  • Climate Chamber

    ICH - Memmert GmbH + Co.KG

    Its excellent temperature and humidity homogeneity positions the climate chamber ICH in the international top league of stability test chambers. Thermal transfer to the interior whether heat or cold is guaranteed through a large-area air jacket on four sides. Thanks to its hermetically sealed interior, the climate chamber ICH does not consume any water once the setpoints have been reached, provided that the door is not opened. Two high-grade platinum temperature sensors with mutual monitoring guarantee interruption-free long-term operation even if one sensor should fail.

  • Low Constant Temperature Trough

    DRK6691 - Shandong Drick Instruments Co., Ltd.

    Drk6691 small low constant temperature trough is a special product designed for small Abbe refractometer, supporting the use of. It has many advantages such as constant speed, constant temperature, small volume, low noise and convenient operation and so on , so it is a higher price products. This product adopts the technology of the one chip computer, PID selftuning regulation technology;adopts imported platinum resistance temperature (Pt100), so it has high precision of temperature control and temperature fluctuation is small; adopts the semiconductor refrigeration technology, so that it consists of advantages of fast refrigeration, no noise.

  • Temperature Standards

    ITS-90 - Fluke Calibration

    The defining instruments of the ITS-90 (International Temperature Scale of 1990) are Standard Platinum Resistance Thermometers (SPRTs) and ITS-90 fixed-point cells. SPRTs are calibrated in fixed-point cells to provide the highest possible temperature accuracy. Primary standards offered by Fluke Calibration include: long-stem SPRTs; capsule SPRTs; triple point of water cells; metal fixed-point cells; maintenance baths and maintenance furnaces for fixed-point cells; standard resistors.

  • Solar Panel Reach-in Chambers

    ENX48Solar Panel Reach-in Chambers - ESPEC North America, INC.

    Your first choice for a medium-size test chamber for PV module testing is ESPEC's ENX48.These models provide a variety of performance capabilities to meet maximum or minimum change rates in IEC or UL test standards. Incorporated are the features of our smaller Platinum and Global-N lines. The refrigeration systems of these models utilize modern, high performance scroll compressors that allow a small footprint while allowing unparalleled service access.

  • Vigilant Aircraft Hygrometer

    137 - Edgetech Instruments

    The Edgetech Instruments Model 137 Vigilant Aircraft Hygrometer is a rugged, shock mounted military qualified instrument used for the primary measurement of dew point in flight or in installations with existing flow, such as wind tunnels.It features a miniature remote dew point sensor employing a platinum resistance thermometer, and has 15 feet of interconnecting cable to the control unit. Precision calibration units for the linear analog outputs are included.

  • Precision Thermometer

    F252 - ASL

    ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.

  • Reference Thermapen®

    ThermoWorks

    Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.

  • 8 Channels, RTD Measurement

    RT1 - North Atlantic Industries

    The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.

  • Electrochemical (Molecular Electronic Transfer) Motion Sensor transducers

    The Molecular Electronic Transfer Technology

    The basic design of the MET transducer, shown in Figure 1. The transducer is contained in a channel, 1, of a sensor filled with a specially prepared electrolytic solution. It consists of four fine platinum mesh electrodes, two anodes, 2, and two cathodes, 3, separated by thin, microporous ceramic or polymer spacers 4. Such an assembly is held together by a housing 5. To measure the motion of the fluid, it must be converted into an electrical signal. One way of achieving this is by using the convective diffusion of the ions in the electrolyte. At the heart of a MET device are inert electrodes at which a reversible redox reaction occurs, which does not involve either plating of a metal or evolution of a gas.

  • Automatic surface tension Meter

    SKZ1013A - SKZ Industrial Co., Ltd

    Automatic surface tensiometer, made up of high precise and stable force measurement system, microcomputer control system, platinum plate (ring) measurement device, is compact in design, simple and reliable in structure, easy in operation (automatic/manual). It features net weight in whole range (one-key minimum clearing), whole range automatic calibration, good repeatability, accurate and reliable test result as well as liquid crystal display of test data with S232C output interface.

  • Solar Panel Compact Walk-in Chambers

    ENX112 - ESPEC North America, INC.

    The ENX112 chambers provide a test chamber large enough for testing full-size PV modules in the least amount of floorspace. Can be use for panels 1.2m x 2m or larger.These models provide a variety of performance capabilities to meet maximum or minimum change rates in IEC or UL test standards. Incorporated are the features of our smaller Platinum and Global-N lines. The refrigeration systems of these models utilize modern, high performance scroll compressors that allow a small footprint while allowing unparalleled service access.

  • Dual MAX31865 PT-100 RTD to Digital Breakout

    SEN-30202-PT100 - Playing With Fusion Inc

    Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.

  • Tracking Index Test Apparatus

    CX-L19 - Shenzhen Chuangxin Instruments Co., Ltd.

    It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass.  Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.

  • Galvanic DO Sensor

    Model 20 - Reliant Water Technologies

    The Model 20 Galvanic DO Sensor utilizes proven galvanic sensing technology – without a question the most accurate and reliable DO sensing technology ever developed. The pure platinum cathode makes the sensor incapable of being poisoned by other gases often found in impure waters, such as hydrogen sulfide. This sensor utilizes the only DO sensing technology that is successful in continuous de-nitrification monitoring and control applications. It is also the only sensor design that can be used continuously in very violent pure liquid oxygen injection systems. Complete systems are supplied with over 5 years of sensor electrolyte and membranes.

  • Micro Melting Point Instrument

    DRK8026 - Shandong Drick Instruments Co., Ltd.

    Determine crystal melting point of the substance to make sure its purity. Mainly used for determining the meltingpoints of medicine,dyestuff,spice and other organic crystal compounds.Using photoelectric automatic detection, Dot matrix LCD display picture technology, digital keyboard input, and has the initial melting, final weld automatic display,automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperature system uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.