Loop Calibrators
Simulate, power and measure closed circuit signals.
-
Product
Calibration and Repair Services
-
Additel calibrations provide you with high confidence and low uncertainty for your standards. Our accredited calibration laboratory utilizes primary-level piston gauge systems and high-performance controllers to provide services for the entire Additel product line. In addition, our repair technicians which are ready to help, should you have trouble with the Additel units you own.
-
Product
Calibration Hex Step Adapters
-
When performing torque wrench calibration or testing, adapters are often needed, especially with torque wrenches that have open-end heads. Mountz’s calibration hex step adapter features four common sizes, which will increase the productivity of your torque wrench calibration process. This adapter will make testing and calibration simple and efficient.
-
Product
Panel Mount Calibrators
-
Practical Instrument Electronics, Inc.
Now you can panel mount PIE 820 & 830 Multifunction calibrators. As part of a calibration bench, the PIE 820PM or 830PM provide an accurate multifunction calibrator that is easy to use and may be removed for annual calibration. Panel mounting a multifunction calibrator is useful whether you are putting a calibration bench in your instrument shop, require a manual loading station in a control panel or for use as a built-in process simulator.
-
Product
Lamp-Based Calibration Light Sources
-
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.
-
Product
Gas Analyzer Calibration
KANE
-
Partnering with KANE we can now offer you a fast and reliable gas analyser calibration, repair and sales solution. Working closely with KANE we have we can offer you a quick turnaround time usually 6-8 working days or less.
-
Product
Loop Antenna
ZHX7-0.009-200-1486
-
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
Product
4-20 mA Loop Powered Two Wire Oxygen Transmitter
OxyTrans
-
The Edgetech Instruments Model OxyTrans is an easy to use, accurate and economical way to measure Oxygen at trace and % levels. A simple display and one point calibration allows for a quick start of the instrument.
-
Product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
-
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
Product
Calibration Sources
-
Accurately verify the output signals of your pyrometers, thermal imaging systems, heat-flux measurement systems, or spectrographic analysis systems. We offer unique and very precise Mikron® calibration sources. Our blackbodies feature cutting-edge emissivity values, homogenous emission areas, and various different-sized apertures. And fast heat-up times and high temperature stability are guaranteed.
-
Product
Black Body Calibration Sources
-
Nagman Instruments & Electronics Pvt. Ltd
Black body calibration sources by Nagman are used to calibrate infrared temperature devices that are used to measure temperature. Infrared devices can measure extreme temperatures that are very high as well as very low. They allow to measure temperature from a safe distance from the device that is heated or cooled. Calibrating the infrared temperature devices at regular intervals is very important to ensure an accurate and error free measurement. Black body calibration sources allow for an accurate calibration of the temperature devices.
-
Product
Calibration and Repair
-
Traceable vibrometer calibration insures a high level of data quality, critically important for many applications in industry, science and medicine. Polytec service engineers ensure fast and efficient equipment calibration that is traceable to national and international standards, intended to be ISO/IEC 17025 compliant.
-
Product
Calibrators
-
Ensure the accuracy and reliability of your leak and flow testing instruments with our cutting-edge calibrator. Specifically designed for precision calibration, our product stands out in the market for its innovative technology and user-friendly features. Ideal for a wide range of industries, this calibrator is essential for maintaining the integrity of your leak and flow testing equipment. With its robust design and exceptional accuracy, our calibrator is a must-have for professionals seeking to uphold the highest standards in leak and flow measurement. Whether you’re in manufacturing, engineering, or quality control, our calibrator is the perfect tool to ensure your instruments are performing at their best. Discover the difference in precision and reliability with our top-tier calibrator for leak and flow testing instruments.
-
Product
M0710 CALIBRATED LEAK
-
M0710 is the new ForTest® leak –certificated series for verifying leaks during automated tests. The instrument has been patented european wide.
-
Product
Calibration Modules and Kits
-
Keysight Calibration Modules achieve more precise and accurate measurements for your testing needs. Regular calibration is required to ensure your high-performance measurement equipment is operating to its specified performance, and our Calibration Modules and Kits make the calibration of your equipment fast, easy, and accurate.
-
Product
Temperature Calibration Equipment
-
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
Product
N-port Calibrated Measurements
S97551B
-
The S97551B software enables full multiport error correction and measurement capabilities when using multiple USB vector network analyzers
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
Calibration Light Source
CAL2
-
Image Engineering GmbH & Co. KG
The CAL2, based on our 22 channel spectrally tunable iQ-LED source, can be adapted for use in many different areas.
-
Product
Multifunction Field Calibrator & Communicator
MC6-Ex
-
The MC6-Ex is an intrinsically safe field calibrator and communicator. It is ATEX and IECEx certified and can be used in all hazardous zones / divisions. The MC6-Ex includes a field communicator for HART, FOUNDATION Fieldbus and Profibus protocols. Each calibrator is delivered with a traceable, accredited calibration certificate as a standard. t is a documenting, multifunction calibrator and communicator that offers calibration capabilities for pressure, temperature and various electrical signals.
-
Product
Instrumentation Calibration Services
-
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
Electrical Calibration
GF6018A
-
Beijing GFUVE Electronics Co.,Ltd.
The equipment is compliance with national verification regulation: JJG1242005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.
-
Product
Current Loop Adapter
OP-1C
-
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
Portable Multifunction Calibrator
M143
-
Clarke-Hess Communications Research
The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.
-
Product
WAVEPULSER-40IX + WAVEPULSER-SI-STUDIO-NRZ + Adaptors and Calibration Kit
WAVEPULSER-40iX-BUNDLE
-
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables, bundle.
-
Product
Phase Locked Loop with Integrated VCO
-
PLL with integrated VCOs provide local oscillator sources and clock sources for communications (COMMS) , test and measurement (ETM) and aerospace/defense (ADEF) applications. ADI's PLLs with integrated VCO portfolio includes both narrowband and wideband parts, supporting frequencies up to 13.6GHz. Our PLLs with integrated VCO, as well as our full PLL portfolio including integer-N and fractional-N PLLs, feature best-in-class performance for phase noise, jitter, and spurious, and also feature high levels of integration in small form factor packages.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
Calibration Management Software
MET/CAL®
-
MET/CAL software is structured around the flow of instruments through the calibration process and addresses a wide range of test and measurement instrument calibration needs, from the simple to the complex. It is based on the traditional calibration model as its framework—comparing an instrument to a standard of known uncertainty.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.





























