CC15010X, 10 MHz, 150 A Current Oscilloscope Probe
786849-01
The CC15010X, or Hioki 3274, is a clamp-on current probe that offers a wide DC to 10 MHz bandwidth and 150 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
sbRIO-9208, Non-Enclosed, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780979-01
Non-Enclosed, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The sbRIO‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The sbRIO‑9208 uses a standard D‑SUB connection for use with cables and connector blocks. Non-enclosed modules are designed for OEM applications.
-
product
CC05120X, 120 MHz, 5 Arms Current Oscilloscope Probe
786847-01
The CC05120X, or Hioki CT6701, is a clamp-on current probe that offers a wide DC to 120 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
High Current Probes
*Low internal resistance to minimize arching*PogoPlus bias ball design*High current optimized base material and plating*Higher temperature spring design*Specialized high current tip geometry
-
product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-02
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
product
Current Probes
PMI® introduces the convenience of flexible current probes (Flex CTs)! These 5,000A probes come in 12″, 24″, 36″, and 48″ lengths that allow you to easily surround multiple conductor bundles. They are available in sets of two, three, or four for use with different recorders. The Flex CTs are powered from recorder voltage and DO NOT require a battery pack for operation.
-
product
Current Tester
MIG0624
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.
-
product
Current Meters
Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.
-
product
Current Probes
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
product
Current Sensors
MCx1101 Family
Power architects are continually asked to push the boundaries for system efficiency, response time, small size, and low cost in new power system designs. Most modern designs require current sensors to help implement the complicated control, telemetry, and protection circuitry essential in meeting these difficult design goals.
-
product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-01
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
product
Current Sense Resistors
Panasonic Industrial Devices Sales Company of America
Panasonic offers a wide variety of Thick Film Current Sense Resistors (ERJ-B1, B2, xB, xBW, xCW) in a large range of case sizes and in wide terminal types for high solder joint reliability. The ERJ Series of Current Sense Resistors offers power ratings up to 2W with low ohmic ratings ranging from 5mΩ to 10Ω. Panasonic’s Thick Film Current Sense Resistor portfolio offers a more cost effective option with high reliability. Panasonic has a wide line of case size options ranging from 0402 to 2512 in conventional terminal and 0612 to 1020 for wide terminal.
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
High Current Conditioners
IsoTek’s unique Direct Coupled Design system offers extremely low impedance high current clean power for the hardest of loads.
-
product
Current Clamp Adapter
PeakTech Prüf- und Messtechnik GmbH
It uses a pair of jaw which allow clamping around an electrical conductor to measure the current in a conductor without the need to make physical contact unlike a normal multimeter.
-
product
High Current Probe/DMM
655
Another great tool for all around electrical troubleshooting. The #655 is ideal for all high current applications, especially starting and charging diagnostics. The #655 can measure up to 1000 Amps AC or DC. Unit features built-in degrees F and C temperature readings.
-
product
SparkFun Current Sensor Breakout
INA169
The INA169 is a “high-side current monitor,” which means that you place a resistor (a “shunt resistor”) on the positive power rail and the INA169 measures the voltage drop across that resistor. The INA169 outputs a small current based on the measured voltage drop. If you place a resistor from the output of the INA169 to ground, you can measure the voltage at the output.
-
product
DC Bias Current Source
DU2020/2030/2040
Delta United Instrument Co., Ltd.
Frequency: 10KHz - 200KHz Veracity:3% + 3 digitsTiming: 0.1 - 999 H, settable 3 1/2 bits LCD Display
-
product
Current Source
M151
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
product
Current Transformers
Contrel Elettronica s.r.l. Company
We can supply current transformers (measure transformers, protection transformers and double ratio transformers, with analog output) with the following accuracy classes: 0.1, 0.2s, 0.5s; 1; 3. A wide range of combinations is available in our standard range with specific versions available upon request (other ratios, specific frequency, class or load). They are equipped with sealable terminal covers as standard.
-
product
Leakage Current Tester
2675
Shenzhen Chuangxin Instruments Co., Ltd.
RK2675 series Leakage Current Tester is used to measure the electrical insulation quality and products’ safety performance of the main indicators.
-
product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-80
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Big CT window*AC 1A~1800A*Current measurements of main cable
-
product
Digital Current Integrator
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure DC currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.