Showing results: 376 - 390 of 1178 items found.
-
CHA20 -
dfv Technologie
This digital chronometer enables the user to measure the time between two pulses generated either by a dry contact, a TTL input or an AC or DC voltage.
-
Renesas Electronics Corp.
Renesas' communications product portfolio includes a synchronizing pulse width modulating (PWM) current mode controller for subscriber line interface circuits (SLICs).
-
Pundit PL-200 -
PASI srl
The Pundit PL-200 is a best-in-class Ultrasonic pulse velocity (UPV) test instrument to examine the quality of concrete and other materials such as rock, wood and ceramics.
-
4B Components Ltd.
The SpeedMaster with Pulse Pilot provides independent, real time, and complete verification of an entire speed monitoring system to ensure that alarms and shutdowns are working as expected.
-
VX Instruments GmbH
The timer functionality is able to generate pulses or frequency signals with a defined number and duration.The counter function analyzes digital signals in terms of duration and number.
-
DG009-M1 -
Teledyne Defence & Space
Many advanced EW receivers, particularly those associated with ECM jamming systems, do not require the high resolution frequency information associated with a DFD or IFM based receiver. This is typically the case where a single pulse present within a broad frequency band is required to be detected and instantaneously down-converted to an IF band.TDS manufactures a range of Frequency Activity Detectors (FADs) also known as Activity Detection Units (ADU) which perform frequency measurement of an RF pulse and output data in as little as 15ns. The basis of these products is TDS’s ability to produce high performance broadband channelisers and integrated detectors. These devices are ideal for receivers which must operate in very high pulse density environments.
-
mks Ophir
Pyroelectric sensors for measuring repetitively pulsed energy at up to 25 kHz. These sensors use a pyroelectric crystal that generates an electric charge proportional to the heat absorbed. The response time of the pyroelectric sensor depends on the time it takes for the heat to enter the crystal and heat it up. For metallic type pyro detectors, this time is tens of μs and thus the metallic type can run at a high repetition rate. For the BF and BB type, the response time is milliseconds with a correspondingly lower repetition rate. Ophir pyroelectric detectors have unique and proprietary circuitry that allow them to measure long pulses as well as short pulses and work at a high duty cycle, i.e. where the pulse width is as much as 30% of the total cycle time.
-
TM500 -
T&M Tools Limited Co
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
Insight Product Company
Insight Product Company offers pulse injection-locked IMPATT amplifiers for pulse ESR/EPR experiments. Pulsed injection-locked amplifier incorporates IMPATT diode, ferrite input/output isolators, circulators, and pulse modulator. Only DC power supply, RF input signal, and external trigger signal are required to operate the amplifier. Output phase noise parameters are very close to the noise parameters of the input RF signal.
-
MC -
Holding Informtest
The MC mezzanine module is designed to receive external commands and issue synchronization pulses on the TTLTRG line (for VXI and other devices) and the LVDS line (for LXI devices).
-
Cannon -
Del Mar Photonics, Inc.
Cannon provides a turnkey portable source of broadband laser pulses without reqiring any user-adjustments to the fiber coupling. Optical Spectrum - 1000 - 1900 nm.
-
TQ-5300 -
Ono Sokki
TQ-5300 Torque meter, used with the TQ-2000 series High-stiffness torque detector, can convert the pulse output of the detector to digital torque value and analog voltage output.
-
TECHNO-AC
Cable fault location by electromagnetic and acoustic methods (with high-voltage pulse transmitter, which is not included into the set)Detection of insulation deterioration on cables by contact and non-contact methods
-
Insight Product Company
Insight Product Co. 's S-band, 2.856 GHz, klystron provides up to 6.0 MW of output pulse power, and has two regimes of operation.
-
ADLINK Technology Inc.
Pulse train motion controllers generate high-frequency digital signals to control servo motors and steppers, matching performance and precision positioning of high-performance servo amplifiers.