- TEAM SOLUTIONS, INC.
product
Current Loop 20 MA Constant Current SI-module With Optical Isolation
MXTTY
Current loop 20 mA constant current (active, passive) SI-module with optical isolation.
-
product
Automatic Hysteresis Graph Test System
DX-4DMT
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
product
Material Science Laboratory Instruments
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
product
Fluxmeter
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
product
Magnet Tester
H30 Series
AlmiCo, Ferrite, NdFeB, SmCo5, Sm2Co17 magnets are tested and their B-H and MH loops are plotted using Ferrites India make H30 Series hysteresis loop tracers. The complete system consists of a magnetizer to magnetize the test piece, an electromagnet and a BH Loop Plotter. Magnets with coersivity as high as 13 kOe and more can also be tested.
-
product
B-H Analyzer
SY-8218 / SY-8219
Soft magnetic components made of ferrite play an important role in electric components as they are used in a broad range of applications from low-frequency applications such as yokes for micromotors, to high-frequency applications such as flyback transformers, deflecting yokes, high-frequency transformers and magnetic heads. In actual operation, these magnetic components display characteristics different from DC magnetic characteristics or characteristics measured with an LCR meter.
-
product
Loop Antenna
ZHX7-0.009-200-1486
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
Loop Meters
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation ind...show more -
product
Line Loop Tester
8455
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
product
Antenna, Active Loop
EM-6876 | 9 KHz – 30 MHz
The Electro-Metrics EM-6876 Active Loop Antenna is used with EMI Receivers and Spectrum Analyzers with 50 ohm input and covers the frequency range of 9 kHz to 30 MHz.
-
product
mA Loop Calibrators
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Open Loop Current Sensor
C03 50A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in systems for industry and commerce as well as in communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Loop Antennas
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
Single Loop Controller
1400+
The 1400+ controller is an evolved product from the West N4100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Loop Meter
MZC-310S
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
Radiating Loops
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
product
Open Loop Current Sensor
K03
The K03 series is a current sensor based on the Hall effect. It enables the electronic measurement of direct, alternating or pulsed currents as well as their combinations with galvanic separation between primary (high current) and secondary circuits.
-
product
mA Loop Calibrators
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
product
Ground Loop Transformer - VT11
Humdinger
A wideband CCTV video-isolating transformer (ground loop transformer) used for the reduction of longitudinal mains induced hum. For high-resolution video signals and 'down the cable' telemetry it is essential that all components in the signal path are of sufficient bandwidth to pass the full frequency range of both signals with minimal distortion.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
Short Circuit Loop Impedance Meter
AMZC-306
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.