Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Humidity Calibration Cell
Humidity calibration involves checking the accuracy of and making the proper adjustment to sensors that measure moisture content in the air.
-
product
Optical Signal Test Set
OST
The Optical Signal Test Set (OSTS) combines a state of the art optical power meter, a variable attenuator, and a high stability laser source. The unit is able to measure optical signals below -100dBm with 0.001dB resolution at a fraction of the size, power, and cost of competing solutions. Other features include data logging, programmable filtering, and auto calibration. Its small shielded ruggedized package, USB/power interface, and low cost make this unit perfect for lab use or for integration into larger systems.
-
product
E-Series Average Power Sensor
E9301B
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formats Low SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
CM2302 Digital Temperature & Humidity Sensor
28059
Do you need convenient environmental input for your microcontroller projects? The CM02302 supplies both temperature and relative humidity data when queried. This sensor is factory pre-calibrated, so you won’t need to calibrate it before using it in your project.
-
product
Current Source
M151
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
product
12-bit, 200KHz, 8SE/4DIFF Isolated AI, 4 12-bit AO, 8 Optically Isolated Dig. I/O, 24V, 24 TTL I/O
APCI-3110-8
The APCI-3110 is a 12-bit multifunction board for 3.3 V and 5 V PCI systems, with optical isolation up to 1000 V and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.Furthermore, the board has a PCI DMA, 2 watchdogs, 4 digital inputs and 4 digital outputs. Sensors, which allow to supply current signals instead of voltage signals, also can be acquired with the APCI-3110, as this board offers up to 16 current inputs. The board is protected against overvoltage and input filter and it is protected against high frequency emmission. With the free calibration tool you can do the fine adjustment on-site.
-
product
3 Wire (Analogue) Earth Resistance Tester
4105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
Antennas
Emissions
Laplace offers a Comprehensive range of antennas. These cover all the radiated emissions and immunity test requirements. All antennas are supplied with calibration and AF data.
-
product
Airborne Gravimeter
GT-2A
The very large dynamic range provides high precision data even in turbulent flying conditions; data is acquired through short periods of saturation in extreme turbulence by the automatic application of a reduced order Kalman filter, enabling platform misalignment to be computed and hence controlled; the automatic calibration program computes accelerometer scale factors and errors in perpendicularity between the accelerometer sensitive axis and the platform surface. The GT-2A installation in a fixed wing aircraft is shown in Fig 1 (courtesy of Excalibur).
-
product
Portable Protection Test Set and Calibrator
CMC 430
The CMC 430 is the preferred choice for test engineers in cases where excellent transportability is needed and three currents up to 12.5 A or six voltage outputs are sufficient. Its low weight of just 8.7 kg / 19.2 lbs, and robust design with its edge protection predisposes the device to every outdoor and indoor use.
-
product
Calibration - Certification - Repair Services
Acculab Measurement Standards, Inc.
Whatever your Test & Measurement Equipment service needs, ACCULAB has a cost-effective solution! From complete calibration, certification and repair capability at our 6200-sq.ft. state-of-the-art laboratory, to the convenience of on-site calibration at your facility, ACCULAB can tailor a program to meet your individual requirements.
-
product
Calibration Wheel
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Calibration wheel is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
product
Coaxial Termination, DC to 26.5 GHz
909D
The Keysight 909D is a precision, low-reflection dc to 26.5 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard.
-
product
Waveguide Power Sensor
Make accurate and reliable measurements in the 50 to 110 GHz frequency range. Keysight's waveguide power sensors offer best SWR, high reliability and low loss, and come with a 50 MHz calibration port to reduce measurement uncertainties.
-
product
Calibration Hand Pumps
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
High Precision Angular Positioning, Calibration and Geometry INspection
LabStandard AIR
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.The LabStandardAIR has been designed as a “Contact Free” system and eliminates features, which may detract from achieving the optimum rotational performance. The rotating elements are supported on super high precision, air lubricated, hydrostaticbearings and are not subject to disturbances associated with gear drives.
-
product
Converter Of Electrical Quantities
The converters are intended for the conversion of electrical quantities DC signal which is either in form of the DC voltage, or the DC forced current. They can be used in connection with indicating pointer instruments, calibrated in units of the measured quantity, or with a recorder or, eventually with a digital instrument.
-
product
Dry Block Calibrator
We offer temperature dry blocks in different models; we offer easily portable and fast temperature blocks for field use and high accuracy temperature blocks for laboratory use.
-
product
Calibration Standards
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
product
Calibration Services
Mors Smitt has a professional calibration center. All electrical measurement equipment can be calibrated (for example; multimeters, current clamps, temperature meters, installation testers, power meters, safety testers, etc.).
-
product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
Network Simulator
SWAT WDS
Alethea Communications Technologies Pvt Ltd
Alethea’s SWAT WDS Network Simulator emulates the whole Customer Premises side with one box generating up to 32 CPEs with 4 ~ 8 ethernet clients behind each CPE. This setup which mirrors actual field deployment allows transmission points to be checked in detail as soon as the access point is setup. The solution gives a calibrated measure of the User Experience expected over the deployed system.
-
product
Signal Optimizer Software
A unified software package for calibration, signal creation and analysis.
-
product
C Series Voltage Output Module
The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Dipole Antenna
AD-100
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
product
Imaging Photometers
Westboro Photonics offers an intelligent selection of imaging photometers. With a wide range of resolutions, an assortment of lenses, flexible software, and cooled systems, our products are unmatched in the marketplace. We provide three series of photometers to satisfy almost any 2D luminance-based measurement need. Applications including Graphics Testing, Beam Pattern Distribution, Flat Panel Displays and Avionics Panel Balancing are handled with ease, thanks to our robust design, extensive calibrations, and flexible, intuitive analysis software.
-
product
Analytical Reference Materials & Standards
Agilent, now with former Ultra Scientific, offers a comprehensive portfolio of analytical standards, reference materials and certified reference materials for environmental, food safety, elemental analysis, instrument calibration, tuning mixes, and more.Reference materials and certified reference materials are substances that are tested to be homogenous and have fixed values of its concentrations. These standards are a critical component of your application workflow - from sample prep, instruments, columns, supplies, and services. The success of your analysis depends upon the quality of your reference material. All Agilent standard reference materials have been manufactured to the highest quality in an ISO 9001, ISO 17025 and 17034 accredited facilities to ensure the accuracy of your analyses.If you need a custom reference material, partner with us to design and develop a custom standard to your specifications.
-
product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.





























