Loop Calibrators
Simulate, power and measure closed circuit signals.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
Linear/Angular Measurement Kit
55281B
Mechanical Calibration Kit
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
Mechanical Calibration Kit
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Loop Antennas
-
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
Product
Phase Locked Loop (PLL) Synthesizer & Translation Loop
-
ADI’s industry leading phase locked loop (PLL) synthesizer family features a variety of high performance, low jitter clock generation and distribution devices. The extensive, ever growing family includes over 100 products, optimized for high data rate, low jitter clocking applications. The portfolio features PLLs, PLL/VCOs, and distribution chips, designed for clocking applications where synchronization, clock distribution, and phase noise performance are all vitally important.
-
Product
Quad Op-Amp Loop
QOAL400
-
The QOAL400 module is a precision instrument capable of measuring all common parameters of an Op Amp, including AC as well as DC parameters. The QOAL400 has four completely independent channels, which allow a quad device to be tested in a minimum amount of time. Each channel has a full set of resources to measure all common parameters.
-
Product
Single Loop Controller
1166
-
The 1166 is a powerful, single loop profile controller for complex processes. It offers profiling capability with 4 programs each of 16 free format segments making it a leader in its class.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Calibration
-
We also help to fulfil the recommended calibration cycles of the other measurement instruments within your test system. In case you can not go without the whole system we will find another solution like a change or loan of single devices.We also offer whole test system calibrations on-site as part of our preventive maintenance concept.
-
Product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
-
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Product
Radiating Loops
-
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
Product
Calibration
-
Omega carries a broad selection of calibrators, testers, and accessories for ensuring fast, accurate, and stable readings for all your test applications.
-
Product
RCD Loop Line
-
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
Product
Current Loop Adapter
OP-1C
-
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Calibration Kit YAV90MMU
YAVMMUCK
Mechanical Calibration Kit
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
Product
Calibration
-
To measure a wide range of pressure in an explosive endangered area the range of pressure modules is extended with 8 ATEX compliant models.
-
Product
Loop / PFC Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Product
Calibrators
-
Fluke offers a wide range of pressure calibration tools with precision pressure measurement from 15psi/1 bar to 10,000 psi/690 bar boasting 0.025% full-scale accuracy. Everything from simple test gauges to calibrators with built in electric test pumps. Easy to use, rugged and reliable construction and an industry best 3-year warranty. Fluke means pressure.
-
Product
Loop Meter
MZC-310S
-
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
-
Portable, self-contained, high-intensity acoustic microphone calibration source
-
Product
Calibration
EMC Test Antennas
-
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
Product
Calibrators
-
Electronic Development Labs, Inc.
Your equipment and sensors must function at optimal levels to achieve the results you want—no matter your industry. Engineered by skilled craftsmen to maximum reliability accuracy, EDL calibrators are trusted around the globe—and have been for decades. Your business relies on predictable results that consistently meet quality standards. And EDL has set the standard for calibration.





























