Ground Leakage
is unwanted current flowing to ground.
-
Product
Electrical Safety Multi-Analyzer
TOS9300 Series
-
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Electrical Safety Testers
-
A high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Hipot Line Testers
-
The newest product of our Hipot Line Testers, the UL Listed HT-S series hipot now comes with an adjustable ground continuity test in range of 0.08 - 1.50 , and Auto-offset for test leads up to 1.00 . Performs 0-2000 AC Hipot Test. Neutral/Hot to Ground Leakage current test up to 20 mA AC. Easy to use and connect. Ships complete with cables, manual, and a Calibration Certificate.
-
Product
Ground-Fault Detectors for Ungrounded Systems
-
Early detection of ground faults on ungrounded systems allows critical systems to remain online while faults are identified and resolved. By continuously monitoring the system's insulation resistance, Bender's ground-fault detectors can provide early indication of both immediate and trending ground faults before leakage current may be of concern.
-
Product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
-
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
Product
Iron Core Earth Tester
-
Weshine Electric Manufacturing Co., Ltd
Transformer iron core grounding current tester is a high-precision clamp meter specially designed for measuring AC leakage current, current and voltage. Large diameter (80×80mm) can clamp φ80mm cable, or 96mm×4mm flat steel ground wire, suitable for cables Leakage detection and transformer grounding flat steel leakage measurement.
-
Product
Electrical Safety Analyzer
19032
-
Chroma Systems Solutions, Inc.
Our Electrical Safety Analyzers combine Hipot, Insulation Resistance ( IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC, and Dynamic Function Tests. Savings can be up to 50% of production line space by not having to purchase and rack several safety test instruments. It also increases efficiencies of electrical safety testing and reduces associated labor costs.
-
Product
Earth Leakage Relay
-
Nippen Electrical Instruments Co.
NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.
-
Product
Earth Ground Testers
-
It is critical for facilities to have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. To ensure a reliable connection to earth, the International Electrical Testing Association specifies ground electrode testing every three years.
-
Product
Ultrasound Leakage Tester
-
Measures both the conductivity of the cleaning medium and the leakage current of the ultrasound transducer.
-
Product
Personal Grounding Tester
PGT120
-
Electronic test apparatus for checking personnel grounding systems such as electrostatic wrist straps and conductive footwear. The unit is equipped with two separate measuring circuits and is therefore capable of checking wrist straps and footwear separately or in parallel. The test result is signaled visually, acoustically (only if error is detected) and via contacts.
-
Product
Leakage Current Testers
-
For general-use electrical devices Built-in non-medical use networks For rated currents of up to 20A For automatic testing on production lines, etc.
-
Product
Ground Set Tester
-
Self-contained, portable convenienceThis tester provides an easy way for an electric utility to check the resistance in protective grounding sets used by line personnel.
-
Product
Battery Ground Detector
BGD
-
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
Product
SF6 Leakage Detector
GDWG-IV
-
GDWG-IV SF6 Gas Leak Detector is infrared type leak detector. It is color LCD display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It's a good device suitable for power supply department, installation and overhaul unit, power test institute.
-
Product
AC/DC Leakage Current Tester
228
-
Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.
-
Product
Neutral Grounding Resistors
NGR
-
Neutral Grounding Resistors (NGRs) are used to limit the fault current for safety of equipment and personnel in industrial systems.
-
Product
Protector Conductor Test / Ground Continuity Test / Ground Bond Test
-
Testing the protective conductor is indispensable for assemblies, devices and systems of protection class I because it reduces the risk of life-threatening electrical accidents.The test checks whether the protective earth (PE) fulfils the criteria specified in the standards and can correctly discharge the current occurring in case of a fault.The ground continuity test checks whether the protective earth conductor is connected continuously to all metallic enclosure parts that can be touched by the user. The test can be carried out with low currents and voltages (simple continuity test).
-
Product
Capacitor Leakage Current Meter
DU2316/2317
-
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
Product
Guardian Ground Bond Tester
19572
-
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
Product
Duct Air Leakage Tester
6900
-
Kanomax has developed the most advanced Duct Air Leakage Tester (DALT) for commercial duct systems. It’s designed to be simple to use, accurate, and extremely convenient. The instrument provides step-by-step duct leakage test configuration and automated leakage testing based on the SMACNA HVAC Air Duct Leakage Test Manual, and is accurate to ±2.5% of reading. Though built tough with an on-board, powerful motor, the DALT 6900 is very easy to transport on its pneumatic tires and leaves little to no footprint on the job site.
-
Product
Ground Fault Monitors
IFT
-
In most industrial settings, ground faults can cause significant damage. Since these leaks are unavoidable in almost all industrial environments, our ground fault monitors allow you to quickly and easily find the source of the leak before a major problem occurs and damages your equipment. The IFT-120 is designed to help you rapidly locate ground faults.
-
Product
Ground Fault Finder
FST-JD200 DC
-
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
Product
Ground Bond Tester,
266
-
Our 266 Model makes Ground Bond / High Continuity Testing simple with 60 Amps of current to satisfy your toughest NRTL standard. With an intuitive interface that allows you to set-up a test in seconds and practical security settings, our 266 can easily be deployed in both laboratory and production line environments. Ensure every Ground Bond Test is accurate with our Milliohm offset function.
-
Product
Ground Weather Analytics
HELIOS
-
L3Harris Geospatial Solutions, Inc
Microclimates are on the rise, and as a result, there are extreme deviations of wind, snow, fog and visibility even over short distances. Organizations of all sizes need hyperlocal ground information and weather data to enhance operational efficiencies and make better decisions that can save time, money, property and even lives.
-
Product
Leakage Current Alarm Signaler
MPU-1
-
MPU-1 is dedicated to control (measure) leakage current in AC, low and medium voltage power networks. It is designed to make measurements, which results define network's safety condition for leakage current. The device enables to set limit for maximum safe value of flowing leakage current and for values above this limit visual and sound alarm is activated.





























