Local Loop
-
Product
Loop Antennas
-
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
Product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
Analog Output Module
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Radiating Loops
-
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Linear Bench or Rack Mount Power Supplies Programmable, Local or Digital Control, Ultra Low Ripple/Noise
Series PCX-MAT
-
These voltage stabilizers with a full complement of meters and controls, are 1/6-rack size units designed to plug directly into their own carrier cases and rack adapters. Seven models are available. These power supplies offer ultra low noise and ultra low ripple at the output and are MIL-STD-461 compliant. A modular version of PCX-MAT called PCX is also available. Contact Kepco for details.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
mA Loop Calibrators
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Product
Bipolar Power Supplies High Power, 4-quadrant, Analog/Digital/Local Control, Low Ripple/Noise
Series BOP-MG/ME, BOP-EL/GL
-
The BOP High Power are true 4-quadrant programmable voltage and current power supplies. 4-quadrant operation means that they are capable of both sourcing and sinking power. These bipolar power supplies pass smoothly through zero to provide ± voltage and ± current. The BOP High Power use switch mode technology for low dissipation and function as regenerative (recuperative) loads and connected to an active load.
-
Product
Model QLS 4-20 mA Loop Splitter / Retransmitter
-
Generates up to four individually grounded and individually adjustable 4-20 mA loops from a single 4-20 mA or 0-10V input. Overcomes problems which occur when the same 4-20 mA signal is applied to multiple loads in series. Allows outputs to have different grounds, and allows individual loops to be opened without affecting signal to other loads.
-
Product
Dual Loop Master Controller
-
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
Product
High Voltage Linear Power Supplies Bipolar 4-quadrant, Analog/Digital/Local Control, Ultra Low Ripple/Noise
Series BOP-HV
-
The Kepco Model BOP 500DM and BOP 1000DM are high voltage power sources, up to 500V or 1000V, respectively. These combine the capabilities of fast programmable power supplies with a Class A output stage, which can respond bidirectionally from zero. The BOP-HV can be operated in either a "voltage stabilizing" or "current stabilizing" operating mode (selectable by a front panel switch). These power supplies offer ultra low noise and ultra low ripple at the output and are MIL-STD-461 compliant.
-
Product
Embedded Local Oscillator Capability
S93084B
-
The S93084B tunes the network analyzer’s receivers to the output frequency of the converter under test without having to access internal LOs or a common reference signals. For converters with embedded LOs, this enables measurements of match-corrected conversion loss/gain and absolute group delay (requires S93082B and S93083B), gain compression versus frequency (requires S93086B), intermodulation distortion (requires S93087B), and noise figure (requires S93029B).
-
Product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
Analog Output Module
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Loop Antennas
-
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
Product
Current Loop Data Loggers
-
This data logger can measure and store 4~20mA DC current readings automatically. The professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.
-
Product
Milliamp Calibrators & Loop Calibrators
-
Practical Instrument Electronics, Inc.
PIE has milliamp calibrators to fit your needs from the PIE 334 with the basic functions of a 4-20 milliamp calibrator to the advanced loop troubleshooting capabilities of the Model 532. And PIE milliamp calibrators are the only models with patented Loop Diagnostic Technology! All the loop calibrators have fuse-less protection, rugged design, long battery life. Calibrate in the units matching your instruments by displaying in milliamps and percent (%) of 4 to 20 milliamps.
-
Product
Loop Testing
-
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
-
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
Product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
-
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Product
Short Circuit Loop Impedance Meter
AMZC-305
-
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
Product
Software Localization Testing Services
-
Offer Impeccable Globalization and Internationalization Testing Services for software, applications and websites
-
Product
Line Loop Tester
8455
-
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
Product
Sound Source Localization
-
In order to optimize product sounds, it is necessary to know the exact point of origin of a sound source. This makes possible to identify the cause of disruptive sound components and rectify these effectively, optimize sound radiation and thereby achieve the desired sound experience. The ease of use and advanced beamforming algorithms of the HEAD VISOR acoustic camera allow sound sources to be located precisely at the blink of an eye.
-
Product
ThePoint - Loop Powered Level Switch
-
ThePoint Loop Powered two wire level switch provides a current output and has hazardous area approvals making it a good choice for most of your point level application requirements. ThePoint level sensing device offering is suitable for most temperature, pressure, and material types.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
DDS Phase Locked Loop Synthesizer
DDS Series
-
*Connectorized Package *Programmable Frequencies to 1 GHz
-
Product
Loop Powered Trip Amplifier With Dual Relay Output
SEM1636
-
The SEM1636 monitors a (4 to 20) mA loop and provides two independent change over trip contacts set to trip at any point within the (4 to 20) mA range.
-
Product
Helmholtz Coils / Radiating Loops
-
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
Product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.