Ground Leakage
is unwanted current flowing to ground.
-
Product
Electrical Ground Support Equipment:
EGSE
-
Keysight provides a variety of configurable test systems for satellites and satellite flight hardware; including Solar Array Simulators, Battery Simulation and Conditioning, RF signal simulation and analysis as well as fully custom solutions.
-
Product
Ground Fault Location
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
Product
AC Leakage Clamp Meter
SK-7820/SK-7825
-
Wide range from 40mA to 100A AC,Conductor dia. : φ24mm max (SK-7820), φ40mm max (SK-7825)AC voltage measurement.Vibration alert comparator.(The function to show the comparator result by buzzer and vibration which is convenient innoisy surroundings.)
-
Product
Aeronautical Ground Earth Station Emulator
GES
-
Square Peg Communications Inc.
Ground Earth Station (GES) emulator provides a simple and flexible means of testing the operation of Aeronautical Earth Stations (AESs) and end-to-end applications for the Inmarsat Classic Aero service, without the expense of airtime charges. It can be used to test basic AES functionality, including Aero I/H+ and Aero H voice calls, and data transfer applications such as ACARS.
-
Product
Ground Fault Analyzers and Detectors
-
The Model 760 detects and locates accidental ground faults on both energized and de-energized power circuits including single phase, three phase, and DC ungrounded systems.
-
Product
Mini AC Leakage Current Clamp Tester
M-100+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・18mmφCT window and ultra compact size.・Least affection from the external magnetic field.・The special alloy is used for core material that resists the rust over long period of use and ensures stable,high accurate measurements with very slight influence from aging.
-
Product
Analog AC Leakage Current Clamp Tester
MCL-350
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High accuracy analog display with strong taut band meter.*3 years long battery life.*Meter lock function and data output for recorder.*Filter rejection for high frequency noise
-
Product
Ground EMI Filters
-
High-frequency signals on ground is never good news - it interferes with normal operation of equipment and creates electrical overstress (EOS). However it is easy to block propagation of EMI on ground by installing highly-effective ground EMI filtes in ground lines. Our unique patent-pending ground EMI filters provide very low impedance for DC and mains' power while effectively blocking propagation of high-frequency currents throughout facility or equipment ground. Ground filters meet safety standards, as well as ANSI/ESD S6.1 and ANSI/ESD S20.20.
-
Product
Ground Fault Locator
GFL-1000
-
The GFL-1000 ground fault locator is used to pinpoint faulty grounding where electrical cables have breakage and lost to the ground. The GFL-1000 is recommended by NERC PRC-005-2 to inspect for unintentional grounds for VLA, VRLA and NiCad batteries every four calendar months. Included software allows for data management analysis.
-
Product
AC & DC Analog Leakage Meters
2108 EL
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Four functions : DC current, AC current, AC+DC current, and ACV measurement.● Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.● 200uA full scale value.● ±2.5% full scale value accuracy.● Built-in overload protection circuit.● Robust, compact and easy to carry.
-
Product
Leakage Current Clamp Tester
M-1141
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency(fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
Product
Earth Ground Meters
-
The earth tester determines ground resistance for both specific and ohm resistances. The earth tester is powered by batteries and have a clock timer function (3 minutes), Data-Hold function, a 3 ½ positions LCD display and their dimensions are 163 x 100 x 50 mm. Resistance ranges come from 20, 200 to 2000 ohms. They have a resolution of 10 / 100 mΩ / 1 Ω. The earth tester measure resistance by means of a constant reverse current (approx. 800 Hz, 2 mA). To measure ground voltage a rectifier is used (5 kΩ/V aprox. 40...500 Hz). The earth tester PKT-2630 series have a small format as well as multiple functions.
-
Product
Ground Fault Protection Monitors
-
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
Product
Leakage Current Tester
-
Premier's Leakage Current Tester (also known as Hipot Tester) simulates the effect of a person touching exposed metal parts of a product and detects whether or not the leakage current that would flow through the person's body remains below a safe level.
-
Product
Earth Ground Clamp Meter
T2000
-
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
Product
Earth Ground Tester
1625-2
-
The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes.
-
Product
UAV Ground Test Equipment (LTS)
MS 1103
-
*Checks integrated functionality of UAV*During integration checks it performs the functions of the Ground Control Station*Interface with Target Group Set (TGS)*Information is decoded and displayed in the display panel
-
Product
GAOTek Three-Channel Leakage Current Tester
GT00YB00ZV
-
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.
-
Product
Resistance Grounded Systems (HRG/LRG)
-
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
Product
Ground Leads Continuity Tester
-
Weshine Electric Manufacturing Co., Ltd
1. The new power supply technology is adopted in the grounding down lead conduction tester.2. It has the characteristics of small size, light weight, large output current, good repeatability, strong anti-interference ability and protection function. 3. The whole machine is controlled by single chip microcomputer, which has a high degree of automation. 4. The instrument has high precision and easy operation. The maximum current is 10A.
-
Product
Guardian Ground Bond Tester
19572
-
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
Product
AC Current / Leakage Digital Clamp-on Tester
MCL-500DFN
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
MCL-500DFN AC Current / Leakage Digital Clamp-on Tester
-
Product
Ground-Fault Products for Solidly Grounded Systems
-
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
Product
AC Leakage Current Tester
229-2
-
Testing for dangerous small leakage currents is easy with the Simpson Model 229-2 Leakage Current Tester. For use in appliance field service, in the lab, or in production, the 229-2 approximates the human threshold of perception in detecting hazardous AC leakage current. The 229-2 comes with test leads with alligator clips, manual and batteries.
-
Product
ATEX / FM Approved Grounding Clamps, Cables and Reels
Cen-Stat Static Grounding Clamps
-
Static grounding systems like the Earth-Rite range combine interlock control and visual indication to verified ground connection points and offer the highest levels of protection over electrostatic ignition risks. However, equipment specifiers may select passive grounding devices, like single pole clamps, to ground and bond plant equipment.