Rubidium Frequency Standards
See Also: Rubidium Standards
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25A-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Serial Page EEPROM
-
Serial Page EEPROM is a high-density, page-erasable SPI EEPROM memory that combines flexibility, performance, and ultra-low power. The Serial Page EEPROM with proprietary NVM cell technology delivers fast erase/write performance with high cycling endurance and robust retention. The new architecture allows fast wake up and byte flexibility, as well as block management and fast quad output, while keeping current surge and energy budget at very low levels.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1000
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations.
-
Product
The Industry Standard for Automated Network Protocol Validation
IxANVL
-
Keysight Network Applications and Security
With Ixia’s IxANVL (automated network validation library), you can quickly and effortlessly access a vast array of protocol libraries and utilities to validate protocol compliance and interoperability. Easy to use thanks to an enhanced GUI and flexible test-automation capabilities, IxANVL delivers a number of key advantages. By emulating large, multinode networks, it not only reduces costs—it also leads to more efficient testing and faster product-release times. And extensive and thorough automated testing increases your confidence in product quality.
-
Product
Reflectance Standards
-
Diffuse reflectance calibration standards in white or different grey levels. Traceable calibration for the wavelength range from 250 nm to 2450 nm.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1H-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Nanoscale Microscopy Standards
-
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I15-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-9
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Low Frequency Active Antenna And Amplifier
Type NLF-2
-
A Hot, Active, Noise Reducing Antenna System that will sit on your desk and copy 2200, 1700, and 600 through 160 Meter Experimental and Amateur Radio Signals!
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Time & Frequency Distribution Amplifiers
-
Brandywine offers a wide range of high quality, state of the art signal timing distribution amplifiers, all with very low phase noise. These precision timing signal distribution amplifiers offer a variety of time and frequency signals and interface formats including IRIG A, IRIG B, Have Quick, 1PPS, as well as low phase noise reference frequencies. All of our distribution amplifiers feature dual inputs with automatic failover and multiple independently buffered outputs.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25J-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
1231a Very High Frequency Distribution
-
Precise Time and Frequency, Inc.
The ptf 1230A(1U)/1231A(2U) GPS L-Band RF Distribution amplifiers provide high performance GPS signal references for laboratory or systems use. In most applications the low noise and signal gain capability of the units will provide userswith a robust GPS signal source for lab or system requirements.The ptf 1230A/1231A uses individually buffered output stages and insures maximum isolation between the individual outputs. The ptf 1231A offers 12 outputs. Options are available for a 2U/3.5” version (ptf 1230A) with 24 outputs.Isolation from output to output is >-40 dB. The input also offers DCV for biasing an active antenna.
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Wireless Test Standards Software
test
Generate and analyze signals for cellular and connectivity standards with NI PXI RF instrumentationPerform advanced automated test with the easy-to-use NI-RFmx software APISave on all NI RF wireless test software under a single license
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1J
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
8 Channel 1GHz High Frequency for SBDT Relay Module
DP-cPCI-4158
-
DP-cPCI-4158 is a 8 channel high frequency SPDT relay module. It provides for 1000V DC isolation between channels. This module is constructed using SPDT relays.
-
Product
FREQUENCY DISPLAY UNIT
TYPE NFD-1
-
The National RF Type NFD-1 Frequency Display Unit was designed for use with vintage and classic communications equipment, to display the received or transmitted radio frequency. The unit incorporates an internal processor that allows the intermediate frequency (IF) to be counted out by the frequency counter. The resultant display is the actual frequency that the equipment is receiving or operating at.
-
Product
Standard Loggers
-
Our standard loggers can measure up to 13 parameters. Numerous configuration options allow for maximum customization for your measurement needs. In addition to our conductivity, temperature and depth sensors, many others, including third-party sensors, can be used with our recorders. Measure salinity. Measure tide and waves. Altitude & Attitude Logger.
-
Product
Multiple High Resistance Standard
MHS
-
*1 MEGOHM TO 1 TERAOHM*FULLY GUARDED*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGES*TRANSPORTABLEOhm-Labs' new Multiple High Resistance Standard maintains state-of-the-art resistance at levels above 1 megohm.
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02