Pulse Current
-
Product
Split type Pulse Current Sensor
OKM-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For pulse current detection.
-
Product
Split type Pulse Current Sensor
PCT-06
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
Product
Split type Pulse Current Sensor
CTF-05M
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Through hole type CT.*Open collector output.
-
Product
Split type Pulse Current Sensor
CTF-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Suitable for the operation and cable continuity check of the equipment by pulse current detection method. Wide AC current range from 0.1mA to 8A. Ultra compact and light weight. High sensitivity and least affection from external magnetic field.
-
Product
Pulse Current Generator Multi-Pulse Generator
-
Shanghai Guantu Technology Co., Ltd.
What is the difference between ordinary current and pulse current?The difference between ordinary current and pulse current: ordinary current is continuous and uninterrupted current.Pulse current is a current whose direction does not change and whose intensity changes periodically with time.
-
Product
Primary Cable Fault Locating
Directional Impulse Detector
-
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-8010A
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
Product
Other Power Electronic Capacitors
-
AC/DC Power Film Capacitors, DC Pulse Current Capacitors, DC Filter Capacitors, Pulse Grade Capacitors, Motor Run Capacitors, Feed-Thru Capacitors and other Customized Capacitors
-
Product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Low Inductance BNC Cable, VOLT:DC 60V
PX0105A
Coaxial Cable
The Keysight PX0105A is suitable for narrow current pulse measurement down to 10 μs pulse width. It supports the Keysight M9602/03A.
-
Product
Measurement System For Testing & Binning Of Back-End LEDs
TP121-TH
-
The photometric specifications of LEDs must meet very high tolerance requirements regardless of whether they are to be used in general, automotive or other specialist lighting applications. This is often a problem since the manufacturing tolerances of LEDs can be higher than those permitted in the end-use applications. Also, LED binning by LED manufacturers in order to classify LEDs based on their tolerances is performed with flash mode testing using pulsed current flow. However, end-use applications of the LEDs often operate in constant current mode and with significant thermal effects. The sophisticated LED processing industry therefore requires measurement devices that can be used for both manufacturer-compliant pulsed mode, as well as constant current operation mode. When the LEDs are run in constant current mode, the junction temperature has significant influence on the performance and lifetime of the LED. Therefore, test systems should be able to test the LEDs at specific junction temperatures.
-
Product
Partial Discharge Detecting Detectors
-
Hangzhou Xihu Electronic Institute
Including pulse current PD detecto, high frequency PD detector, transient earth PD detector, ultra high frequency PD detector, and ultrasonic PD detector.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
High Current SMU Family 2000 A
AXC76xx
-
Generate very short, fully regulated current pulses from 2 ms to DC with up to 2000 A. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
TriaxM-TriaxM, Low Noise Triaxial to Triaxial Cable for SMUs, 1 m
785659-01
Triaxial Cable
The TriaxM-TriaxM Triaxial Cable connects your system to PXI Source Measure Units and other devices that have a triaxial connector. It uses guarding to remove the effects of leakage current and parasitic capacitance when … measuring very low current signals. The cable offers 300 V DC maximum voltage, 3 A maximum continuous current, 10 A maximum pulsed current, and different lengths.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-600B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Pulsed Source Measure Unit
-
The SpikeSafe SMU is a precision pulsed source measure unit that precisely sources pulsed current and simultaneously digitizes voltage. Optimized for precise and repeatable high-power LED and laser testing, SpikeSafe™ SMU (Source Measure Unit) current sources deliver precise pulsing with low microsecond rise times, low-jitter triggering and integrated digitizer for more accurate and repeatable high-power LED and laser testing.
-
Product
High Voltage Snubber Capacitor
STP-01RN / STP-01RB
-
This series of capacitors is Plastic Enclosure, Dry construction design and doesn't have leakage problem when compared with traditional Metal Enclosure Oil impregnated capacitors.Handle high surge current, RMS current and surge voltage with Temperature up to +105CCapacitance : 0.25uF - 60uF ( can be customized )Voltage range : 900Vdc to 5,300Vdc / 280Vrms to 1,600VrmsRMS Current - Irms : up to 80Armspeak to peak pulse current - Ipp : up to 15,000AppTemperature ranges : +85C / +105C
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1200B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
-
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-200B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Precision Pulsed Current Sources
SpikeSafe Performance Series
-
SpikeSafe™ Performance Series Current Sources supply DC and precision continuous or single pulse current for light measurement and other applications. With sustained output power and no duty cycle limitations, Performance Series Current Sources support a broad range of applications.
-
Product
Premium Data Loggers with 1-4 Channels
-
Premium Data Loggers for temperature, humidity, co2, atm. Pressure, voltage, current, pulse and 2-state inputs.
-
Product
Diode Laser Driver
D200
-
The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.
-
Product
Milliohm Meters
Chroma 16502
-
Chroma Systems Solutions, Inc.
With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.
-
Product
Pulse Initialization Demo Board
TMR9112
-
MultiDimension Technology Co.,Ltd.
The TMR9112 demo board was developed to support evalution of the TMR9112 single-axis sensor. The demo board comes with the fast bipolar current pulsing circuit needed for initialising the TMR9112 sensor, and it can be powered from a USB port or any external 5V power supply. For user convenience, the demo board has an optional on-board timer clock with four selectable frequency settings. The On-board timer clock and frequency output can be enabled using the jumper pins. This demo board is divisable along the dotted line so that the sensor board can be seperated from the pulsing circuit board.
-
Product
Counter And Rate Meters
-
We carry a wide range of counter and rate meters including totalizers, batch controllers, and more. Available with pulse, magnetic or DC pulse, analog, voltage, current, and frequency input types.
-
Product
Pulse Width Extender
TLP-8012A5
-
High Power Pulse Instruments GmbH
*Pulse width extender for the high current TLP/HMM test system TLP-8010A and TLP-8010C*6 manual selectable pulse width: 5, 10, 50, 100, 200 and 500 ns*High pulse output current up to ±80 A*High performance and high quality components
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.3S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)