Filter Results By:

Products

Applications

Manufacturers

Showing results: 796 - 810 of 1177 items found.

  • Development Boards

    Advantech Co. Ltd.

    Advantech Development boards provide a schematic software & reference to reduce design effort at the development stage. Development Boards have been designed in order to allow customers to verify the functions of COM, text carrier board problems and support COM series. Advantech has designed a Development Board which can be used to test carrier board problems and support COM series, and Qseven, ETX / XTX form factors.

  • CAD / BOM Translation Software

    ProntoTEST-FIXTURE - Unisoft Corp.

    In minutes the Unisoft ProntoTEST-FIXTURE software translates CAD and Bill of Materials (BOM) files into real reference designators, netlists, X/Y component pin geometries, values, tolerances, part numbers, etc. This data is then used by Test Engineers to program their ATE (Agilent/Hewlett Packard "board & board x/y", Teradyne "ipl", Genrad ".ckt"), MDA, and flying probe test equipment and design the "Bed of Nails" test fixtures.

  • Integrated Potentiostat and Multiplexer

    EmStatMUX8 - PalmSens BV

    Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.

  • Chemiluminescence 03 Analyzer

    Model T265 - Teledyne Advanced Pollution Instrumentation

    The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.

  • Signal Conditioners

    General Purpose - Encore Electronics, Inc.

    Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.

  • Trace-Level UV Fluorescence SO2 Analyzer

    Model T100U - Teledyne Advanced Pollution Instrumentation

    The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.

  • 0.1Hz-3.7GHz Frequency Counter

    FC-3000 - MCH Instruments Co.,Ltd.

    Features:*Frequency measuring range: 0.1Hz to 100MHz in A input, 80 MHz to 3.0GHz in C input.*Period,Total and RPM measurement for input A*9 Digit display with 0.01mHz resolution in 1 Sec (By Ext.Reference signal).*RS-232C serial interface function for communication with computer.*High sensitivity Extemal reference input function(>=1.5Vrms).*Peciprocal technique for high resolution at low counting frequencies .*Self check function executed to perform a automatic self diagnosis of various counter function.*Push-scanning for selecting Function and Gate time.*Low-pass filter(100KHz,-3dB)installed for removing noise signsl in low frequency measuring.*AC/DC coupling function(Selectable AC/CD Coupling)*10:1 Input Attenuation(Selectable×1/×10 Attenuator)*Data hold function

  • 2210A & 2211A Quartz Frequency Standards

    Precise Time and Frequency, Inc.

    The ptf 2210A Quartz Frequency Standard has been designed to provide a highly stable and spectrally pure frequency reference for applications requiring the ultimate in short term frequency performance.The instrument contains a double oven controlled stress compensated (SC cut) quartz crystal oscillator (OCXO) to give the ultimate in performance.Ideal for laboratory or system use, the unit provides good stability performance at lower cost and with improved phase noise.

  • Mid-Range Gas Filter Correlation CO Analyzer​

    Model T300M - Teledyne Advanced Pollution Instrumentation

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.

  • Optical Meters

    Gamma Scientific Inc.

    The Gamma Scientific range of light meters includes handheld and benchtop models.  Configuration options include a wide range of sensors and calibrations in units including:  Luminous Flux (lumens) or Radiant Flux (Watts),  Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr),  Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr),  or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.

  • Portable Three-Phase Meter Site Analyzer

    RW-30X / RW-31X - Radian Research, Inc.

    RADIAN RW-30/31X Meter Site Analyzers deliver comprehensive three-phase field testing and site analysis utilizing the Radian Research RX Xytronic series reference standard as its measurement engine. The RW-30/31X provides for testing meters with integrated, precision, true three-phase voltage and current sources or using customer’s load. Choose the RW-30/31X NS (no source) model to test using customer’s load only.

  • Hydrophone

    RESON TC4013 - Teledyne Marine RESON B.V.

    ​The TC4013 offers a usable frequency range of 1Hz to 170kHz and a high sensitivity relative to its size. It further-more provides uniform omnidirectional sensitivities in both horizontal and vertical planes up to high frequencies.The TC4013 is an excellent transducer for making absolute sound measurements and calibrations within a broad frequency range. It can also be applied as an omnidirectional reference projector.The overall characteristics makes TC4013 extremely applicable for laboratory as well as industrial uses.​

  • Phase Noise Analyzer

    NXA-26 - Eastern-Optx

    This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.

  • Vibration Calibrator

    SV 111 - SVANTEK Sp. z o.o.

    SV 111 vibration calibrator is the State of the Art instrument designed for human vibration measurements according to ISO 8041. The design of the calibrator is based on the triaxial reference accelerometer and microprocessor controlled shaker. These both features assure excellent stability of the calibration levels and their frequency independently from mass of the testing object, like also indicate improper test object fixing by monitoring of shaker vibration in all three axis simultaneously.

  • Portable Battery Coolant/Glycol Refractometer with ATC (°C)

    Extech RF41 - Extech Instruments Corporation

    Refractometer measures the Propylene/Ethylene Glycol freezing point from -50 to 0°C and the Specific Gravity of battery acid from 1.11 to 1.30 and provides a quick reference of battery charge condition. Requires only 2 or 3 drops of solution for fast and accurate readings. Automatic Temperature Compensation provides repeatable measurements on an easy to read scale. Prism and lens with a simple focus adjustment. Includes carrying case and calibration screwdriver.

Get Help