Showing results: 46 - 60 of 60 items found.

  • Guardian Hipot Analyzer

    19055 - Chroma Systems Solutions, Inc.

    Hipot or dielectric withstand testing instruments manufactured by Chroma are used for conducting electrical safety tests on electrical components and products to make certain they are in compliance with IEC, UL, TUV, CSA, EN and other electrical safety requirements. In addition, these instruments are designed for general product or component testing as well as complex medical safety testing (60601-1) ensuring human safety and product reliability.

  • Flame & Other Plastics Testing

    Educated Design & Development, Inc.

    Plastics are tested to determine their flammability burning characteristics (Flame rating), their ignition potential due to thermal and electrical sources, their resistance to electrical tracking, and other electrical characteristics. The specific test required on a plastic depends on the type of component or end-use product, as well as the environment in which the plastic is used. This test equipment meets most UL, CSA, IEC, EN and other international safety standards.

  • Gas Detection

    Bacharach, Inc.

    Gas detectors designed to help comply with ASHRAE 15 and 34, EN 378, and CSA B52 are to protect someone from entering a mechanical room with refrigerant concentrations that could be harmful to their health. These protection levels are outlined in the safety standards to be about 1000ppm, 8-hour TWA depending on the type of refrigerant being used in the equipment. The alarm set points, location and number of detection points outlined in the safety standards are typically insufficient for finding the more common, smaller leaks that add up to large annual refrigerant emissions, decreased efficiency and overall safety.

  • Explosion-Proof Differential Pressure Switch

    1950G - Dwyer Instruments Inc.

    The Model 1950G Explosion-Proof Switch combines the best features of the popular Dwyer Series 1950 Pressure Switch with the benefit of natural gas compatibility. Units are rain-tight for outdoor installations, and are UL listed for use in Class I, Groups A, B, C, & D; Class II, Groups E, F, & G and Class III atmospheres, ATEX for EExd IIB & Hydrogen T6, and CSA & FM approved for Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G and Class III atmospheres

  • Hipot Tester

    Sentinel - Seaward Electronic Ltd

    The Sentinel series of test instruments has been built to provide a cost effective, yet powerful solution to hipot testing, whether on a production line or in a laboratory environment for compliance testing purposes. With the ability to perform either 5kV AC or 6kV DC dielectric strength tests and up to 500VA AC power output the Sentinel series can aid testing to many international safety standards including IEC, EN, UL and CSA to name but a few.

  • Pressure Transmitters

    Kobold Instruments, Inc.

    Explosion-proof pressure transmitter is approved for use in hazardous locations per CSA Standard 30 and UL Standard 1203 for Class 1, Division 1 and Division 2 hazardous locations. Wetted parts are all 316L Stainless Steel (50 up to 10000 PSIG), 17-4PH (15000 & 20000 PSIG) for compatibility with a variety of media. Wetted materials and construction comply with the NACE MR0175 Standard. The KP46 Series explosion-proof pressure transmitter's fitting and sensing diaphragm are machined out of a single piece of material, so there are no welds, seams or O-ring seals, resulting in excellent long-term performance and stability. The case is factory sealed, making this pressure transmitter very rugged with excellent shock and vibration resistance.

  • Automated Digital Ground Continuity Tester

    Educated Design & Development, Inc.

    1 Button Testing - No setup required, just plug right in!Digital LED display reads out in OhmsAlso performs the Low Current Ground Continuity test, at the same time!Auto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchCustom universal receptacle accepts both 120V and 240V plugs.Zero feature allows you to "zero-out" the test lead impedance.Meets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements.

  • Single, Double Power Cord Tester

    LX-30A+ - Shenzhen Lian Xin Technology Co., Ltd.

    Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards ..·used to test single – ends ,double –ends ,three-ends power supply cords..·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,.·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,

  • Digital Power Meter (High Accuracy Model)

    LS2050 - Lisun Electronics Inc.

    LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.

  • Isolation Power Panels for Healthcare Facilities

    Bender Inc.

    Standards such as NFPA 99 and CSA Z32 require isolated power systems in all areas deemed “wet procedure locations” in healthcare facilities. Isolated power systems offer an invaluable advantage - early detection of ground faults allows for critical systems to remain online in a single fault condition.Bender isolated power panels provide isolated power to electrical systems in operating rooms and other critical care areas. Utilizing the latest in technology, Bender equipment ensures that electrical ground faults are detected and located fast and automatically, in compliance with the latest standards and code requirements.

  • Power Line Purpose Tester

    LX-221A+ - Shenzhen Lian Xin Technology Co., Ltd.

    ·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.

  • Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.

    72-2985 - Tenma

    The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.

  • Automated AC Digital Hipot Tester

    Educated Design & Development, Inc.

    1 button testing - No setup required, just plug right in! Or, make a plug for your cordless product, and plug right in! EASY!Easy to identify PASS / FAIL visible and audible indicationAuto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchSafety Protected Start Switch -- Protects user from shock!Performs the Low Current Ground Continuity test at the same timeMeets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements as well as UL 120Kohm requirementsIncludes ISO/IEC 17025 Accredited Calibration Certificate, accredited by ACLASS (Internationally accepted results... equivalent to A2LA)

  • Flexible Current Sensor Probe

    CTA - Powertek LLC

    The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.

  • Digital Leakage Current Tester

    Educated Design & Development, Inc.

    Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.