Time Standards
An absolute criterion for measuring time.
See Also: Time, Time Reference, Timers, Time Interval, GPS Time, Time Code, Time Domain, Timing, Hydrogen Masers, Atomic Clocks
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Single Slot 6U, 32-bit Precision Timing Module
VME SyncClock32
-
The VME timing card is a standard board level product of Brandywine Communications. With a single slot 6U, 32 bit precision timing module, the VME card is compatible with VME computers. Precision synchronization to various inputs and convenient timing outputs to external equipment are standard on Brandywine’s VME card.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Time Interval Counter PXI Card
GTX22x0
Interval Counter
The GTX22x0 family of PXI universal time interval counters offer many of the measurement and timing functions of high-end stand-alone frequency counters, including accumulate, auto ratio, frequency, fast frequency (GTX2220 and GTX2230 only), period, ratio, single period, test clock, time interval, time interval delay, totalize, totalize gated, totalize gated once, & pulse width.
-
Product
Standard Voltage 50-Pin D-Type Connector & Cable Accessories
-
The Standard Voltage 50-Pin D-Type connector is used on PXI switching products to provide a medium density connector solution. Connection solutions for modules with High Voltage Rating D-Type connectors are also available.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1R1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Optical Time Domain Reflectometer / OTDR Tester
M-OTDR-802
-
Fuzhou Metricu Technology Co Ltd
Wavelength 1310 / 1550nm, max test range 150KM, Dynamic range 28 / 26dB
-
Product
Standard for Mass Interconnect Performance
TITAN
-
TITAN sets the standard for Mass Interconnect performance, configuration modularity and long term reliability. TITAN has been designed to offer exceptional configuration flexibility for use with any ATE platform and offers unparalleled I/O density coupled with the widest selection of contact types available for Mass Interconnect.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I8-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Real Time X-Ray Imaging
GO-SCAN C-VIEW
-
Go-Scan C-view is a light weight ruggedized real time X-ray imaging system specifically designed for hand-held inspection such, among other, Corrosion Under Insulation (CUI) inspection. It includes a high speed and high resolution CMOS imager and a battery-operated 70kV x-ray tube designed for portable field operation. The video imaging system captures images and displays them on a hand held display in real-time.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-4
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-R
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
Product
Multiple High Resistance Standard
MHS
-
*1 MEGOHM TO 1 TERAOHM*FULLY GUARDED*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGES*TRANSPORTABLEOhm-Labs' new Multiple High Resistance Standard maintains state-of-the-art resistance at levels above 1 megohm.
-
Product
Assured Positioning, Navigation and Timing (A-PNT) Solutions
-
Curtiss-Wright Defense Solutions
Our assured positioning, navigation, and timing (A-PNT) solutions are designed to provide ground vehicles with access to trusted PNT information while operating in conditions with limited, impeded, or denied GPS/GNSS. Cost-effective, simple to configure, and size, weight, and power (SWaP)-optimized, our modules and systems are rapidly deployable on both combat and tactical wheeled vehicle platforms.
-
Product
Timing Board #1
TIO-10 #1
-
Interface board for converting signals on a National Instruments PC-TIO-10 timing board to and from fiber optic signals. Bursts, delayed pulses, and frequencies can be generated on outputs. The input channel can be used to measure frequency or period.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Benchtop Rubidium Frequency Standard
FS725
-
Stanford Research Systems, Inc.
The FS725 integrates a rubidium oscillator (SRS model PRS10), a low-noise AC power supply, and distribution amplifiers in a compact, half-width 2U chassis.
-
Product
Standard Tests
-
The following list contains only the most important standards and does not claim to be complete.EN 60204-1 Electrical equipment of machinesEN 60335-1 Electrical appliances for household and similar useEN 50106 Sampling test, routine tests (in conjunction with EN 60335-1)EN 60598-1 LuminariesEN 60601-1 Medical electrical equipmentEN 60730-1 Automatic electrical controlsEN 61010-1 Measuring, control and laboratory equipmentEN 61439-1 Switch cabinet and switchgearEN 62368-1 Equipment for audio/video, information and communication technologyEN 62841-1 Hand-held electric toolsEN 50191 Erection and operation of stationary and non-stationary electrical test equipmentLVD Low V oltage D irective _
-
Product
Cold-Atom Frequency Standard
-
Rack-mount microwave atomic clock using laser-cooled 87Rb atoms. Production unit target specifications: Allan deviation 2×10-12 @ 1 s, 2×10-14 @ 104 s; flicker floor 1×10-14; absolute accuracy < 1×10-13.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Cable Fault Locator With Time Domain (Intelligent Bridge)
GT00ZD00ZY
-
GAOTek Cable Fault Locator with Time Domain has a reflectometer to locate faults in metallic cables and Intelligent bridge for tesing the broken line
-
Product
Electronic AC Potential Standard
PMT25010
-
Power Measurement Technologies Inc.
Provides the electronic equivalent of a standard potential transformer as typically required for instrumentation potential transformer accuracy testing.
-
Product
Non Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
With over 10,000 Designs, you could customize the product to achieve your spec!
-
Product
NF-Series Standard Models
-
The E-DRIV® NF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.