Showing results: 1741 - 1755 of 2524 items found.
-
42-788-132-T -
Pickering Interfaces Ltd.
The 40-788-132-T (PXI) and 42-788-132-T (PXIe) are dual failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
K11644A -
Keysight Technologies
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
N5295AX51 -
Keysight Technologies
The N5295AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
S930905B -
Keysight Technologies
The S930905B spectrum analysis adds high-performance microwave spectrum analysis to the N522xB/N523xB/N524xB PNA network analyzer family up to 50 GHz.
-
S970241B -
Keysight Technologies
Add pulsed-RF measurement capabilities to your P50xxB Streamline series vector network analyzer
-
S960250B -
Keysight Technologies
Add pulsed-RF measurement capabilities to your E5081A ENA-X vector network analyzer.
-
85564A -
Keysight Technologies
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
L2051XA -
Keysight Technologies
Frequency range of 10 MHz – 6 GHzLAN connectivity with a wide dynamic range of -70 to +26 dBm for small signal measurementsFast real-time measurement of 50,000 readings/secReal-time measurement with zero dead time to ensure every single continuous pulse is measuredAverage mode time-selectivity function allows full dynamic range for average and time selectivity average power measurementsInternal zero and automatic calibration saves time and reduces measurement uncertaintyA BenchVue software license (BV0007B) is now included with your instrument. BenchVue makes it simple to connect, control instruments, and automate test sequences
-
85514A -
Keysight Technologies
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
85032F -
Keysight Technologies
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
S970240B -
Keysight Technologies
Add pulsed-RF measurement capabilities to your P50xxB Streamline series vector network analyzer
-
S960907B -
Keysight Technologies
The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
-
S930702B -
Keysight Technologies
S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S930705B -
Keysight Technologies
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
L2067XA -
Keysight Technologies
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.