Current
See Also: Direct Current, Alternating Current, Resistivity, Flow, Inductance
-
Product
High AC Current Capacitor
LC1/LC2/LC3-AN
-
Induction Heating Processing Equipment, High Current Welding, High Power Resonant Circuits, Motor Controls; Oscillating, Bypass, Coupling circuits, High AC Current applications, High-Frequency AC Filter and Medium Frequency Power applications.
-
Product
Portable Voltage and Current Instruments
-
Each model in our portable test equipment range is designed for accuracy and reliability, providing high performance and ease of use for applications. Products are used in various lab and field applications across industries such as research and development, semiconductor, and process control. For higher range electrical source and measure we have a series of bench multifunction calibrators and multimeters.
-
Product
200 Amp AC Current Adaptor
DL6701
-
The DL6701 is a compact 200A AC current clamp adaptor with voltage output via standard 4 mm connectors. To be connected to a digital multimeter or other voltage measurement device.
-
Product
High Current Probes for EV Battery Packs
High Current Probe
Up to 500Amps - customized connections - battery pack charging.
-
Product
Power Supply and Current Monitor
DC Connect
-
DC Connect enables measurement of current consumption of battery operated and other low voltage devices such as hearing aids
-
Product
Meters for Current & Voltage
EE301-DCM-xx
-
LCD Current Readings:0-80.0 / 40.0 / 20.0. LCD Voltage Readings:0-50.0 / 150.0
-
Product
Auxiliary Current Transformers
-
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Leakage Current Alarm Signaler
MPU-1
-
MPU-1 is dedicated to control (measure) leakage current in AC, low and medium voltage power networks. It is designed to make measurements, which results define network's safety condition for leakage current. The device enables to set limit for maximum safe value of flowing leakage current and for values above this limit visual and sound alarm is activated.
-
Product
High AC Current Capacitors
-
HK Film Capacitors offer a selection of High AC Current Capacitors ( continuous duty) with Temperature up to +105C
-
Product
High Current Connectors
-
C.C.P. Contact Probes Co., LTD.
60% lower extraction force, 80% higher current than other common connectors. The numbers speak for themselves.
-
Product
Bluetooth Recording Current Meter
RCM Blue
-
A self-recording dedicated current meter with Bluetooth for communications and data retrieval - now with the possibility to integrate a pressure sensor!The RCM Blue is a self-recording Current Meter which also measures water temperature in salt or fresh water, and a battery container with battery capacity up to 70Ah. .The Doppler Current Sensor is an upgraded version of the proven SeaGuard ZPulse sensor. The RCM Blue instrument configuration and data retrieval is done via Bluetooth which eliminates the need to open the pressure case for repeated deployments.RCM Blue has now been upgraded with the possibility to integrate a pressure sensor with a 0,01% accuracy. This simplifies your work significantly as you will know exactly where you are in the water column.
-
Product
Current Clamps
-
Due to its variable measuring functions, the digital clamp meter can be operated universally. Useful details, such as the large display, manual or automatic ranging and measurement position lighting, makes operation particularly easy and reliable.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Impulse Current Measuring Shunts
ICMS
-
The Impulse Current Measuring Shunts ICMS are new designed tubular shunt types with best response behavior to match the high performance of the TR-AS digital recorder for comparative current measurements. A 1st partial response time less than 10ns and a settling times less than 20ns show the advantage of these shunts. They show no initial overshoot peak, no oscillations and do not need compensation box to optimize the transient behavior as known from e.g. cage shunts.
-
Product
Time, Current, And Resistance Meter
-
AllWin Instrument Science and Technology Co., Ltd.
1. Time, current and resistance can be displayed simultaneously2. Out put current:5~30A. Ground resistance range: 50~600 mohm
-
Product
Current Transformer
LTTJ
-
Love Controls LTTJ Series Current Transformers allow easy monitoring of the current flowing to your load. This easy to use device provides a 0 to 10 VDC signal into both low and high impedance circuits, and is easily scalable to your needs
-
Product
Flexible Leakage/Line Current Tester
RLM-10+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Low-pass filter equipped, it can be cut the noise which is over 150Hz frequency.●Even Coreless Coil but Least Influence from External Magnetic Field and Residual Current●Superior Flexible CT enables Leakage Current Measurement●Backlight Function useful for measurement in the dark place
-
Product
Burden Set – Current
BSC-102
-
The industry has recognized the actual load (burden) on CTs is lower than the standard ANSI burdens allow. So a new IEEE Specification (IEEE C57.13.6) accommodates that fact by introducing two new burdens and two new accuracy classes. This new specification address “High Accuracy”CTs.
-
Product
Current Preamplifier
1211
-
The model 1211 Current Preamplifier was designed to provide all of the features required of a modern laboratory preamplifier. It measures cur rents with full scale sensitivity ranging from 10 to 10 amperes.
-
Product
Fluxgate 150A Current Sensor
LF03
-
Our LF03 current sensor works with the dynamic Fluxgate measurement technology. It is characterized by its simple, practical design and prevents high temperature drifts. Fluxgate technology uses the phenomenon of magnetic saturation to modulate the measured magnetic field and convert it into an electric field.
-
Product
30A Auto Current & Voltage Tester
7610A
-
Peaceful Thriving Enterprise Co Ltd
*Fast, accurate and safety current measurement from the fuse box.*Feature with large LCD display and mini/ATO fuse probe.*Ideal for diagnostic of vehicle's electrical circuits.*With CE Approval.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-400B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Godzilla High Current Probes, 150 Amp
HC500
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Current Probe For Multimeters
CP 1000
-
The CP 1000 current probe has been designed for use with multimeteres respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Primary & Secondary Current Injection Testing Sets
-
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
Product
Sensor Unit for High Precision Current Sensors
CT9557
-
Hioki pull-through current sensors and clamp on current probes are best-in-class current sensing devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT9555 is 4-channel sensor unit and power adapter for any of the CT686x series, 9709 and CT684x series current sensors and probes that provides waveform and RMS output.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Lightning Current Generator
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
Product
0-600A Current Data Logger
VA601-A2
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function record meter is a new record meter designed for the actual demand of various industrial site, which integr.





























