Pulse Current
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Condenser for General Applications
PECA1
-
Lifasa - International Capacitors, SA
These capacitors are designed for application in circuits in which they are subjected to non-sinusoidal voltages and pulsed currents, such as, for example, switching and damping circuits. They can also be used as discharge and filtering capacitors, as well as for any DC application. This capacitor is especially suitable for applications in which a high life expectancy is required.
-
Product
Pulse Initialization Demo Board
TMR9112
-
MultiDimension Technology Co.,Ltd.
The TMR9112 demo board was developed to support evalution of the TMR9112 single-axis sensor. The demo board comes with the fast bipolar current pulsing circuit needed for initialising the TMR9112 sensor, and it can be powered from a USB port or any external 5V power supply. For user convenience, the demo board has an optional on-board timer clock with four selectable frequency settings. The On-board timer clock and frequency output can be enabled using the jumper pins. This demo board is divisable along the dotted line so that the sensor board can be seperated from the pulsing circuit board.
-
Product
Transforming Analog Circuit Breaker Testers
MAC-21
-
The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.
-
Product
120 A High Voltage 50 Ω Pulse Generator
TLP-12010C
-
High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
Product
High Voltage Snubber Capacitor
STP-01RAN/STP-01RFN/STP-01RFB
-
This series of capacitors is Plastic Enclosure, Dry construction design and doesn't have leakage problem when compared with traditional Metal Enclosure Oil impregnated capacitors.Handle Medium Frequency range, high surge current, RMS current and surge voltage with temperature up to +105CCapacitance : 0.1uF - 15uF ( can be customized )Voltage range : 1,200Vdc to 17,000Vdc / 350Vrms to 6,900VrmsRMS Current - Irms : up to 100Armspeak to peak pulse current - Ipp : up to 5,900AppTemperature ranges : +85C / +105C
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-400B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
DC Pulse Current Capacitor
-
Both series can be customized as Low Voltage High Capacitance High Current Capacitors.We can customize Snubber Capacitor as Box type and support other parameters.For 250Vac~900Vac / 400Vdc~1,350Vdc and with higher Current requirement, please refer to our AC/DC Power Capacitors.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
Product
Milliohm Meters
Chroma 16502
-
Chroma Systems Solutions, Inc.
With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.
-
Product
8 Channel Portable Data Acquisition Logger w/ 5" Touchscreen
Titan S8
-
The Titan S8 portable data acquisition logger combines industrial toughness with scientific accuracy to create a powerful, versatile standalone logger. In any environment, from the laboratory to the factory floor, the Titan S8 simplifies complex validation tasks with its eight input channels and a full-color, user-friendly touchscreen interface. No matter the task, the Titan S8 brings valuable, real-time temperature, pulse, current, and voltage data to users’ fingertips without any need for a PC. The Titan S8 is the ultimate companion for any service, equipment, or compliance engineer. Its handheld portability and shock absorbing boot empower users to bring powerful, instantaneous data acquisition wherever it is needed.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-3010C
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±8 kV*High pulse output current up to ±30 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components
-
Product
Milliohm Meter
16502
-
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
Product
Split type Pulse Current Sensor
CTF-05K
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Clamp type CT.*Open collector output.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
High Voltage Film Capacitor
STHVP/STHVE
-
High Voltage Pulse Current for medium frequency applicationHigh Voltage DC / AC Voltage applicationCapacitor can be discharged at rated voltage directly without any protective component and with ambient Temperature up to +105CHigh Voltage Decoupling and SnubberingVoltage MultiplierInduction heatingAct as discharge capacitor to trigger laser, X-Ray and Tesla CoilFor high voltage capacitor bank or arrayHigh Voltage Power Supplies
-
Product
Premium Data Loggers with 1-4 Channels
-
Premium Data Loggers for temperature, humidity, co2, atm. Pressure, voltage, current, pulse and 2-state inputs.
-
Product
Potential Meters
-
Potential meters are basically electrometers which have extremely high input resistances in order to keep the feeding reference electrode free of load. This is necessary to maintain the true potential. pH - meters can be used as potential meters when fast reading is not required, because common pH meters are very slow. When the potential answer to current pulses is to be followed, potential meters are essential.
-
Product
High-Voltage Time-of-Flight Pulsers
-
Are high-voltage pulse generatorscapable of driving 50 (or higher) loads and operating over a wide pulse width range. The instruments include IEEE- 488.2 GPIB and RS-232 interfaces. For diode loads, thesemodels can be used to provide up to 1, 2, 4, 5 or 8 Amps of pulsed current if the diode is connected in series with 50. All models operate over a wide pulse width range of 100 nsto 100 us.
-
Product
High Voltage Film Capacitor
STHVF
-
We manufacture High Voltage Film Capacitors for wide variety of High Voltage power applications with different rated Capacitances, Voltages, Discharge Energy, dv/dt, Pulse Discharge Currents, RMS Currents, Frequency ranges, size restriction, temperature ranges and even capacitor configurations.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
Product
High Current SMU Family 2000 A
AXC76xx
-
Generate very short, fully regulated current pulses from 2 ms to DC with up to 2000 A. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
1-Pin BNC Male to 1-Pin BNC Male Triaxial Cable
785659-01
Triaxial Cable
The TriaxM-TriaxM connects your system to PXI Source Measure Units and other devices that have a triaxial connector. This cable uses guarding to remove the effects of leakage current and parasitic capacitance when measuring very low current signals. The cable also supports 300 V DC maximum voltage, 3 A maximum continuous current, and 10 A maximum pulsed current. Additionally, the TriaxM-TriaxM is available in different lengths.
-
Product
Split type Pulse Current Sensor
PCT-06
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Reflectometer
T-510
-
Techno Instrumentation (India) Private Limited
Pulse Echo, Impulse current and Decay methodprovided to get the distance to almost all typesof faults.Laptop based 15 inch display with user friendlyinterface for easy operation.Online support of experts to review fault graphs.Comparison feature of any 5 graphs for reviewand analysis to get more accurate results.Velocity of propogation(VOP) control makes iteasy to precisely pre-locate faults in cables withdifferent velocity.Automatic storage of more than 10,000 faultgraphs.
-
Product
SpikeSafe DC / Continuous Pulsed Current Sources
-
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
Product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Condenser for General Applications
PECA2
-
Lifasa - International Capacitors, SA
These capacitors are designed for use in circuits where they are subjected to non-sinusoidal voltages and pulsed currents, such as switching and damping circuits. They can also be used as discharge and filtering capacitors, as well as for any DC application. This capacitor is especially suitable for applications where a high life expectancy and a high RMS current are required.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-8010C
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components





























