  • MODEL M25 - Ground Continuity Test Instrument Performs ground continuity tests in full compliance with BSI, VDE and IEC. Measures AC resistance from Chassis of Device Under Test (DUT) to power-cord ground lead - 0 to 0.15 ohm
    Rod-L Electronics
  • ZSGCT - Ground / Earth Continuity Tester Trip, Test On, Test Off Output test current through high current wire and Earth pin of 3 pin socket.
    ZEAL Services
  • GF-30AC - High Current Ground Continuity Tester The GF-30AC is a production line workhorse. This unit delivers a constant AC current while checking impedence. This unit protects product under test as internal current limiting prevents over-current excursions. Test results indicated by red and green LED's, audible buzzer on failure V=IRtual voltage sense circuit compensates for any resistance in both the test leads and AC power cord.
    Compliance West USA
  • P/N 1756 - Circuit Tester and Tool Ground Continuity Tester Receptacle-circuit testers have three neon indicating lights that provide a convenient way to test three-wire, 115VAC, single-phase and polarized outlets. This tester also checks for correct wiring, reverse polarity, open-ground, open-neutral, open-hot, hot-and-ground-reversed and hot-on-neutral/hot-unwired. Additionally, receptacle-circuit testers are U.L.-rated.
    Woodhead Molex
  • 61-920 - Ground Resistance Clamp Meter Larger Clamp Size (1.25"). Backlight. Ground resistance (0.1 to 1200?). Ground leakage current to 30A. Ground continuity loop test. Audible alarm. Data Storage 
    IDEAL Industries
  • 61-030 - Continuity Tester Checks continuity of dead circuits, ground on conduit systems and identifies wires in multi-wire cables. Light signal indicates completed circuit. Bulb in end can serve as flashlight. Pocket clip functions as probe. Removable 4-ft test lead with alligator clip  
    IDEAL Industries
  • M25, 30, 35 - Ground Continuity Tester - 25, 30, 35 AMP Production / Quality Assurance Testing - Performs ground continuity tests in full compliance with BSI, VDE and IEC. Measures ground continuity from ground to the power cord ground pin of the DUT. Interface enables interconnection to any ROD-L Hipot & Leakage testers to form a complete automatic test system.
    Rod-L Electronics
  • R1L-C - Ground Resistance Test System The Model R1L-C is a Ground Resistance Ohmmeter designed to measure grounding system resistance as well as soil resistivity, over ranges from 2 Ω to 20 kΩ full scale. These resistance measurements correspond to soil resistivity from as low as 2 Ω-cm to as high as 600,000 Ω-cm. The R1L-C is capable of Wenner, Fall of Potential, 62% methods as well as bond and continuity measurements. Two, three and four are standard for this instrument.
    TEGAM
  • Ground Resistance Test System The Model R1L-C is a Ground Resistance Ohmmeter designed to measure grounding system resistance as well as soil resistivity, over ranges from 2 Ω to 20 kΩ full scale. These resistance measurements correspond to soil resistivity from as low as 2 Ω-cm to as high as 600,000 Ω-cm. The R1L-C is capable of Wenner, Fall of Potential, 62% methods as well as bond and continuity measurements. Two, three and four are standard for this instrument.
    TEGAM
  • AV-25V-GC1-05 - DIELECTRIC and CONTINUITY TESTERS ( HI-POTS ) This tester is designed for testing equipment wiht a line cord which can be plugged directly to the tester. The continuity test is to determine whether the ground wire of the line-cord is well connected to the metal frame of the unit under test.
    Criterion Instruments
  • 3630 - Battery Powered Continuity Tester Designed to test any type of non-live electrical circuit. Track down broken wires, bad grounds and blown fuses quickly. Features and Benefits. Comes with AAA Alkaline battery. Ergonomic, slim designed clear handle. 12-foot red coil cord. Low voltage replaceable bulb. Molded strain relief. Heavy-duty stainless steel probe with insulated shaft. Heavy-duty clip with positive soldered connection.?
    OTC
  • M100DC - DC Hipot Test Instrument Performs concurrent ground continuity test. ARC and OVERCURRENT detection circuits. Fast discharge of Device Under Test (DUT) and other test standards
    Rod-L Electronics
  • DGC-1000A - Clamp-on Ground Resistance Tester Accurate ground resistance measurement from 0.025 to 1500 Ohms. TRMS current measurement including leakage current. Continuity beep if the resistance is lower than 40.00 Ohms 
    Amprobe Test Tools
  • 382252 - Earth Ground Resistance Tester Kit Includes all hardware necessary to measure earth ground in 3 ranges from 20 to 2000Ohm. Large dual display with backlight. Test Hold function for easy operation. Automatic Zero adjustment. AC/DC Voltage, Resistance, and Continuity. Auto Power off, Overrange and low battery indication. Complete with test leads, 2 auxiliary earth bars, carrying case, protective rubber holster and six 1.5V AA batteries.
    Extech Instruments
  • 4680, 4680B - Clamp-On Earth / Ground Resistance Tester Non Contact Ground Resistance Measurement No Auxiliary Electrodes Needed Recording / 116 Sets of Memory Ground Resistance Measurment 0.025 Ω ~ 1500 Ω Suitable for Ground Wire upto Ф 23mm (Model 4680) Suitable for Ground Wire upto Ф 35mm (Model 4680B) Leakage Current (0.200mA ~ 30.00A)(Model 4680) Leakage Current (0.200mA ~ 35.00A)(Model 4680B) Programable High & Low Alarm Programmable Data Logging Auto Range Continuity Loop Test Auto Power Off
    Meco Instruments
  • ML11 - Test Loads Each test load provides two test operations for verifying functionality of a Hipot Tester and Ground Continuity Tester. Provides two ground continuity tests (open and short) at up to 35 amperes maximum
    Rod-L Electronics
  • ML12 - Test Loads Each test load provides two test operations for verifying functionality of a Hipot Tester and Ground Continuity Tester. Provides two ground continuity tests (open and short) at up to 35 amperes maximum
    Rod-L Electronics
  • HP2000 - AC/DC Hipot Tester Meets UL, CSA, CE, IEC and all other international safety agency requirements. 1 Button Testing - No setup required, just plug right in! Easy to identify PASS / FAIL (anyone can operate!) Also performs the Low Current Ground Continuity test, at the same time! Custom ?Universal? receptacle accepts both 120V and 240V plugs. 
    Educated Design &
  • CMG30 - ELECTRICAL SAFETY TESTER This instrument is made for ground continuity resistance measurements (also called ground bond testing, bonding test), which is the first of the 4 tests required by the Electrical Safety Testing std.
    Sefelec
  • 2745A - ELECTRICAL SAFETY TESTER Dedicated for production line or other environments, Premier series is synonymous of low cost but high benefits. AC/DC dielectric strength test (also called hipot test, dielectric strength test), insulation measurement (megohmmeter mode), ground continuity (also called ground bond testing). PLC control for start/stop and test result output
    Sefelec
  • LC-90 - LED Display Lan Cable Tester Test pin configuration. - Verify cable continuity, open, short and miss-wired. - Auto and manual scan function. - Ground wire test. - Locked status wire function. - Buzzer sound warning for detective wire detected.
    Tenmars Electronics
  • M450LT - Leakage Current Tester Performs leakage current tests in compliance with IEC 601, UL 544, UL 2601 and other medical and non-medical standards. Add Rod-L Hipot & Ground Continuity testers to build a complete modular automatic test systerm
    Rod-L Electronics
  • Clare B433R - Earth Bond Tester The B433R is a cost effective, simple to use, rugged, earth bond test system suited to manufacturing or laboratory environments. This earth / ground bond tester can deliver a test current of 25A through a resistance/impedance of 0.1½ from a low voltage a.c. source. This earth/ ground bond tester meets the general requirements of the majority of international test standards that relate to system earth continuity or ground bonding measurement.
    Seaward
  • SMG500 - ELECTRICAL SAFETY TESTER Designed as well for laboratories as for complex production lines, SMG structure can easily be customized to always better fit customer needs, and fulfill the 3 tests required by the Electrical Safety. AC/DC dielectric strength test (also called hipot test, dielectric strength test), insulation measurement (megohmmeter mode), ground continuity (also called ground bond testing)