Showing results: 2011 - 2025 of 2507 items found.
-
M9393A -
Keysight Technologies
9 kHz to 8.4 GHz, 14 GHz, 18 GHz, or 27 GHz Frequency extension to 50 GHz (minimum frequency of 3.6 GHz) with Option FRX40 MHz (standard), 100 MHz, or 160 MHz analysis bandwidth, and optional wideband IF output with Option WB1Up to 4 time-synchronous channels
-
Insight Product Company
Insight Product Company offers Golay cells that detect electro-magnetic waves at terahertz frequency ranges from 0.0375 to 996 THz.
-
XVR16 6U -
Abaco Systems Inc
The newest Intel technology offers integrated graphics plus a memory controller, with quad-core processing up to 2.4 GHz — all in one device. Coupled with the Intel QM87 Express Chipset this provides an unmatched level of I/O bandwidth for both on-board and off-board functions.
-
Fairview Microwave Inc.
RF detectors from Fairview Microwave are available with N Type or SMA connector series inputs and BNC or SMA connectors for outputs. Fairview RF detectors are zero bias Schottky diode and have negative video out. These zero bias Schottky diode detectors for RF have a minimum frequency between 10 MHz and 2 GHz and maximum frequency range between 2 GHz and 26.5 GHz.
-
42-788-132-T -
Pickering Interfaces Ltd.
The 40-788-132-T (PXI) and 42-788-132-T (PXIe) are dual failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
K11644A -
Keysight Technologies
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
N5295AX51 -
Keysight Technologies
The N5295AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
S970241B -
Keysight Technologies
Add pulsed-RF measurement capabilities to your P50xxB Streamline series vector network analyzer
-
S960250B -
Keysight Technologies
Add pulsed-RF measurement capabilities to your E5081A ENA-X vector network analyzer.
-
85564A -
Keysight Technologies
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
L2051XA -
Keysight Technologies
Frequency range of 10 MHz – 6 GHzLAN connectivity with a wide dynamic range of -70 to +26 dBm for small signal measurementsFast real-time measurement of 50,000 readings/secReal-time measurement with zero dead time to ensure every single continuous pulse is measuredAverage mode time-selectivity function allows full dynamic range for average and time selectivity average power measurementsInternal zero and automatic calibration saves time and reduces measurement uncertaintyA BenchVue software license (BV0007B) is now included with your instrument. BenchVue makes it simple to connect, control instruments, and automate test sequences
-
85514A -
Keysight Technologies
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
85032F -
Keysight Technologies
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
S970240B -
Keysight Technologies
Add pulsed-RF measurement capabilities to your P50xxB Streamline series vector network analyzer
-
S930702B -
Keysight Technologies
S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.