Sound
tympanum, bioacoustic sensed pressure waves.
See Also: Ultrasound, Audio, Infrasound, Reverberation, Acoustic, Sound Calibration
-
Product
Online Audio Frequency Signal Generator
WavTones
-
We are proud to offer not only the best audio frequency signal generator on the net, but also a high-end sound generator, which compares favorably to the more expensive software and hardware tone generators!
-
Product
Benchtop pH/Conductivity Meter
LAQUA PC1500
-
Ideal for routine applications and student training.Good value for money: no fancy bells and whistles which sounds good but are rarely used.
-
Product
Audio Test Software
-
1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)
-
Product
Multi-Function Portable Induction Test Voltage Tool
WILK301
-
Wenzhou Zhengyuan Electronic Co., Ltd.
Fast live/neutral wire identification with sound and light indication for safe electrical work. (Model WILK301)
-
Product
Siren/Voice Drivers & Recordable Modules
-
Features high quality digitally pre-recorded voice messages and loud attention getting siren sounds.
-
Product
Sensitivity Testing
-
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
Product
Hi Pot Meters
-
The HI Pot Device is designed to Hi Pot de-energized 15kV class cables. The tool transforms 18 Volts from the battery to approximately 8,000 volts DC. When the battery is installed and the safety switch is in the closed down position, the unit is in voltage detection mode. The unit should be in this position when installing the device, as it will sound a warning alarm if you approach an energized source. When the safety switch is lifted and the toggle switch is switched up, the unit is in the Hi-Pot mode and the high voltage DC is being applied.
-
Product
Finite Element Analysis
-
Response Dynamics Vibration Engineering, Inc.
An understanding of structural dynamics is very important to sound Finite Element Analysis (FEA). We have been performing FEA analysis for over 30 years and in most cases we have used experimental data to guide our modeling. While our engineers have had undergraduate and graduate courses in FEA, it is the years of modeling and analysis of existing structures that has taught us the most by forcing a thoughtful analysis of the key structural dynamics and then going though the process of making adjustments to boundary conditions, expanding the dynamics of the model in places, and making simplifications and approximations where possible.
-
Product
Sound Level Meter
-
Maschinenbau Haldenwang GmbH & Co. KG.
Ideal sound level measuring device for almost every acoustical environment.
-
Product
Sound Level Meters
-
Is used for acoustic measurements. It is commonly a hand-held instrument with a microphone.
-
Product
Sound Level Indicators
-
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.
-
Product
Dynamic Signal Analyzer & Data Acquistion
Electroacoustics Toolbox
-
Electroacoustics Toolbox is a modularized, multi-channel dynamic signal analyzer and data acquisition platform for Mac. It brings powerful new tools to the Macintosh platform for multi-channel, audio-band data acquisition and real-time analysis of electrical, acoustical, and electroacoustic signals and systems. It enables precise measurements of acoustic quantities, such as equivalent and time-weighted sound levels, as well as acoustic and electroacoustic systems, such as listening rooms and loudspeakers.
-
Product
Resistivity Imaging & Sounding System
Syscal Junior Switch
-
The Syscal Junior is an all-purpose resistivity imaging and sounding system for environmental applications. The system can be supplied as a standard imaging system capable of recording two measurements simultaneously. The second recording channel significantly improves data acquisition time when the instrument is fitted with internal switching board for 24 (Switch-24) 48 (Switch-48) or 72 (Switch-72) electrodes for Electrical Resistivity Tomography (ERT).
-
Product
Cement Testing Equipment
-
High quality cement is necessary to produce concrete and mortar that meets relevant construction industry specifications. ELE international designs and manufactures a wide range of sample preparation and cement testing equipment which complies with global standards for the assessment of fineness, consistency, setting time, workability, flow, strength, soundness, heat of hydration and chemical composition.
-
Product
PCB IMID01, 100 mV/g, IEPE, 2-Pin, Accelerometer, Industrial Vibration Sensor
784175-01
-
The PCB IMID01 is an industrial Vibration Sensor designed for permanent installations. This sensor helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. The PCB IMID01 features a sensitivity range of 100 mV/g and uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The sensor supports the IMI Industrial Accelerometer Cable as well as the MIL2M-Breakout Cable.
-
Product
Small Device Test Chambers
-
Small Device Test Chambers are used for basic sound level measurement of small products and equipment, pre-compliance testing of small products and equipment and end of line manufacturing test on small products and equipment.
-
Product
Anechoic Chambers
-
Eckel Noise Control Technologies
Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.
-
Product
Pre Amplifier
-
A networked audio device that processes line-level sound and streams music across zones without a built-in power amplifier.
-
Product
Sound and Velocity Data
MIDAS SVX2
-
The MIDAS SVX2 is the standard for the offshore Oil & Gas industry. Recognising the conflict faced by users requiring the superior Sound Velocity data from an SVP, but still needing the Salinity and Density data from a CTD, the Midas SVX2 combines both technologies to give the best of both worlds
-
Product
Audio Analyser
ATB PC Pro
-
The ATB PC Pro Measuring system is a professional Audio Analyser. The Windows program is combined with the computer’s soundcard, the measurement microphone, the Test-Box and the DVD (CD) for the signals forms an exact and extensive measurement system. The applications for the ATB PC Pro are the speaker development, room acoustic optimise, the installation of car sound systems, the setting of Surround reproduction systems and the noise analyser.
-
Product
23KHZ Measurement Microphone
M23
-
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
DC Measurements
-
Standard Windows sound cards do not respond to DC or frequencies lower than a few Hz. (See Why Sound Cards Block DC Signals below for explanation.)There are two general approaches to get true DC response from a standard sound card: Modify the card, or add an external circuit to convert the DC into an AC signal which can be easily measured by an unmodified card.
-
Product
Multiway Life Tester
CH316
-
Measure 16 samples at the same time, evaluate and record the life of each sample. Very flexible: Samples can be added and changed at anytime. The life of each sample is readable at anytime. The switch ON/OFF time is adjustable (Test period is min 1s). Automatically remember the test result when the power is off, and resume the old measurement when power is on. Sound and light alarm when the products were failed.
-
Product
Audio Analysis
-
The MCD AudioAnalyzer is used to test and calibrate analog and digital sound systems, or it can be used to convert analogue audio signals into digital form and vice versa. Also, the conversion of optical to electrical S / PDIF signals and vice versa can be done. The MCD AudioAnalyzer combines software (Toolmonitor MCD AudioAnalyzer) and hardware for the analysis and generation of analog and digital signals in the audio area.
-
Product
Acoustic Calibrators
-
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
Product
Sound, Light & Moisture Tester
-
Make safety compliance checks or perform acoustic analysis using a sound meter. Monitor and optimize light levels, reduce the energy burden of buildings by significantly increasing the efficiency of the lighting system with a light meter. Or check the moisture content of building materials for water damage or harmful mold growth, using a moisture meter.
-
Product
Hydrophone
RESON TC4013
-
The TC4013 offers a usable frequency range of 1Hz to 170kHz and a high sensitivity relative to its size. It further-more provides uniform omnidirectional sensitivities in both horizontal and vertical planes up to high frequencies.The TC4013 is an excellent transducer for making absolute sound measurements and calibrations within a broad frequency range. It can also be applied as an omnidirectional reference projector.The overall characteristics makes TC4013 extremely applicable for laboratory as well as industrial uses.
-
Product
Impulsive Sound Source
BAS006
-
The BAS006 is an innovative device used to create impulsive noise that includes low frequency energy and avoids problems like secondary bounce. These characteristics make it a great choice for quickly measuring reverberation time when the complexity and weight of a speaker and amplifier is not needed.
-
Product
Installation
-
Applied Research and Technolgy
Sound reinforcement solutions for retail, restaurant, classroom, boardroom, worship, and more.
-
Product
Photon Magnetic Resonance
Numis Lite
-
The Numis lite device is a Magnetic Resonance Sounding (MRS) system for the direct detection of shallow groundwater down to 50 m of depth.





























