Filter Results By:

Products

Applications

Manufacturers

Showing results: 661 - 675 of 1177 items found.

  • Modular Mounts

    M-SWITCH - M³ Measurement Solutions Inc.

    The M-Switch series of adjustable, modular mounts are designed to redirect a horizontal interferometric set-up to a vertical one. This vertical orientation can help reduce distortion effects commonly found from clamping, and reduce alignment time. There are 4 primary versions of hardware designed to enable testing of mirrors, windows, lenses and lens assemblies. Holding of the part under test can be done with a variable 3 arm mount (for flexibility) or our kinematic mount (for high volume). Reference mirrors can be supplied with a variety of flatness and coating specifications to match your application needs.

  • Bulk Density Apparatus

    21-27 - Testing Machines, Inc.

    Bulk density apparatus is testing equipment used to measure the bulk density property of powder, granules and other “divided” solids, especially used in reference to mineral components (soil, gravel, sand), chemical substances, (pharmaceutical), plastics like polyethylene (hdpe or mdpe) pvc, polystyrene etc, or foodstuff and any other masses of granular or particulate matter. Bulk density is defined as the mass of many particles of the material divided by the total volume they occupy. The total volume includes particle volume, inter-particle void volume and internal pore volume.

  • Fully automated Crude and Detergent Fibre analysis

    Fibertec™ 8000 - FOSS A/S

    The Fibertec 8000 is a fully automated system for determination of crude fibre, detergent fibre and related parameters according to standard reference 'crucible' methods such as Weende, van Soest and other recognised methods. Approvals for the crucible method include ISO, EEC, AOAC, AOCS. The Fibertec 8000 provides unrivalled accuracy, the highest safety and the lowest operator time of any fibre solution.Parameters: Crude fibre, neutral detergent fibre, acid detergent fibre, acid detergent lignin. Sample types: Raw materials and finished products in Feed and Agriculture.

  • 1203c Broadband RF Distribution

    Precise Time and Frequency, Inc.

    The ptf 1203C Broadband RF Distribution amplifier provides high performance frequency references for laboratory or system use.The ptf 1203C uses two stages of input signal buffering to distribute the input signal to 12 separate outputs, and insure maximum isolation between individual output signals.

  • Radiating Comb Generators

    TBCG1 - TekBox Singapore Pte. Ltd.

    The TBCG1 is a radiating comb generator with an internal antenna and a base frequency of 100MHz. It radiates a comb spectrum characterized up to 6GHz. The comb generator is built and characterized to serve as a rough reference for testing radiated noise measurement set ups in anechoic chambers, TEM/GTEM cells, shielded chambers, etc.

  • Hydrogen Frequency & Time Standard

    CH1-1033 - VREMYA-CH JS Company

    The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.

  • Bench Multimeters

    Fluke Calibration

    Fluke Calibration meters have the precision and versatility to handle the most demanding measurements, on the bench or in a system. These instruments are easy to use and offer excellent value that makes them an ideal solution for many applications. Standards laboratory meters include: Reference multimeters; precision digital multimeters; bench multimeters

  • Mezzanine System

    5174 - Abaco Systems Inc

    The 5174 provides two major functions, serving as a precision Voltage Controlled oscillator board and a variable frequency source board. These features can be use together or independently. As a variable frequency source, the 5174 provides a high-resolution variable clock source that is based upon a reference clock supplied by the ECM carrier.

  • Data Acquisition

    HEAD acoustics GmbH

    Sound, vibration, status and reference variables, voice, audio data and more: HEAD acoustics is setting the standard in data acquisition. We offer flexible systems for mobile applications and operation in the laboratory. Our data acquisition systems can also be expanded flexibly using various software and hardware modules.

  • Imaging Photometer & Colorimeter

    LumiTop 4000 / 2700 - Instrument Systems Optische Messtechnik GmbH

    The patented optical design permits simultaneous measurement of all three sensors in one shot. The accurate spectral measurement is used as a live reference and transferred to the complete display area of the camera. This makes for extremely short measurement times and all relevant optical tests are conducted in a single test station.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Analog Tank Test Kit

    4108 - M. C. Miller Company

    The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.

  • Active Type Hydrogen Frequency

    CH1-1003M - VREMYA-CH JS Company

    Hydrogen frequency and time standard Ch1-1003M is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main applications: – national time and frequency services; – ground stations for tracking and control of satellite radio navigation systems; – radio interferometry with extra long base.

  • RF & Microwave Modules And Instruments

    SHF Communication Technologies AG

    In digital high speed test and measurement, a perfect clock signal is crucial for the generation of low jitter reference test signals. A SHF Synthesized Signal Generator (Synthesizer) used as a clock source can operate over several decades of frequency and is an essential part of any high speed test and measurement environment.

  • Current Sensing

    Texas Instruments

    voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.

Get Help