Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Power Frequency Transducer
TDF
-
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Low Frequency Vibration Signal Conditioner
-
A compact Signal Amplifier to make optimal signal processing being connected with the Servo type Accelerometers. It is used for Vibration Acceleration Measurement, Waveform Observation, for various Analysis in combination with the AC Voltage Meter, Oscilloscope, FFT Analyzer respectively. Furthermore, Voltage signals from the Microphones or Sound Level Meters can be output to the instruments like Recorders along with the Vibration Signals.
-
Product
Rugged GPS Time & Frequency Reference
VersaSync
-
VersaSync is a high-performance GPS master clock and network time server that delivers accurate, software-configurable time and frequency signals in harsh environments, including GPS-denied areas. Now with M-Code!
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1J-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HF-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3E
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
-
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
UL Standards Testing and Certification
-
If you are selling your product in the United States, your product must comply with the applicable nationally accepted UL standards. F2 Labs can evaluate and test your product, help you through the UL certification process and enable you to certify your product to the UL requirements through a Nationally Recognized Test Lab (NRTL).
-
Product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1C1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
NanoCD Standards (NCD)
-
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-INS-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Response Function
FRF
-
FFT Spectral Analysis. Frequency Response Function (FRF) is a commonly used measurement type of the Dynamic Signal Analyzer. FRF is defined as the ratio of response i.e. acceleration, velocity, or displacement with respect to the excitation force which is the reference.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1P-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2D
General Purpose Probe
Current Rating (Amps): 5Average Probe Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64Resistance (mOhm): 35
-
Product
Digital High Frequency Surge Testers
C Model
-
These Digital High Frequency Surge Testers are the ultimate in ruggedness & durability. Fourteen / sixteen gauge steel construction and mobility on 6" heavy duty rubber wheels makes it a favorite for use in harsh industrial environments. The performance of PJ's exclusive/unique High Frequency Technology is capable of testing the integrity of any turn-to-turn insulation, including low inductance windings.
-
Product
BF-Series Standard Models
-
The E-DRIV® BF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The BF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Cable Assembly, Receiver, High Frequency, 36", 10 SMA Plugs
540153010212
Cable Assembly
Cable Assembly, Receiver, High Frequency, 36", 10 SMA Plugs
-
Product
SINE Sinusoidal Single Frequency Gratings
-
Our SINE Sinusoidal Single Frequency transmittance patterns have proved to be very useful for specialized MTF Measurement as well as for such applications as moirè contouring. They are made on film base material with a nominal thickness of 0.175mm. This material is polyester and tends to be somewhat birefringent. The harmonic modulation values are generally 3% or less.
-
Product
600MM 24In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles, IP54 Standards
DL406
-
Advance Plus Trading Co., Ltd.
Model Number: DL406 Key Specifications/Special Features: 600MM 24INCH Digital Level with level bubbles,LCD bright backlight display, IP54 standards 1. 600mm 24 inch level with 2 bubbles, 600*28*64mm(L*W*H), net weight: 520g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13.Handshank design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
Product
Standards Source Instrumentation
-
PXI Arbitrary Waveform and Programmable Function Generators as well as DC source cards and a precision standards module.
-
Product
Intex Beam Gauge & Standard Contacts
-
Developed to measure both internal and external diameters and lengths, the Intex gauge's aluminium extrusion beam gives it a rigid yet lightweight quality, making it ideal for shop-floor environments. The simple release of a locking thumbscrew enables the gauge's measuring direction to be changed quickly and easily.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Ultra-Low Frequency Raman Spectrometer Down to 10 cm-1
Modular TeraHertz Raman Spectrometer
-
HORIBA’s modular terahertz modular Raman spectrometer extends the spectral range of a measurement to < 10 cm-1. Consisting of an Ondax SureBlock™ module fiber coupled to HORIBA’s iHR320 imaging spectrometer, this custom system provides an affordable option for macro-Raman measurements close to the laser line. Below are Stokes and anti-Stokes spectra of elemental sulfur recorded with this system.





























