Cesium Standards
A primary frequency standard in which electronic transitions between the two hyperfine ground states of cesium-133 atoms control the output frequency.
-
Product
Standard Pitch Spring Probes
-
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
Product
Frequency Standard Products
-
The ES-110 generates a stable source of 10 MHz using GPS (Global Positioning System) satellites as a reference. If frequency distribution is needed, we offer the ES-210, a Quad 1x6 1/5/10 MHz Distribution Amplifier. The ES-210 provides four independent 1x6 Frequency DAs in a single rack-mount enclosure. The ES-410 is a four output version of the ES-110. The ES-410 was introduced and won Radio Magazine's Best of Show Award at the 2016 NAB Show.
-
Product
Standard RF Fixture
-
The standard RF fixture supports both pulsed and non-pulsed operation. It employs SMA input/output connections. For RF output powers over 10W, an N-type connector may be used to replaces the SMA connector because of its power-handling capability.
-
Product
Programmable S/R Standard & Simulator
5300
Simulator
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
Product
Standard Amplifiers
-
Teledyne RF & Microwave, a Business Unit of Teledyne Microwave Solutions (TMS), supplies catalog and custom RF and microwave amplifier designs for aerospace, defense, and industrial applications. These standard amplifiers, originally designed by Teledyne Cougar, provide both excellent stability and cascadability.
-
Product
Intex Beam Gauge & Standard Contacts
-
Developed to measure both internal and external diameters and lengths, the Intex gauge's aluminium extrusion beam gives it a rigid yet lightweight quality, making it ideal for shop-floor environments. The simple release of a locking thumbscrew enables the gauge's measuring direction to be changed quickly and easily.
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Standard Signal Isolating Amplifier
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation and conversion of standard signals. Calibrated switchable inputs and outputs 0/4 ... 20 mA and 0 ... 10 V signal duplicator with two electrically isolated outputs.
-
Product
Standard Voltage 37 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Automated Temperature Resistance Standard
-
Measurements International Ltd.
Exceptional Stability, Cost-effectiveness, Performance-based Results, 10 Ω, 25 Ω, 100 Ω, 200 Ω, 400 Ω and 1000 Ω Internal Standards, Built-in Temperature Chamber for Optimal Performance.
-
Product
Standard Voltage 50 Pin D-Type Connectors for Pickering
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2SB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00)
P3325-1
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
Custom Optical Components and Standards
-
With the amount of applications that optical components have, no one could hope to have the perfect component for every possible scenario. For this reason, APPLIED IMAGE makes easy the process of designing, building, and delivering custom components to our customers. Our engineering process is designed to produce the best parts in the industry and more importantly, the best component for your specific needs. The APPLIED IMAGE experience will cover the project with expert engineers from start to finish. Use the form below to start the conversation for checkerboard and dot arrays, stage and image analysis micrometers, reticles and machine vision components.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF120
-
Lifasa - International Capacitors, SA
Accessories: Differential protection
-
Product
Open Standard Module (OSM)
ROM-2860
-
Advantech ROM-2860 OSM 1.1 Computer-on-Module is powered by Qualcomm QCS6490/5430 SoC which includes up to Arm v8 Cortex® in combination with Andreo GPU 643 and Andreo VPU 633 graphics engine. It provides PCIe, USB 3.2, Giga Ethernet, MIPI-CSI, I2C, SPI, GPIO, PWM and eDP, DP, MIPI-DSI display for embedded applications.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
Product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
-
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1C-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
Product
Electron Multiplication (EM) Standard Image Sensors
-
EM (Electron Multiplication) is a technology that uses on-chip gain in the charge domain to effectively eliminate read noise from an image sensor. This enables advanced ultra-low light applications that require extreme sensitivity at fast frame rates. Examples include life science applications such as single molecule detection, super resolution microscopy and spinning disk confocal microscopy along with physical science applications such as nanotechnology imaging, Bose Einstein condensates and soft X-ray spectroscopy, and astronomy applications such as adaptive optics and lucky imaging. The inclusion of an additional conventional output allows further flexibility for applications such as true 24 hour surveillance.
-
Product
Standard Normally Open
-
Is an optically coupled element that combines a GaAs infrared LED on the input side with anormally-open MOS FET on the output side to realize an excellent cost performance.The small, thin package and high sensitivity of this element makes it ideal for battery-driven mobile devices, and its small offset voltage at power-on and good linearity are also make it suitable for controlling micro analog signals.
-
Product
IEC60335 Standard Electrical Temperature Tester
CX-w15
-
Shenzhen Chuangxin Instruments Co., Ltd.
Standard Test corner/room conform to IEC60335-1:2004. and GB4706.1-2005. can be used to the temperaturetest of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions.
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HF-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Standard Gain Horn Antennas
-
Linear polarized Broadband Horn Antenna (Brass with Plastic mounting body) for Receive and Transmit Applications.
-
Product
15T Standard Running Line Monitor
RLM15T-3.0-S
-
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
Product
BF-Series Standard Plus Models
-
The E-DRIV® BF-Series standard plus models feature a selectable Double Hit Mode for soft joint applications and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The BF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.