Showing results: 91 - 105 of 322 items found.
-
DRK209 -
Shandong Drick Instruments Co., Ltd.
DRK209 is applicable to test plasticity property when the specimen bears 49N pressure. The meter is used to test plastic value and restoration value of raw rubber, plastic rubber and rubber.
-
1500 -
Elcometer Limited
The Elcometer 1500 Cylindrical Mandrel on a stand is a simple instrument for determining the elasticity, adhesion and cracking of dry paint on flat specimens, consisting of mandrel support which also serves as a test stand.
-
CX-J16 -
Shenzhen Chuangxin Instruments Co., Ltd.
This test is conforms to IEC60558-1 Fig6 and IEC60065 Fig14--16.The test shall be performed by fixing the specimens of thin sheets on a mandrel made of nickel plated steel or brass with smooth surface finish.
-
Shimadzu Corp.
Pneumatic non-shift wedge grips have an open-front design and use one-touch chucking by foot operation to provide simple specimen mounting. These grips are suitable for tensile testing materials such as plastics and metals.
-
TRViewX -
Shimadzu Corp.
TRViewX is an advanced non-contact extensometer that offers high-measurement accuracy, is capable of measuring width changes, and is applicable to a wide variety of materials testing applications. In particular, due to the non-contact design, TRViewX is perfect for measuring films, foils, and other thin or narrow materials without affecting the specimen during testing. Furthermore, TRViewX can be used to measure displacements during atmosphere-controlled testing in a thermostatic chamber. TRViewX provides high-accuracy measurements in accordance with ISO 9513 Class 0.5 and JIS B 7741 Class 0.5 for elongation measurements and ISO 9513 Class 1 and JIS B 7741 Class 1 for width measurements. It is compliant with plastic tensile testing standards, including ISO 527, JIS K7161, and ASTM D638, even supporting 75 mm gauge length specimens (type A1 specimens) specified in ISO 527 and JIS K 7161.
-
MT-4 -
Physitemp Instruments
Fast-response 29 gauge needle probe with blunt tip, (needle length is 1cm) for instant readings. Good for instant skin temperature and surface temperatures, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Copper Mountain Technologies
Epsilometer solution for measuring the dielectric properties of materials measures dielectric substrate materials at frequencies from 3 MHz up to 6 GHz and can accommodate sheet specimens 0.3 to 3 mm thick.
-
SG-P03E -
Jinge Testing Machine Co.,Ltd
Use a cutting tool to pierce the specimen between the cleats at three points along the line of maximum bending stress. By the specified speed and times of 90°bending action to inspect the cuts’ growth with a measuring.
-
Model 3475 -
Jinan Testing Equipment IE Corporation
A miniature extensometer designed for general purpose transverse or diametral strain measurements on small or thin specimens. May be used simultaneously with the Model 3442 miniature axial extensometers or the Model 3542 axial extensometers.
-
Qualitest International Inc.
Originally designed to precrack specimens for fracture mechanics, the current versions offer much more possibilities due to a modular concept:*Bending up to 160 Nm*Tension/Compression up to 8 kN*Torsion
-
Denshijiki Industry Co., Ltd.
Using the "leakage magnetic flux" phenomenon generated from the scratches, the magnetic powder (or fluorescent magnetic powder) of the ferromagnetic material scattered on the surface by magnetizing the specimen is adsorbed to the scratch. Observe this and detect scratches.
-
TD230 -
TESTEX Testing Equipment Systems Ltd.
This machine is a professional equipment for sample dyeing and washing test at room temperature in weak alkaline environment or conventional conditions, for fabrics, fiber or yarn. Ultra quiet design and greatly enhances levelness of specimen dyeing.
-
Premier Electrosystems
Premier Electrosystems' Ball Pressure Test is used to determine dimensional stability under stress at elevated temperatures. It analyses the relationship between the degree of deformation and the temperature when the test specimen is subjected to a constant load.
-
Shimadzu Corp.
This is a structural fatigue testing machine for researching the dynamic behavior of full-size or model structures by applying repeated loads. The actuator that supplies the loads to the specimens can be installed on load frames, reaction floors, reaction walls, etc.
-
Shimadzu Corp.
These plastic molding material grips are used when tensile testing plastics with dimensions specified in JIS K6911, plastic molding materials, and JIS K7113 No 3 specimens, as well as those shown in the diagram below.