0-100psi and 0-700 kg/cm2Pressure regulated manifold includes high quality quick couplers for fast set-ups.
-
B2201A -
Keysight Technologies
The B2201A reduces the cost of test by enabling characterization tests to be automated, with only slight compromise to the measurement performance of the semiconductor parameter analyzer. It supports a 4-SMU, full-Kelvin configuration and a capacitance meter, with room for future expansion. Includes 14 inputs, each with a unique internal measurement path, and a distinctive capacitance measurement compensation feature for two of the inputs. Provides front panel control via keypad or optional light pen, and supports instruments such as pulse generators.
-
B2200A -
Keysight Technologies
The B2200A reduces the cost of test by enabling characterization tests to be automated, without compromising the measurement performance of the semiconductor parameter analyzer. It supports a 4-SMU, full-Kelvin configuration and a capacitance meter, with room for future expansion. Includes 14 inputs, each with a unique internal measurement path, and a distinctive capacitance measurement compensation feature for two of the inputs. Provides front panel control via keypad or optional light pen, and supports instruments such as pulse generators.
-
Electrical Char -
Frontier Semiconductor, Inc,
Full line of front end electrical characterization tools: Sheet Resistance, leakage, and CV-IV measurements.
-
M-340IRV -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Palm size mini clamp type.・High accurate measurement with min. resolution 0.001mA.
-
MCL-500IRV -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・True RMS measurement (I, Io, V).・With filter switch to cut high frequencies.
-
MCM-8000 -
Taurus Powertronics Systems
By connecting optional CT sensors, the instrument can measure and memorize leakage current of 8 circuits at the same time and the memorized data can be seen even during measurement.
-
MCM-8000 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
●The leakage current of max.8 circuits at the same time.●Easy for data management (storage by CSV formula)●Cost performance, high-speed sampling with high-frequency cut function.
-
MCL-800IRV -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・Calculable insulation resistance value(MΩ)by voltage & current (only in case of using direct voltage input sensors)・Available measurement for 3P/4W star connection.
-
DCZCT-11M -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC Earth Leakage Current Measurement *Bipolar DC ±12V Power Supply*Output DC ±1.5V at DC 10mA *Isolated Housing Case based on UL94V-0*Through Hole PCB Mount Type, Exciting Current Method