Millimeter Wave
extremely High Frequency in the range of 30 to 300 gigahertz.
See Also: Wave, Extremely High Frequency, Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Shock wave, mmWave, MW
-
product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Video Inspection Scope
BK3000
• Integrated 8.5 mm high-res imager allows for ease of use and ensures the product is always ready to go. Imager is resistant to dust, dirt, and water ingress for 30 minutes at depths of up to 3 meters.
-
product
Kelvin Test Contactor/Probe Head
Gemini
At 3.22 mm test height, the Gemini™ Kelvin test contactor is an excellent all-around spring probe with low inductance, high bandwidth, and excellent current-carrying capacity. The device under test (DUT) side tip design accurately maintains its 100 µm spacing for the life of the probe. Customers report typical probe life of 500 k to 800 k package insertions, or over 2M touchdowns at wafer-level test. The offset tip allows manageable board layout with a board-side spacing of 0.4 mm.Gemini Kelvin probes and contactors provide a first-rate solution that effortlessly makes reliable, true Kelvin contact for high-volume final test of both singulated packages and wafer-level devices. Gemini Kelvin is an ideal solution for devices such as power controllers, A-D and D-A converters, power amplifiers and audio and video circuits.
-
product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H150-1
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Probing Solutions
ES62X-CMPS
The ES62X-CMPS compact manual probe station is a rugged wafer probing solution designed for high reliability, compact size and low investment cost. It enables manual wafer level measurements up to 300 mm wafers. The probing station can also be used for TLP, HMM, HBM, LV-Surge, RF, S-parameter and DC-measurements. Micro positioners with vacuum as well as magnetic base can be attached. The chuck has a vacuum interface for the wafer and is electrically isolated. Multiple 4 mm connectors can be used to connect a voltage potential to the wafer backside.
-
product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1F-4.5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Ultrasound Detector/Recorder
D500X
The D500X Mk II is as easy to use and provides the same features as the classic D500X, with the following exceptions:*It does not include an internal microphone. Instead it ships with an external microphone which is either directly connected to the microphone jack or through an extension cable (sold separately). The microphone jack is an XLR type so no adapter cable is required.*It is powered by 4 C type batteries which last roughly three times longer than the AA batteries used in the classic D500X.*The jack for external power is a standard 2.5 mm DC power jack for easy connection.
-
product
ESD Tester
PurePulse
PurePulse is a flexible and efficient ESD tester for HBM, TLP, MM and HMM. Its 2-pin style setup reduces tester parasitics, it captures waveform data and can be automated to test thousands of pins without the need for a test fixture. Our PurePulse system was designed from the ground up to be customized to meet your testing needs, take a look at the features below and schedule a demo with us to learn more.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
CCA-003 Battery Probes
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 670Overall Length (mm): 17.02
-
product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25T79-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1C1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Thermal Warpage and Strain Measurement Tool
PS200S
The TherMoir PS200S is a metrology solution that utilizes the shadow moir measurement technique combined with automated phase-stepping to characterize out-of-plane displacement forsamples up to 150 mm x 200 mm. With time-temperature profiling capability, the TherMoir PS200S captures a complete history of a sample's behavior during a user-defined thermal excursion.
-
product
BMA Connectors
Pasternack BMA connector category includes several models. BMA connector products in this category are built to precise industry specifications. Like the other over 40,000 RF, microwave and millimeter wave components from Pasternack, this BMA connector series is in-stock. Not only are these connectors in BMA series in stock, but they also will ship the same day as purchased.
-
product
Ultra High 3.83 (109.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-72I15-10
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74T75-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Kilowatt Hour Meters
DIN96 energy meters for measuring kWh of individual machines or complete systems. Manufactured to BS5685, IEC521 with a class accuracy of 1% to IEC1036, and supplied in a 96 x 96 mm DIN case. The kilowatt hour meter has a 7 digit non resettable mechanical counter. Pulsed output is available to send to PLC’s data loggers and computers. Analogue mA output is also available.
-
product
1U-4U SlimBox For CompactPCI
1U to 4U rack-mounted enclosure with 482.6 mm (19") mounting brackets (may be offset approximately 100 mm to the rear). Two backplane slots can fit in each 1U of chassis height (standard 0.8” pitch) with rear plug I/O options. Enclosure cooling from left to right with EMC and ESDcompatible configuration. Optional: Hot swap-compatible power supply units with current splitting for redundancy operation (2U). Conforms to IEEE 1101.1/10/11,
-
product
Hardy Shaker
HI-903
This is our top of the line Hardy Shaker. It provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting vibration tests easier. Tests can be conducted on multiple vibration transducers, and then the saved data can be transferred via USB Flash Drive to be displayed in an automated and customizable report using an Excel template on your computer. In manual mode, the vibration test level and test frequency can be set from 7 Hz to 10,000 Hz. The high accuracy instrument can display the vibration level in terms of g’s peak, velocity peak (in/sec or mm/s) or displacement peak-to-peak (mils or µm). The unit can support payloads up to 800 grams (see frequency limits in the manual). A built-in display reads the output sensitivity, which can be stored in memory. Complete testing sequences and data can be stored in memory for each tested sensor, the unit logs the data on the spot or stores it for later use. For testing of heavy transducers or at high frequencies, the HI-903 automatically corrects the sensitivity calculation for the effects of transducer mass loading. A built-in self-test program checks for accuracy of all calculations. The HI-903 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3B
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25I40-12
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1C2S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Handheld Water Quality Meters
LAQUA EC210
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
product
Receiver, I2 Micro ICon, 168 Position, Fully Loaded With Twin Female Contacts (610 138 200)
310130101
The i2 Micro iCon receiver is a one piece connector capable of holding up to 168 QuadraPaddle contacts. QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. This i2 receiver is fully loaded with twin female contacts, QuadraPaddle Part # 610 138 200. Accessories such as keying pin kit, protective cover, and strain relief are available.
-
product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-1R2S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Portable Wattmeter (Unity Power Factor)
Supreme Instrument Laboratories
The Principle of working is Electo-dynamometer type for Wattmeters. Portable dynamometer type single phase Single element Wattmeter housed in laminated wooden cabinet size 235 mm length x 200 mm width x 180 mm height, with detachable lid, black bakelite panel fitted with anti-parallax mirror scale, knife edge pointer, rubber footings, carrying handles, locking arrangements.
-
product
Manual Fixture Kit
230371 – CMCSK-02-01
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″





























