Showing results: 601 - 615 of 1177 items found.
-
Delta Elektronika BV
Is the unidirectional flow or movement of electric charge carriers (which are usually electrons). The intensity of the current can vary with time, but the general direction of movement stays the same at all times. As an adjective, the term DC is used in reference to voltage whose polarity never reverses.
-
DCZCT-20CDHL -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Low DC current measurements.*DC1mA~200mA*High accuracy.*±1%F.S ±10mV*Least influence of magnetization.*Less than DC1mA in current level*Convenient +5V single polarity power supply.*Reference voltage (Vref) terminal is equipped.
-
Renesas Electronics Corp.
These are the standard reference voltage source widely used by the feedback circuits of switching power supplies. Compared to the Zener diode, which is a discrete product, a shunt regulator has much better voltage precision because voltage control is carried out as an IC.
-
TB41 -
Calmet Smart Calibration Devices
The Calmet TB41 Four Position Meter Test Bench is used for calibration and simultaneously testing up to four single and three phase electromechanical and electronic acitve and reactive electricity meters with accuracy referenced to an internal reference meter (class 0.02% or 0.04%).
-
MTE Meter Test Equipment AG
Single- and three-phase, standardized and individual test systems are covering all legal metrological test requirements for simple meters, high precision multifunction meters, smart meters and reference standards. Flexible and modular system components for the optimal customer orientated solution.
-
TS33 -
Calmet Smart Calibration Devices
The Calmet TS33 portable test system consists of a three-phase reference meter of accuracy class 0.02%, 0.04% or 0.1% and an integrated three-phase current and voltage source up to 3x120A/600V. The TS33 is designed for analysis of complete metering installations and local mains conditions.
-
Rocky Mountain Laboratories, Inc.
FTIR Analysis is used to analyze organic materials. Bulk and small particle materials can be analyzed. FTIR microscopy allows for the identification of particle as small as 10 µm. Determination of unknown materials is facilitated by spectral matching to a library of over 250,000 reference spectra.
-
EchemLab XM -
Ametek Scientific Instruments
EchemLab XM includes a reference grade potentiostat and frequency response analyzer (FRA). EchemLab XM has a built-in 100 V high voltage amplifier which can be used for not only for compliance measurements but also for high voltage cell polarization. This is useful in many high solution resistance applications, for example in organic electrochemistry. In addition to high voltage, power boosters can also be integrated to combine high current and high voltage in many specialized plating applications.
-
ZED-F9T (Qwiic) -
SparkFun Electronics
The SparkFun GNSS Timing Breakout offers a unique entry into SparkFun's geospatial catalog featuring the ZED-F9T GNSS receiver from u-blox. The ZED-F9T provides up to five nanosecond timing accuracy under clear skies with no external GNSS correction making it perfect for applications where timing accuracy is imperative. Need an extremely accurate time reference to maximize the efficiency of your IoT network of 5G devices? The ZED-F9T GNSS Timing Breakout could be the perfect solution.
-
Brandywine Communications
Brandywine offers a wide range of high quality, state of the art signal timing distribution amplifiers, all with very low phase noise. These precision timing signal distribution amplifiers offer a variety of time and frequency signals and interface formats including IRIG A, IRIG B, Have Quick, 1PPS, as well as low phase noise reference frequencies. All of our distribution amplifiers feature dual inputs with automatic failover and multiple independently buffered outputs.
-
SmallCellCORE-5G -
CommAgility Limited
SmallCellCORE-5G provides a 5G Core (5GC) for 5G small cells and private networks. SmallCellCORE-5G joins CommAgility's existing 5G stack, PHY and reference chain software, to create an integrated solution with the company's hardware platforms.With SmallCellCORE-5G, developers can now build their 5G network with a complete set of hardware and software from CommAgility – already tested and integrated. Development is quicker and easier, and risk is reduced by working with a proven solution, backed up by CommAgility's expert, global support.
-
FMC216 – HPC -
Sundance Multiprocessor Technology Ltd.
The FMC216 is a sixteen-channel DAC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC216 provides sixteen D/A 16-bit 312.5Msps (2.5Gsps with x8 interpolation) channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC216 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled capable.
-
UHPS -
RARA Electronics Corporation
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
NCT-500 -
ShinewayTech
ShinewayTech NCT-500 Network Cable Tester,Functions ranging from ISO / OSI reference model physical layer, link layer, network layer multiple detection. One machine in hand, which can quickly locate network faults and determine the link quality.
-
Apogee Instruments, Inc.
Linear OutputThe Apogee chlorophyll concentration meter is calibrated to measure chlorophyll concentration in leaves with units of mol of chlorophyll per m2. This eliminates the problems with relative indexes of chlorophyll concentration.For reference and comparison purposes, the Apogee meter also outputs relative units [CCI or SPAD] if desired.For details see: Parry, C., Blonquist Jr., J.M., & Bugbee, B. 2014. In situ measurement of leaf chlorophyll concentration: analysis of the optical/absolute relationship. Plant, Cell and Environment 37:2508-2502.