Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
Frequency Meter, 3.7 to 12.5 GHz
537A
-
The Keysight 537A direct-reading frequency meter measures frequencies from 3.7 to 12.5 GHz quickly and accurately. Its long scale length and numerous calibration marks provide high resolution. This is particularly useful when measuring frequency differences or small frequency changes. Frequency is read directly in GHz so interpolation or charts are not required.
-
Product
PC/104 8-Channel Smart Sensor Interface
518
-
Measures thermocouples, RTDs, strain gages, thermistors, 4-20 mA, voltage and resistance 8 high-accuracy differential input channels Integral sensor excitation Exclusive pulsed excitation minimizes sensor self-heating Configurable sensor type per channel Fully electronic calibration Low power
-
Product
PCI Strain Gauge Simulator Card, 2-Channel, 1k
50-265-202
-
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
GRIDSCAN 5000
Hydrogen Series
-
The H2scan GRIDSCAN 5000 Hydrogen Sensor pairs a high performance ASIC to H2scan’s field-proven solid-state hydrogen sensor. This stand-alone sensor system has been designed to provide precision hydrogen measurement, at a lower cost for the high-volume OEM or utilities. No calibrations or maintenance is needed for up to 10 years, and the GRIDSCAN 5000 is the lowest cost by thousands to any other available hydrogen DGA system. H2scan is the only company in the industry that can state retail sales of over 15,000 sensor systems worldwide with no after sale calibrations performed since 2012.
-
Product
ReCalibration and Post Calibration Software
SI58
-
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
Product
Gas Monitor
ULTIMA® X5000
-
The ULTIMA® X5000 Gas Monitor is the future of gas detection for oxygen, toxic and combustible gases. MSA XCell® gas sensors with TruCal® technology offer calibration cycles up to 24 months (local calibration respected).
-
Product
Reference Temperature Sensors
-
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
Product
Reference Pressure Transducers
-
These Baratron® capacitance manometers offer our highest level of presure measurement accuracy making them ideal for calibration transfer standards.
-
Product
Digital Step Attenuators
-
Ranatec’s digital step attenuators covers all mobile frequency bands and gives a calibrated attenuation range of more than 90 dB in steps of 0.25 dB. All Ranatec digital attenuators are built as modules and offers both serial and parallel control logic.
-
Product
Handheld UV Intensity/Power Meter
Model 308
-
Dependable and repeatable, The OAI Model 308 UV Intensity/Power Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data logging of intensity mode, time, wave length, serial number and calibration due date.
-
Product
AC Measurement Standard
5790B
-
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
Product
Economic Type Resistance Indicator
CS1-RS
-
CS1-RS economic type Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm(2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
Product
Temperature Sensors
TT420
-
Features• 2-wire, loop-powered 4-20mA analog output• Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner• Compatible with PLCs, meters, and data acquisition systems• No user calibration• TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap• TT420F mounts onto any flat surface• UL listed, Intrinsically Safe (IS)• Class I, (C, D) and Class II, (E, F, G)
-
Product
FTIR Gas Analysers
-
Protea’s range of Fourier Transform Infrared (FTIR) Gas Analysers allows for the measurement of nearly any gas with one instrument. A FTIR gas analyser collects a full infrared spectrum continuously, allowing for hundreds of gases to be detected and measured at once. Changes are only needed to software calibration files to measure new gases.
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
Battery Cell Simulator
BCS-LABCAR
-
The ETAS Battery Cell Simulator (BCS-LABCAR) is a Hardware-in-the-Loop system which specifically targets the signal-level test, validation, and calibration of battery management systems (BMSs). The BCS-LABCAR is a high-precision Battery Cell Simulator that emulates the behavior of individual battery cells and packs across a wide range of challenging operating conditions, e.g. cell balancing over-charging, deep discharging, or pulse operation. The system is highly modular and thus scalable to emulate battery packs from a single cell all the way up to 200 cells.
-
Product
10 MHz To 54 GHz LAN Thermal Vacuum Compliance Power Sensor
L2066XT
-
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
Product
High Voltage Meter
DU-3900
-
Delta United Instrument Co., Ltd.
The DU-3900 is a digital voltmeter that can measure high voltages up to a 10kV AC and DC at high accuracy. Its high input impedance (1000M) makes it suitable for measurement of high impedance voltage circuits. Since it has a high accuracy despite its small size and light weight, it can also beeasily used as a portable calibrator.
-
Product
EcoTestr™ pH 2+ Pocket pH Meter
-
This new addition to the Oakton EcoTestr product line features updates to make measuring water quality easier and faster. The display is larger with a better viewing angle, has indicators for battery life, readiness, and calibration, and shows both the parameter and temperature readings at the same time. To enhance field use, the cap was redesigned to be leakproof and can be attached to the top of the meter when not being used—no more lost caps! The cap features a fill line, so you know how much sample you need for an accurate reading when using the cap as a sample cup. It is also wider, providing a base to keep the meter upright for hands-free measurements. The keypad now has a fourth key to simplify menu navigation while keeping convenient one-touch calibration. The new housing is compatible with lanyards to prevent losing or dropping, but is still waterproof and floats just in case.
-
Product
Silicon Diodes
DT-670 Series
-
DT-670 Series silicon diodes offer better accuracy over a wider temperature range than any previously marketed silicon diodes. Conforming to the Curve DT-670 standard voltage versus temperature response curve, sensors within the DT-670 series are interchangeable and, for many applications, do not require individual calibration. DT-670 sensors in the SD package are available in four tolerance bands—three for general cryogenic use across the 1.4 K to 500 K temperature range and one that offers superior accuracy for applications from 30 K to room temperature. DT-670 sensors also come in a seventh tolerance band, B and E, which are available only as bare die. For applications requiring greater accuracy, DT-670-SD diodes are available with calibration across the full 1.4 K to 500 K temperature range.
-
Product
Coaxial Termination, DC to 50 GHz
85138B
-
The Keysight 85138B is a precision, low-reflection dc to 50 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard. The Keysight 85138B has a 2.4 mm female connector.
-
Product
Measuring Receivers
-
Calibration and performance check of signal generators and attenuators
-
Product
Infrared Thermometer Calibration
-
Nagman Instruments & Electronics Pvt. Ltd
Nagman’s Infrared thermometers Calibration Instrument can be used for hassle free temperature measurements as they work on non- contact principles. You can stay at a safe distance from the temperature source and still find accurate readings by pointing IR thermometer at the source. These also have a digital display of the temperature readings and hence, any and all manual errors can be avoided.
-
Product
Continuous Time Interval Analyzers
GT668PXI-15
-
GuideTech’s GT668PXI-15 PXI 3U form factor, meets industrial standard chassis with an expandable platform, achieving optimal test system at low cost. High accuracy 50MHz time base with NIST traceable calibration.
-
Product
In-Line Speedometer Calibrator Module
-
Hypertech’s In-line Speedometer Calibrator Module is an in-line module to correct the speedometer and odometer for non-stock tire sizes and/or rear gear ratios. This module is perfect for vehicles with computers that don’t allow for tire size and/or rear gear ratio correction or re-calibrate for tire sizes and/or rear gear ratios outside the range of programmers.
-
Product
Immunochromato-Readers
-
The C10066-10 Immunochromato-Reader makes rapid, high sensitivity, quantitative measurements of color intensities for red/blue-based immunochromatographic reagents. Since measurement data is saved as a CSV file, it can be analyzed on commercially available spreadsheet software, and calibration curve and time-course graphs then easily drawn. The C10066-10 Immunochromato-Reader is an optimal tool for R&D work as well as quality control of immunochromatography reagent kits.
-
Product
JETCAL® Engine Analyze
BH112JD-80
-
An operator can program the Data Acquisition Unit (DAU) withthe appropriate frequency and pressure calibrations required totest 10 selectable engine types. Test results may then be printedimmediately using the printer installed in the unit.
-
Product
E-Series Average Power Sensor
E9300B
-
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters