Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
60 GHz Noise Figure Test Set
-
The Noisecom 60 GHz Noise Figure test set has 4 separate systems designed to perform Y-factor noise figure measurements using a high performance Spectrum Analyzer or a dedicated receiver. Each system contains a highly stable V-band noise source, isolator(s), optional waveguide to coaxial transitions and an optional pre-amplifier for use with a spectrum analyzer. The two standard calibration tables have ENR data points at 1 GHz intervals.* System ENR is measured before the DUT connector and at the final output stage allowing for pre-test calibration of the system.
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
Standard Resistors for Temperature Measurement
-
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
Product
Product Testing Services
-
Reliable products satisfy customers. DELTA offers mechanical and climatic, EMC, microelectronics, safety and information technology testing services. In addition, DELTA provides testing and calibration services in the fields of acoustics and lightning.
-
Product
Fast Response Flow Controller for Medium Flow
HFM-301 / HFC-303
-
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
Product
Step Attenuator
RSC
-
The R&S®RSC is a switchable, mechanical step attenuator. It is available in various models with up to 6 GHz and 18 GHz, and can also control compact external units up to 40 GHz and 67 GHz. The base units provide a GUI for various settings, calibration and configuration of external modules. All models have RF connectors on the front panel or rear panel for rack installation
-
Product
Ozone Meters
-
In this section you will find an ozone meter to determine the content of ozone in the air or in the water. The ozone meter is essentially used in environmental technology, but the ozone meter is also used in industrial processes. The ozone meter in water is necessary for water treatment or recycling facilities, such as disinfection processes. The handling of the ozone meter is very simple. The recalibration of the ozone meter can be made by the user at any time. The ozone meter in air requires a more complicated calibration, usually a sensor works for two years with optimal results (little variation) before having to be changed.
-
Product
Image Analysis & Stage Micrometers
-
The APPLIED IMAGE series of Image Analysis and Stage micrometers are ideally suited for calibrating optical, imaging, video, and reticle-based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Both types of micrometers come with NIST traceable calibration standards and are available on multiples substrates to perfectly fit your needs. The experience APPLIED IMAGE has in manufacturing precision imaged optical components makes us the trusted source for standards for magnification system microscopy and vision applications. Should you need to alter feature patterns, size, or substrate, fill out our Custom Optical Components and Standards form to start the conversation.
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
-
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
Product
Decade Box, Calibrated W/Data, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL D
-
The 72-7270 CAL D from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
IR Linear and 2D Sensor Array Modules
-
Excelitas offers Linear and 2D IR Imager Arrays based upon our Thermopile Technology. All Arrays are provided as plug-and-play Modules featuring a sensing chip, robust metal housing with focusing lens, a PCB with microprocessor for calibration and bus interface and a quick connector for streamlined plug-and-play integration. We offer 8-pixel, 16-pixel and 32-pixel Linear IR Imager Array Modules for field-proven effectiveness in scanning presence detection, non-contact temperature measurement, smart-home products, and office electronics. Custom solutions also available upon request.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Distribution Amplifiers
-
The Quartzlock range of distribution amplifiers are intended for use when multiple outputs from a single frequency standard/generator are required. This may be encountered in engineering labs, national standards labs, research and development, calibration labs and production. This is vital for the distribution of signals from other precision frequency standards like Hydrogen Masers, Cesium oscillators. For a technical discussion about distribution amplifiers go here or select a product range below.
-
Product
Model AM-IIIB: Paper Moisture Meter
AM-31B3
-
Portable digital paper moisture meter to measure single sheets. Permits instant and non-destructive moisture detection measurement on all types of paper and paperboard. Pre-programmed with 11 different Calibration Curved with option to select a field. Fast and accurate. Uses Radio Frequency to minimize effects of pH and temperature variations
-
Product
PCI Strain Gauge Simulator Card, 2-Channel, 2k
50-265-302
-
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
Stat Guardian Plus Constant Monitor
-
ests person, wriststrap, and matLED and buzzerNIST calibration includedWorks with single wire capacitance wriststrapsCE markCan be calibrated110v AC suppliedProduct conforms to the ESD S.20.20 spec standardsGround dock included
-
Product
Calibration Kit
WR-12
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
Beacon Transmitters for Radio Amateurs
-
Is a radio beacon, whose purpose is the investigation of the propagation of radio signals. Most radio propagation beacons use amateur radio frequencies. They can be found on LF, MF, HF, VHF, UHF, and microwave frequencies. Microwave beacons are also used as signal sources to test and calibrate antennas and receivers
-
Product
Chilled Mirror Hygrometer
DewMaster
-
One, two or three stage sensors available - integral or remote from controller.NIST traceable calibration certificate.Depression range choice of either 45, 65 or 95°C . (one, two or three-stage cooling)Automatic Balance Control (ABC)
-
Product
Voltage Dataloggers
-
Transcat is your premier provider of voltage dataloggers. We carry an extensive inventory of test & measurement equipment, with over 3000 products available for same-day shipping. For many instruments, new instrument calibration is also available, ensuring that your product is tested and ready for use as soon as you get it.
-
Product
4-20mA Current Loop D/A Converters
-
ADI integrated solutions combine both the D/A converter and driver in one chip to provide the required output directly from the digital domain. Analog Devices’ portfolio of leading industrial D/A converters and drivers provides a range of programmable output ranges from standard 4 mA to 20 mA for current loop communication to ±10 V for actuator control. ADI industrial converters offer considerable control functionality and advanced on-chip diagnostics to maximize system uptime, as well as eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
Product
Cross Voltage Testers
-
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
Product
Dead Weight Tester
-
Nagman Instruments & Electronics Pvt. Ltd
Dead Weight Tester are a simple, low cost instrument to calibrate pressure devices. It basically works on the pressure balance principle with calibrated weights used to apply pressure to an area. When the pressure balance reaches zero, the pressure device under test is considered calibrated. Nagman’s range of dead weight tester are known for their best quality, industrial grade build with quick stabilization and ease to use.
-
Product
Weighing Instruments
-
ZhangZhou Weihua Electronic co.,ltd
are devices to measure weight or calculate mass. Spring balances or spring scales measure force (weight) by balancing the weight due to gravity against the force on a spring, whereas a balance or pair of scales using a balance beam compares masses by balancing the weight due to the mass of an object against the weight of a known mass or masses. Either type can be calibrated to read in units of force (weight) such as newtons, or in units of mass such as kilograms, but the balance or pair of scales using a traditional balance beam to compare masses will read correctly for mass even if moved to a place with a different (non-zero) gravitational field strength (but would then not read correctly if calibrated in units of force), while the spring balance would read correctly in force in a different gravitational field strength (but would not read correctly if calibrated in units of mass).
-
Product
Battery Cell Simulator
BCS-LABCAR
-
The ETAS Battery Cell Simulator (BCS-LABCAR) is a Hardware-in-the-Loop system which specifically targets the signal-level test, validation, and calibration of battery management systems (BMSs). The BCS-LABCAR is a high-precision Battery Cell Simulator that emulates the behavior of individual battery cells and packs across a wide range of challenging operating conditions, e.g. cell balancing over-charging, deep discharging, or pulse operation. The system is highly modular and thus scalable to emulate battery packs from a single cell all the way up to 200 cells.
-
Product
SSG Series Strain Gauge Extensometers
-
Shimadzu’s SSG series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards, including those for plastics and metallic materials These lightweight, precision extensometers feature a wide elongation measurement range, while retaining the flexibility to measure using small gauge lengths, and support both rod and flat plate shaped specimens. Consisting of an elongation sensor and amplifier, this extensometer is suitable for use with metals and hard plastic materials, and is fastened securely to specimens with screws. Calibration using an extensometer calibrator allows the extensometer to meet JIS and ISO Class 0.5 and ASTM Class C standards for higher accuracy.
-
Product
Measurement and Analytics Solutions
-
Based on our OTP² system platform, we were able to implement a family of scalable test systems which is based on a common systems architecture, e. g. for products in the area of chemical analytics measurement. We not only implemented a universal, extremely comprehensive test system, but also a series of compact systems for benchtop placement which are fully compatible with the larger, universal system. Our specialized self-test adapters and test software enable fast verification of the test systems as well as partly automated calibration by the customer.Our systems are also used in electrical measurement applications, e. g. for calibrating analog input assemblies for PLC technology. For this purpose, specialized calibrators are integrated into the system; they provide traceable calibration of the relevant stimulus signals.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
-
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.