Filter Results By:

Products

Applications

Manufacturers

Showing results: 46 - 60 of 81 items found.

  • Working Electrodes for Flow Cell

    ALS Co., Ltd

    Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.

  • Portable XRF Analyzer

    GoldXpert - Olympus Corp.

    XRF is a widely used, proven, and accepted method of chemistry analysis and determination of purity and fineness of precious metals. XRF analysis is a multielemental testing alternative that is quicker and less expensive than fire assay and chemical tests. XRF provides on-the-spot analysis of your silver, platinum, and PGM metals and impurities, making it an easy way to boost customer confidence and ensure dealer reliability.

  • Ring Disk Electrode

    ALS Co., Ltd

    This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.

  • Environmental Test Chamber

    Lisun Electronics Inc.

    The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor

  • HUMIDITY Sensor

    DSHS07 - Smartec bv

    The Smartec humidity sensor is a two terminal capacitor, which increases in value as water molecules are absorbed into its active polymer dielectric. The capacitor plates consist of a base plate and a water permeable platinum top plate. The sensor will be delivered with gold-plated lead wires attached. Besides the active dielectric, polymers give protection to the base plate, prevent polarisation and pinholing and generally ruggedise the sensor so that it can be used in a wide range of hostile environments.

  • Relays

    PO3000 - Mors Smitt Group

    Various contact materials are available to meet particular circuit conditions and operating environments, including pure silver, palladium and platinum, and silver-nickel and gold-nickel alloys. PO3000 relays can be configured to operate at voltages from 5V to 250V with operate delays up to 100mS and release delays up to 500mS. Mors Smitt also offer a comprehensive service/repair, re-test and re-certification service for PO3000 type relays where this can provide an economical alternative to purchasing new relays.

  • Resistance Thermometers

    WIKA Alexander Wiegand SE & Co. KG

    Resistance thermometers are equipped with platinum sensor elements which change their electrical resistance as a function of temperature. In our range of products you will find versions with connected cables as well as versions with connection heads. A temperature transmitter can be installed directly in the connection head. Furthermore, in the WIKA product portfolio, in addition to threaded resistance thermometers, flanged resistance thermometers or process resistance thermometers, you will also find the right measuring insert for your application.

  • 16-Channel VME RTD/Resistance Input Module

    V410 - Highland Technology, Inc.

    The V410 is a 6U VME module that provides sixteen independent analog inputs that may be used to read RTDs, thermistors, and other similar resistive sensors. It can also read cryogenic diodes. Users may set input range and adjust other settings at VMEbus speed, and depending on the range selected the microprocessor will do the necessary calculations and output voltage, resistance, or temperature. Temperature conversion is available for 100Ω and 1000Ω, series 385 and 392, platinum RTDs.

  • Temperature Calibration

    Process Instruments Inc.

    Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.

  • Reference Thermometers

    ThermoWorks

    Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.

  • Chilled Mirror Transmitter

    DewTrak II - Edgetech Instruments

    The DewTrak II uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance thermometer to accurately measure that temperature. Outputs include 4 to 20mA, 0 to 5 Vdc, or 0-10Vdc and an RS232 serial port as well as electrically isolated relay contacts.

  • Bluetooth® Enabled ORP/REDOX & Temperature Pen

    UltrapenX2™ PTBT3 - Myron L Company

    *Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof

  • Conductivity Electrode

    ALS Co., Ltd

    As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.

  • Cross Flow Cell

    ALS Co., Ltd

    Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.

  • Thermal Conductivity Gas Analyzer

    CI2000-RQD - Shanghai ChangAi Electronic Science & Technology Co.,Ltd

    Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure.

Get Help