Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
Low Phase Noise Reference Source
96270A
-
The 96270A RF Reference Source is the simplest, most accurate and cost-effective single instrument for calibrating spectrum analyzers and RF power sensors and more, up to 27 GHz.
-
Product
Power System Analyzer
931A
-
Model 931A, with state-of-the-art PowerDSA™ Digital Signal Analysis, make more measurements, more accurately, and at a lower price than ever before. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard. Model 931A also incorporate full two way serial communication for use in power quality trend monitoring. The model expands usability by including transducer calibration and timer features.
-
Product
Fast Response Flow Controller for Low Flow
HFM-300 / HFC-302
-
The all metal HFM-300/HFC-302 is Teledyne Hastings' metal sealed, fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen by OEM's for its fast response under a wide range of conditions.The HFM-300 / HFC-302 meters and controllers have flow ranges from 0-5 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Fuel Injection Pressure Tester with Quick Couplers
53900
-
Quick couplers provide for fast and easy hook-up. Kit contains adapters to test all GM vehicles with Multi-port and some Throttle Body Injection (TBI). Tests all Chrysler cars with Multi-port turbos and some TBI. Use on Ford older TBI systems not equipped with small Schrader test valve. Includes Large Gage with hang-up hook calibrated from 1-100 PSI (0-7.0 BAR). Supplied with instructions in a vinyl pouch.
-
Product
Smart Factory Inspection System
-
API, recognizing manufacturing industry’s increasing demand for part measurement automation, with a higher degree of accuracy, has developed its Smart Factory Inspection System with true 6 Degrees of Freedom (6DoF) real-time 3D robotic measurement incorporating its proven metrology technology and calibration components.SFIS can be delivered as a customized integrated solution or as a standard production inspection cell.
-
Product
Analog Voltmeters
-
*Dual stick MARK series measure voltage and perform phasing operations from 0V to 75kV*No batteries or calibration required*Determines in-phase or out-of-phase*Determines underground cable faults*Discharges underground cables and other equipment that hold capacitive charges*Versatile for overhead and underground applications
-
Product
TVAC CalPod, 20 GHz
85532B
-
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button, and without removing the DUT or re-connecting standards. Very useful in thermal-vacuum chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the testing to perform a normal re-calibration.
-
Product
Ozone Meters
-
In this section you will find an ozone meter to determine the content of ozone in the air or in the water. The ozone meter is essentially used in environmental technology, but the ozone meter is also used in industrial processes. The ozone meter in water is necessary for water treatment or recycling facilities, such as disinfection processes. The handling of the ozone meter is very simple. The recalibration of the ozone meter can be made by the user at any time. The ozone meter in air requires a more complicated calibration, usually a sensor works for two years with optimal results (little variation) before having to be changed.
-
Product
Hardness Test Blocks, Indenters & Accessories
-
Qualitest offer the largest Hardness Test Block selection in the industry. If you don't see what you're looking for, please call our sales department. All of our Hardness Test Blocks come with Certification. All the blocks are calibrated and accredited to ISO guide 25 and will meet automotive and aerospace standards. The HRC test blocks are calibrated on the new NIST level.
-
Product
True RMS RF Millivoltmeter
3440A
-
The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.
-
Product
Hydrophone
RESON TC 4033
-
The TC4033 provides uniform omnidirectional characteristics within the full frequency range of 1Hz to 140kHz. The Typical sensitivity of -203dB re 1V/µPa and the capacitance of 7nF, ensure an excellent signal to noise ratio, thereby allowing TC4033 to be used with extension cables with only a limited reduction in sensitivity. The TC4033 offers excellent acoustic characteristics and durability, which makes it ideal for a wide range of applications and for calibration purposes.
-
Product
True RMS Multimeter
VA57/VA58
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
VA57 40000 counts Extra-safety intelligent multimeter VA58 Extra-safety process calibration multimeter.
-
Product
ICP Microphone System
378A14
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Meter Test System
MTS-100
-
Kongter Test & Measurement Co., Limited
This Meter Test System features state-of-art designing with high accuracy. It is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 120A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Frequency Meter, 3.7 to 12.5 GHz
537A
Frequency Counter
The Keysight 537A direct-reading frequency meter measures frequencies from 3.7 to 12.5 GHz quickly and accurately. Its long scale length and numerous calibration marks provide high resolution. This is particularly useful when measuring frequency differences or small frequency changes. Frequency is read directly in GHz so interpolation or charts are not required.
-
Product
Automatic Calibration Module
ACM4509
-
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Thermometer Hygrometer
H3531-4
-
Sensor H3531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
Technology of Global Market Leader
AeroFIS
-
Aerodata is the only manufacturer of Flight Inspection Systems with an in-house aircraft integration capability and can therefore assume full responsibility for the integrated performance of the aircraft and flight inspection equipment. As a European manufacturer with international recognition, we can provide unique capabilities for the supply of advanced flight calibration equipment with special consideration of compliance with both European (EASA) and US (FAA) regulations, equipment compatibility with neighboring countries, and highest levels of product support.
-
Product
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle
865682-01
-
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
Product
ORP/Redox & Temperature Pen
Ultrapen™ PT3
-
This instrument is designed to be extremely accurate, fast, and simple to use in diverse water quality applications. Advanced features include highly stable microprocessor-based circuitry; automatic temperature compensation from 15ºC to 30ºC while in calibration mode; user-intuitive design; and waterproof housing. A true one-handed instrument, the PT3 is easy to calibrate and easy to use. To take a measurement, you simply push a button then dip the PT3 in solution. Results display in seconds.
-
Product
Fuel Injection Pressure Tester with 2 Gages
33950
-
Test gasoline fuel pump pressure on most domestic and imported fuel injection equipped vehicles.Kit contains adapters to test all GM vehicles with Multi-port and some Throttle Body Injection (TBI). Test all Chrysler cars with Multi-port turbos and some TBI.Use on most Ford TBI systems equipped with or without small Schrader test valve.Test all Ford vehicles with multi-port fuel injection systems.Includes two gages: Large Gage with hang-up hook calibrated from 1-100 PSI (0-7.0 BAR) and Small Gage for lower pressure requirement 0-50 PSI (0-3.5 BAR).
-
Product
Compact Vibration Generator
-
The compact vibration generator is used for calibration of a vibrometer, measurement of mechanical impedance, excitation source for modal analysis and reliability test of a small light specimen. In particular, EMIC uses the world's first ceramic armature for the 512-D and 513-D vibration generator,making it possible to excite up to high frequency of 30 kHz (513-D can excite up to 24 kHz).
-
Product
Shuttle Bus PMC Intelligent Interface Card
IIB-SB-PMC
-
The Shuttle Bus PMC is an intelligent interface card providing all Launch Data Bus, Ground Data Bus, Multiplex De-Multiplex Multiple Remote Terminal, and Ground Data Bus (GDB)capability to the Shuttle Bus, together with a Pulse Code Modulation Mode. This card provides all features and functions required in a PMC platform, withSimplex & Half-Duplex modes provided. Specific operational modes provided include for LDB_BCT, LDB_MRT, GDB_BCT, GDB_MRT, BUS_MON, MDM_MRT, Primitive and Calibration modes.
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
Product
Novo-Gloss Trio Glossmeter 20/60/85
-
20/60/85 glossmeter for measuring matt to mirror finishes. Complies to ISO 2813 and ASTM D523. Supplied with 2 year warranty, NIST traceable calibration tile
-
Product
Headlight Testers
-
Devices for the calibration of car lights.We work every day with passion to offer you efficiency and reliability.Each component is assembled by our technicians with the utmost care and expertise.





























