Pulse Current
-
product
CC30100X, 100 MHz, 30 Arms Current Oscilloscope Probe
785562-01
The CC30100X, or Hioki 3276, is a clamp-on current probe that offers a wide DC to 100 MHz bandwidth and 30 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
HPC High Current Probe
HCP-13
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
C Series Voltage And Current Input Module
The C Series Voltage and Current Input Module features up to 16 input channels with built-in noise rejection. You can use this module to combine the two most common inputs to reduce the overall number of modules you need in your measurement system.The C Series Voltage and Current Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
NI-9266, 8-Channel C Series Current Output Module
785047-01
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
product
AC / DC Current Probe, 100 KHz, 100 A
1146B
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
product
CC3050X, 50 MHz, 30 Arms Current Oscilloscope Probe
785561-01
The CC3050X, or Hioki 3273-50, is a clamp-on current probe that offers a wide DC to 50 MHz bandwidth and 30 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor … controllers. The probe requires an external power supply.
-
product
NI-9227, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module
781099-01
50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
CC15010X, 10 MHz, 150 A Current Oscilloscope Probe
786849-01
The CC15010X, or Hioki 3274, is a clamp-on current probe that offers a wide DC to 10 MHz bandwidth and 150 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-02
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module
783589-01
50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-01
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
product
Pulse Width Extender
TLP-3011C
High Power Pulse Instruments GmbH
*Fully automatic pulsewidth extender*Pulse width up to 1.6 µs in 68 programmable steps of 25 ns*Ultra fast 50 Ω pulsewidth extension with typical 100 ps rise time*High pulse output current up to ±40 A*High performance and high quality components
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Brute High Current Probe
P4301-2F
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Pulse
*MODBUS Master RS485 / RS232*Up to 10 slaves or 15 registers per slave*Monitoring and supply of power to the sensor*Local and remote configuration
-
product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
sbRIO-9207, Non-Enclosed, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781069-01
Non-Enclosed, 500 S/s, 16-Channel C Series Voltage and Current Input Module - The sbRIO‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection. Non-enclosed modules are designed for OEM applications.
-
product
Pulsed Power
Alpha-Omega Power Technologies, LLC.
Alpha-Omega Power Technologies (AOPT) specializes in high voltage pulsed power design and manufacturing. AOPT has industrial proven design ranging in power from a few hundred watts up to 50 kilowatts. We can design and build a complete turn-key system to meet your requirements. Please Contact Us to discuss your requirements.
-
product
Pulsed Transmitter
Built to operate in harsh environments, the Pulsed Transmitter unit provides radar installation decoy protection in a compact footprint and is powered by a Dewey Generator.The unit is comprised of a power supply, power amplifier, signal generator and antenna, with a fiber optic command and control interface providing throughput speeds capable of 1.25 G bits/sec via 1310 nm, single mode, ruggedized fiber.
-
product
CC0550X, 50 MHz, 5 Arms Current Oscilloscope Probe
786846-01
The CC0550X, or Hioki CT6700, is a clamp-on current probe that offers a wide DC to 50 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor … controllers. The probe requires an external power supply.
-
product
Pulse Air-Gun Ionizers
EC-G Series
Panasonic Industrial Devices Sales Company of America
With the new Pulse Air-Gun Ionizer from Panasonic, operators can comfortably neutralize static electricity while manually cleaning. The Pulse Air-Gun’s light-weight, ergonomic design combined with an oil and heat-resistant 2m cable makes it ideal for use at the production line.The Air-Gun Ionizer is equipped with a white LED on the front of the Gun to illuminate target objects. It has three air emission modes: long pulse, short pulse and continuous emission. Ionized air can be emitted at high pressure (range 0.05 to 0.50 MPa), neutralizing static charges and removing dust simultaneously and swiftly.
-
product
Pulse Evaluation Systems
*Intuitive, user-friendly handling*Integrated wide-range power supply*Easily programmable output functions*Devices for monitoring standstill, speed, direction, slip, and frequency*Switching relays and transistor outputs, scalable analog output
-
product
NI-9207, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781068-01
500 S/s, 16-Channel C Series Voltage and Current Input Module - The NI‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection.
-
product
Pulse Acquisition Board
MS 1818
*Used to measure the amplitude of discrete pulses driving relay coils/motors*Programmable No. of samples acquisition with programmable trigger option*Converts sine wave to square wave for pulse measurement*Measures amplitude of sine wave*16 Bit ADC interface*16 Bit data bus host interface*FPGA based design with flexible configuration*1K FIFO Storage
-
product
Pulse Generators
Dedicated analogue pulse generators and function generators with true pulse capability.
-
product
Nanosecond Pulsed Lasers
Our nanosecond pulsed lasers feature pulses in the ns range. For picosecond and femtosecond lasers please see Ultrafast Lasers.
-
product
Pulse Generators
Active Technologies Pulse Generators can be used to set up continuous or triggered pulse streams and offers flexibility to address the most challenging applications like big physics, automated testing, microwaves, modulators, wireless communication, medical and chemistry.
-
product
Light Pulse Generators
Berkeley Nucleonics Corporation
The optical equivalent to electrical pulse generators with rep rate, delay, width and amplitude control.